3,081,311 research outputs found

    Sound-Ranging Apparatus

    Get PDF

    Concert: Period Instrument Performance Ensemble

    Get PDF

    Portable Chronograph

    Get PDF

    Evaluating Instrument Quality: Rasch Model – Analyses of Post Test of Curriculum 2013 Training

    Full text link
    The main purpose of this study was to evaluate the quality of post test utilized by LPMP Central Kalimantan Indonesia in curriculum 2013 training for X grade teachers. It uses Rasch analysis to explore the item fit, the reliability ( item and person), item difficulty, and the Wrigh map of post test. This study also applies Classical Test Teory (CTT) to determine item discrimination and distracters. Following a series of iterative Rasch analyses that adopted the “data should fit the model” approach, 30 items post test of curriculum 2013 training was analyzed using Acer Conquest 4 software, software based on Rasch measurement model. All items of post test of curriculum 2013 training are sufficient fit to the Rasch model. The difficulty levels (i.e. item measures) for the 30 items range from –1.746 logits to +1.861 logits. The item separation reliability is acceptable at 0.990 and person separation reliability is low at 0.485. The wright map indicates that the test is difficult for the teachers or the teachers have low ability in knowledge of curriculum 2013. The post test items cannot cover all the ranges of the teachers\u27 ability levels. Items discrimination of post test of curriculum 2013 training grouped into fair discrimination (item 2, 4, 5, 8, 11, 18) and poor discrimination (1, 3, 6, 7, 9, 10,12, 13, 14, 15, 16, 17, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30). Some distracters from item 1, 2, 6, 7, 8, 9, 11, 13, 16, 17, 18, 19, 20, 22, 24, 25, 27, 28, 29 and 30 are problematic. These distracters require further investigation or revision.   Key words: Rasch analysis, training, curriculum 2013, post tes

    HiWASE: instrument alignments

    Get PDF
    Alignment offsets between anemometers and motion-sensing instruments are a source of uncertainty for eddy correlation flux measurements made at sea. A previously described laboratory technique (Brooks, 2008) has been utilised to determine the pitch, roll and yaw offsets between flux instruments installed on the weathership Polarfront as part of the HiWASE project. Pitch and roll offsets were determined with an uncertainty of between 0.02° and 0.08°. Yaw offsets were determined with an uncertainty of between 0.5° and 1.2°

    The QUIET Instrument

    Get PDF
    The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales (~ 1 degree). Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4 m side-fed Dragonian telescope. The polarimeters which form the focal planes use a highly compact design based on High Electron Mobility Transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 uK sqrt(s)) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0.1. The 84-element W-band polarimeter array has a sensitivity of 87 uK sqrt(s) at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0.01. The two arrays together cover multipoles in the range l= 25-975. These are the largest HEMT-based arrays deployed to date. This article describes the design, calibration, performance of, and sources of systematic error for the instrument

    Tissue macerating instrument

    Get PDF
    A surgical tissue macerating and removal tool is described which has a rotating rod with a cutting member at one end and which disposed in a tube which is then contained in an extension of the tool handle. A frusto-conical member extends into the extension at the cutter member end of the rotating rod with its small end engaging the tube. The portion of the frusto-conical member outside of the extension forms a tissue engaging member and may be cut-off at an angle to the axis of the rod to form a tissue engaging edge. Apertures are provided in the extension adjacent the frusto-concial member so that treatment fluid supplied in the annular space between the tube and the extension may flow to the operative site. An aperture is provided in the frustoconical member between the extension and the tube so that fluid may also flow into the tube where it mixes with macerated tissue being directed through an aperture in the tube to a passageway which may have suction applied to help remove macerated material

    Aircraft instrument Patent

    Get PDF
    Aircraft indicator for pilot control of takeoff roll, climbout path and verticle flight path in poor visibility condition

    Thermogravimetric instrument

    Get PDF
    Thermogravimetric instrument to measure volatility under both isothermal and nonisothermal conditions and to study thermal decompositio
    corecore