52 research outputs found

    State of the art: iterative CT reconstruction techniques

    Get PDF
    Owing to recent advances in computing power, iterative reconstruction (IR) algorithms have become a clinically viable option in computed tomographic (CT) imaging. Substantial evidence is accumulating about the advantages of IR algorithms over established analytical methods, such as filtered back projection. IR improves image quality through cyclic image processing. Although all available solutions share the common mechanism of artifact reduction and/or potential for radiation dose savings, chiefly due to image noise suppression, the magnitude of these effects depends on the specific IR algorithm. In the first section of this contribution, the technical bases of IR are briefly reviewed and the currently available algorithms released by the major CT manufacturers are described. In the second part, the current status of their clinical implementation is surveyed. Regardless of the applied IR algorithm, the available evidence attests to the substantial potential of IR algorithms for overcoming traditional limitations in CT imaging

    Real-time turbulence profiling with a pair of laser guide star Shack–Hartmann wavefront sensors for wide-field adaptive optics systems on large to extremely large telescopes

    Get PDF
    Real-time turbulence profiling is necessary to tune tomographic wavefront reconstruction algorithms for wide-field adaptive optics (AO) systems on large to extremely large telescopes, and to perform a variety of image post-processing tasks involving point-spread function reconstruction. This paper describes a computationally efficient and accurate numerical technique inspired by the slope detection and ranging (SLODAR) method to perform this task in real time from properly selected Shack–Hartmann wavefront sensor measurements accumulated over a few hundred frames from a pair of laser guide stars, thus eliminating the need for an additional instrument. The algorithm is introduced, followed by a theoretical influence function analysis illustrating its impulse response to high-resolution turbulence profiles. Finally, its performance is assessed in the context of the Thirty Meter Telescope multi-conjugate adaptive optics system via end-to-end wave optics Monte Carlo simulations

    Inter-Pixel Crosstalk in Teledyne Imaging Sensors (TIS) H4RG-10 Detectors

    Full text link
    CMOS-hybrid arrays have recently surfaced as competitive optical detectors for use in ground- and space-based astronomy. One source of error in these detectors that does not appear in more traditional CCD arrays is the inter-pixel capacitance component of crosstalk. In this paper we use a single pixel reset method to model inter-pixel capacitance (IPC). We combine this IPC model with a model for charge diffusion to estimate the total crosstalk on H4RG arrays. Finally, we compare our model results to Fe55 data obtained using an astrometric camera built to test the H4RG-B0 generation detectors.Comment: Accepted to Applied Optics 03-26-1

    Estimation of the mixing kernel and the disturbance covariance in IDE-based spatiotemporal systems

    Get PDF
    The integro-difference equation (IDE) is an increasingly popular mathematical model of spatiotemporal processes, such as brain dynamics, weather systems, and disease spread. We present an efficient approach for system identification based on correlation techniques for linear temporal systems that extended to spatiotemporal IDE-based models. The method is derived from the average (over time) spatial correlations of observations to calculate closed-form estimates of the spatial mixing kernel and the disturbance covariance function. Synthetic data are used to demonstrate the performance of the estimation algorithm

    Building real-time embedded applications on QduinoMC: a web-connected 3D printer case study

    Full text link
    Single Board Computers (SBCs) are now emerging with multiple cores, ADCs, GPIOs, PWM channels, integrated graphics, and several serial bus interfaces. The low power consumption, small form factor and I/O interface capabilities of SBCs with sensors and actuators makes them ideal in embedded and real-time applications. However, most SBCs run non-realtime operating systems based on Linux and Windows, and do not provide a user-friendly API for application development. This paper presents QduinoMC, a multicore extension to the popular Arduino programming environment, which runs on the Quest real-time operating system. QduinoMC is an extension of our earlier single-core, real-time, multithreaded Qduino API. We show the utility of QduinoMC by applying it to a specific application: a web-connected 3D printer. This differs from existing 3D printers, which run relatively simple firmware and lack operating system support to spool multiple jobs, or interoperate with other devices (e.g., in a print farm). We show how QduinoMC empowers devices with the capabilities to run new services without impacting their timing guarantees. While it is possible to modify existing operating systems to provide suitable timing guarantees, the effort to do so is cumbersome and does not provide the ease of programming afforded by QduinoMC.http://www.cs.bu.edu/fac/richwest/papers/rtas_2017.pdfAccepted manuscrip

    Method and phantom to study combined effects of in-plane (x,y) and z-axis resolution for 3D CT imaging.

    Get PDF
    Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) influence the visual-ization and detection of objects within the scanned volume. This study investigates ways to consider both the in-plane resolution and the z-axis resolution in a single phantom wherein analytic or visualized analysis can yield information on these combined effects. A new phantom called the Wave Phantom is developed that can be used to sample the 3D resolution properties of a CT image, including in-plane (x,y) and z-axis information. The key development in this Wave Phantom is the incorporation of a z-axis aspect of a more traditional step (bar) resolution gauge phantom. The phantom can be examined visually wherein a cutoff level may be seen; and/or the analytic analysis of the various characteristics of the waveform profile by including amplitude, frequency, and slope (rate of climb) of the peaks, can be extracted from the Wave Pattern using mathematical analysis such as the Fourier transform. The combined effect of changes in in-plane resolution and z-axis (thickness), are shown, as well as the effect of changes in either in-plane resolu-tion, or z-axis thickness. Examples of visual images of the Wave pattern as well as the analytic characteristics of the various harmonics of a periodic Wave pattern resulting from changes in resolution filter and/or slice thickness, and position in the field of view are shown. The Wave Phantom offers a promising way to investigate 3D resolution results from combined effect of in-plane (x-y) and z-axis resolution as contrasted to the use of simple 2D resolution gauges that need to be used with separate measures of z-axis dependency, such as angled ramps. It offers both a visual pattern as well as a pattern amenable to analytic analysis using Fourier Transform methods, and is believed to offer an image quality test closer to the diagnostic task where the 2D image has the hidden third (z) axis effects

    Radiation dose reduction in pediatric great vessel stent computed tomography using iterative reconstruction: A phantom study

    Get PDF
    Background To study dose reduction using iterative reconstruction (IR) for pediatric great vessel stent computed tomography (CT). Methods Five different great vessel stents were separately placed in a gel-containing plastic holder within an anthropomorphic chest phantom. The stent lumen was filled with diluted contrast gel. CT acquisitions were performed at routine dose, 52% and 81% reduced dose and reconstructed with filtered back projection (FBP) and IR. Objective image quality in terms of noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as subjective image quality were evaluated. Results Noise, SNR and CNR were improved with IR at routine and 52% reduced dose, compared to FBP at routine dose. The lowest dose level resulted in decreased objective image quality with both FBP and IR. Subjective image quality was excellent at all dose levels. Conclusion IR resulted in improved objective image quality at routine dose and 52% reduced dose, while objective image quality deteriorated at 81% reduced dose. Subjective image quality was not affected by dose reduction
    corecore