7,442 research outputs found

    Characterisation of respiratory motion extracted from 4D MRI

    Get PDF
    Nuclear Medicine (NM) imaging is currently the most sensitive approach for functional imaging of the human body. However, in order to achieve high-resolution imaging, one of the factors degrading the detail or apparent resolution in the reconstructed image, namely respiratory motion, has to be overcome. All respiratory motion correction approaches depend on some assumption or estimate of respiratory motion. In this paper, the respiratory motion found from 4D MRI is analysed and characterised. The characteristics found are compared with previous studies and will be incorporated into the process of estimating respiratory motion. © 2013 SPIE

    Predicting respiratory motion for real-time tumour tracking in radiotherapy

    Full text link
    Purpose. Radiation therapy is a local treatment aimed at cells in and around a tumor. The goal of this study is to develop an algorithmic solution for predicting the position of a target in 3D in real time, aiming for the short fixed calibration time for each patient at the beginning of the procedure. Accurate predictions of lung tumor motion are expected to improve the precision of radiation treatment by controlling the position of a couch or a beam in order to compensate for respiratory motion during radiation treatment. Methods. For developing the algorithmic solution, data mining techniques are used. A model form from the family of exponential smoothing is assumed, and the model parameters are fitted by minimizing the absolute disposition error, and the fluctuations of the prediction signal (jitter). The predictive performance is evaluated retrospectively on clinical datasets capturing different behavior (being quiet, talking, laughing), and validated in real-time on a prototype system with respiratory motion imitation. Results. An algorithmic solution for respiratory motion prediction (called ExSmi) is designed. ExSmi achieves good accuracy of prediction (error 4−94-9 mm/s) with acceptable jitter values (5-7 mm/s), as tested on out-of-sample data. The datasets, the code for algorithms and the experiments are openly available for research purposes on a dedicated website. Conclusions. The developed algorithmic solution performs well to be prototyped and deployed in applications of radiotherapy

    Visually guided respiratory motion management for Ethos adaptive radiotherapy

    Get PDF
    PURPOSE: Ethos adaptive radiotherapy (ART) is emerging with AI-enhanced adaptive planning and high-quality cone-beam computed tomography (CBCT). Although a respiratory motion management solution is critical for reducing motion artifacts on abdominothoracic CBCT and improving tumor motion control during beam delivery, our institutional Ethos system has not incorporated a commercial solution. Here we developed an institutional visually guided respiratory motion management system to coach patients in regular breathing or breath hold during intrafractional CBCT scans and beam delivery with Ethos ART. METHODS: The institutional visual-guidance respiratory motion management system has three components: (1) a respiratory motion detection system, (2) an in-room display system, and (3) a respiratory motion trace management software. Each component has been developed and implemented in the clinical Ethos ART workflow. The applicability of the solution was demonstrated in installation, routine QA, and clinical workflow. RESULTS: An air pressure sensor has been utilized to detect patient respiratory motion in real time. Either a commercial or in-house software handled respiratory motion trace display, collection and visualization for operators, and visual guidance for patients. An extended screen and a projector on an adjustable stand were installed as the in-room visual guidance solution for the closed-bore ring gantry medical linear accelerator utilized by Ethos. Consistent respiratory motion traces and organ positions on intrafractional CBCTs demonstrated the clinical suitability of the proposed solution in Ethos ART. CONCLUSION: The study demonstrated the utilization of an institutional visually guided respiratory motion management system for Ethos ART. The proposed solution can be easily applied for Ethos ART and adapted for use with any closed bore-type system, such as computed tomography and magnetic resonance imaging, through incorporation with appropriate respiratory motion sensors

    1082 Free-breathing single-shot DENSE myocardial strain imaging using deformable registration

    Get PDF
    Free-breathing scans are often desirable in patients who find breath-holding difficult. We present a new approach for free-breathing myocardial strain imaging with displacement-encoding (DENSE) [1]. It acquires images with a single-shot sequence and removes respiratory motion using deformable registration

    Event-by-event non-rigid data-driven PET respiratory motion correction methods: comparison of principal component analysis and centroid of distribution

    Get PDF
    Respiratory motion is a major cause of degradation of PET image quality. Respiratory gating and motion correction can be performed to reduce the effects of respiratory motion; these methods require motion information, typically obtained from external tracking systems. Various groups have studied data-driven (DD) motion estimation methods. Recently, a data-driven respiratory motion estimation method was established by calculating the centroid of distribution (COD) of listmode events, which was then used with event-by-event respiratory motion correction (EBE-MC), and showed results comparable to those with an external motion tracking device. The EBE-MC method only corrected for rigid motion, so that non-rigid components still contributed to motion-induced blurring. A nonrigid respiratory motion correction (NRMC) was later developed to overcome this problem, but was only evaluated using signal from an external monitor. Thus, it is desirable to further develop data-driven to achieve the best respiratory motion correction results. 
 We evaluated 2 data-driven respiratory motion detection methods, COD and Principal Component Analysis (PCA), by comparing the extracted motion trace to that acquired by the Anzai system in dynamic studies with two tracers. PCA was chosen as a preliminary study indicated that it produced stable results than other DD methods. We then developed and performed DD-EBE-NRMC using either COD- or PCA-derived respiratory motion information. Data-driven correction results were compared with Anzai-based results. For all tested studies, both COD and PCA showed good-to-excellent match with Anzai signals, with PCA showing a higher correlation with Anzai signals. The DD-EBE-NRMC results showed that both COD and PCA provide comparable image quality improvement as the Anzai-based correction. Although COD showed a lower correlation with Anzai than PCA, COD-based NRMC results are comparable to those of PCA, both of which showed great reduction in motion-induced blurring

    Optical flow-based vascular respiratory motion compensation

    Full text link
    This paper develops a new vascular respiratory motion compensation algorithm, Motion-Related Compensation (MRC), to conduct vascular respiratory motion compensation by extrapolating the correlation between invisible vascular and visible non-vascular. Robot-assisted vascular intervention can significantly reduce the radiation exposure of surgeons. In robot-assisted image-guided intervention, blood vessels are constantly moving/deforming due to respiration, and they are invisible in the X-ray images unless contrast agents are injected. The vascular respiratory motion compensation technique predicts 2D vascular roadmaps in live X-ray images. When blood vessels are visible after contrast agents injection, vascular respiratory motion compensation is conducted based on the sparse Lucas-Kanade feature tracker. An MRC model is trained to learn the correlation between vascular and non-vascular motions. During the intervention, the invisible blood vessels are predicted with visible tissues and the trained MRC model. Moreover, a Gaussian-based outlier filter is adopted for refinement. Experiments on in-vivo data sets show that the proposed method can yield vascular respiratory motion compensation in 0.032 sec, with an average error 1.086 mm. Our real-time and accurate vascular respiratory motion compensation approach contributes to modern vascular intervention and surgical robots.Comment: This manuscript has been accepted by IEEE Robotics and Automation Letter

    PREDICTION OF RESPIRATORY MOTION

    Get PDF
    Radiation therapy is a cancer treatment method that employs high-energy radiation beams to destroy cancer cells by damaging the ability of these cells to reproduce. Thoracic and abdominal tumors may change their positions during respiration by as much as three centimeters during radiation treatment. The prediction of respiratory motion has become an important research area because respiratory motion severely affects precise radiation dose delivery. This study describes recent radiotherapy technologies including tools for measuring target position during radiotherapy and tracking-based delivery systems. In the first part of our study we review three prediction approaches of respiratory motion, i.e., model-based methods, model-free heuristic learning algorithms, and hybrid methods. In the second part of our work we propose respiratory motion estimation with hybrid implementation of extended Kalman filter. The proposed method uses the recurrent neural network as the role of the predictor and the extended Kalman filter as the role of the corrector. In the third part of our work we further extend our research work to present customized prediction of respiratory motion with clustering from multiple patient interactions. For the customized prediction we construct the clustering based on breathing patterns of multiple patients using the feature selection metrics that are composed of a variety of breathing features. In the fourth part of our work we retrospectively categorize breathing data into several classes and propose a new approach to detect irregular breathing patterns using neural networks. We have evaluated the proposed new algorithm by comparing the prediction overshoot and the tracking estimation value. The experimental results of 448 patients’ breathing patterns validated the proposed irregular breathing classifier

    Characterization of Respiratory and Cardiac Motion from Electro-Anatomical Mapping Data for Improved Fusion of MRI to Left Ventricular Electrograms

    Get PDF
    Accurate fusion of late gadolinium enhancement magnetic resonance imaging (MRI) and electro-anatomical voltage mapping (EAM) is required to evaluate the potential of MRI to identify the substrate of ventricular tachycardia. However, both datasets are not acquired at the same cardiac phase and EAM data is corrupted with respiratory motion limiting the accuracy of current rigid fusion techniques. Knowledge of cardiac and respiratory motion during EAM is thus required to enhance the fusion process. In this study, we propose a novel approach to characterize both cardiac and respiratory motion from EAM data using the temporal evolution of the 3D catheter location recorded from clinical EAM systems. Cardiac and respiratory motion components are extracted from the recorded catheter location using multi-band filters. Filters are calibrated for each EAM point using estimates of heart rate and respiratory rate. The method was first evaluated in numerical simulations using 3D models of cardiac and respiratory motions of the heart generated from real time MRI data acquired in 5 healthy subjects. An accuracy of 0.6–0.7 mm was found for both cardiac and respiratory motion estimates in numerical simulations. Cardiac and respiratory motions were then characterized in 27 patients who underwent LV mapping for treatment of ventricular tachycardia. Mean maximum amplitude of cardiac and respiratory motion was 10.2±2.7 mm (min = 5.5, max = 16.9) and 8.8±2.3 mm (min = 4.3, max = 14.8), respectively. 3D Cardiac and respiratory motions could be estimated from the recorded catheter location and the method does not rely on additional imaging modality such as X-ray fluoroscopy and can be used in conventional electrophysiology laboratory setting
    • …