64 research outputs found

    Diagnostic Confidence of Run-Off CT-Angiography as the Primary Diagnostic Imaging Modality in Patients Presenting with Acute or Chronic Peripheral Arterial Disease

    Get PDF
    Objectives To investigate the reliability of CT-angiography of the lower extremities (run-off CTA) to derive a treatment decision in patients with acute and chronic peripheral artery disease (PAD). Materials and Methods 314 patients referred for run-off CTA were includ-ed in this retrospective study. First, diagnostic confidence of run-off CTA to derive a treat-ment decision was assessed in an interdisciplinary vascular conference using a 2 point scale (sufficient or not sufficient diagnostic confidence) and compared with the image quality eval-uated by two readers in consensus in four different levels (abdominopelvic, thigh, calf, foot arteries). Second, reliability of treatment decision was verified in all patients undergoing re-vascularization therapy. Results Diagnostic confidence of run-off CTA to derive a treatment deci-sion was sufficient in all patients with acute and in 97% of patients (215/221) with chronic PAD, whereas the rate of run-off CTA with non-diagnostic image quality was considerably higher in the calf and foot level (acute vs. chronic; calf: 28% vs.17%; foot: 52% vs. 20%). Reliability of treatment decision was superior for patients with chronic (123/133 = 92%) than for patients with acute PAD (64/78 = 82%, P = 0.02). Conclusion Run-off CTA is a reliable imaging modality for primary diag-nostic work-up of patients with acute and chronic PAD

    Lung tumour growth kinetics in SPC-c-Raf-1-BB transgenic mice assessed by longitudinal in-vivo micro-CT quantification

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>SPC-c-Raf-1-BxB transgenic mice develop genetically induced disseminated lung adenocarcinoma allowing examination of carcinogenesis and evaluation of novel treatment strategies. We report on assessment of lung tumour growth kinetics using a semiautomated region growing segmentation algorithm.</p> <p>Methods</p> <p>156 non contrast-enhanced respiratory gated micro-CT of the lungs were obtained in 12 SPC-raf transgenic (n = 9) and normal (n = 3) mice at different time points. Region-growing segmentation of the aerated lung areas was obtained as an inverse surrogate for tumour burden. Time course of segmentation volumes was assessed to demonstrate the potential of the method for follow-up studies.</p> <p>Results</p> <p>Micro-CT allowed assessment of tumour growth kinetics and semiautomated region growing enabled quantitative analysis. Significant changes of the segmented lung volumes over time could be shown (<it>p </it>= 0.009). Significant group differences could be detected between transgenic and normal animals for time points 8 to 13 months (<it>p </it>= 0.043), when marked tumour progression occurred.</p> <p>Conclusion</p> <p>The presented region-growing segmentation algorithm allows in-vivo quantification of multifocal lung adenocarcinoma in SPC-raf transgenic mice. This enables the assessment of tumour load and progress for the study of carcinogenesis and the evaluation of novel treatment strategies.</p

    Röntgen-Apps: Einsatz in der Grauzone

    No full text
    Albrecht U-V, von Falck C, Pramann O. Röntgen-Apps: Einsatz in der Grauzone. Deutsches Ärzteblatt. 2013;110(14):A-652/B-580/C-580

    Evaluation of transient respiratory motion artifact at gadoxetate disodium-enhanced MRI-Influence of different contrast agent application protocols.

    No full text
    PURPOSE:To evaluate transient severe respiratory motion artifacts (TSM) at gadoxetate disodium-enhanced MRI dependent on the mode of contrast agent application. METHODS:200 patients (71f, 129m; mean 51y) were included in this retrospective IRB-approved study. Contrast application protocols (n = 4) differed with regards to injection rate (2ml or 1ml/sec), dose (weight-based or fixed 10ml) and supplemental oxygen administration (yes/no). SNR measurements were performed in the aorta and portal vein. Qualitatively, three readers assessed arterial phase image quality and TSM independently (4- and 5-point scale, respectively). Quantitative and qualitative results were compared (Kruskal-Wallis test, Dunn's multiple comparison test). The influence of different contrast agent application parameters on the occurrence of respiratory motion artifacts was assessed (univariate analysis). Interrater agreement and reliability were calculated (intraclass correlation coefficient, ICC)). RESULTS:Use of a lower contrast injection rate resulted in significantly higher arterial SNR in the aorta and portal vein (p<0.05). TSM was observed in 12% of examinations. Neither injection rate, contrast dose, nor oxygen had a significant influence. Interrater agreement and reliability for evaluation of image quality and respiratory motion were substantial/ almost perfect (ICC = 0.640-0.915). CONCLUSIONS:Technical factors regarding the specific mode of contrast application do not seem to significantly reduce the incidence of severe transient respiratory motion artifacts

    3D-MRCP for evaluation of intra- and extrahepatic bile ducts: comparison of different acquisition and reconstruction planes

    Get PDF
    BACKGROUND: Magnetic resonance cholangiopancreatography (MRCP) is an established technique for the evaluation of intra- and extrahepatic bile ducts in patients with known or suspected hepatobiliary disease. However, the ideal acquisition and reconstruction plane for optimal bile duct evaluation with 3D technique has not been evaluated. The purpose of our study was to compare different acquisition and reconstruction planes of 3D-MRCP for bile duct assessment. METHODS: 34 patients (17f/17 m, mean age 41y) referred for MRCP were included in this prospective IRB-approved study. Respiratory-triggered 3D-T2w-MRCP sequences were acquired in coronal and axial plane. Coronal and axial MIP were reconstructed based on each dataset (resulting in two coronal and two axial MIP, respectively). Three readers in two sessions independently assessed the MIP, regarding visualization of bile ducts and image quality. Results were compared (Wilcoxon test). Intra- and interobserver variability were calculated (kappa-statistic). RESULTS: In case of coronal data acquisition, visualization of bile duct segments was significantly better on coronal reconstructed MIP images as compared to axial reconstructed MIP (p < 0.05). Regarding visualization, coronal MIP of the coronal acquisition were equal to coronal MIP of the axial acquisition (p > 0.05). Image quality of coronal and axial datasets did not differ significantly. Intra- and interobserver agreement regarding bile duct visualization were moderate to excellent (κ-range 0.55-1.00 and 0.42-0.85, respectively). CONCLUSIONS: The results of our study suggest that for visualization and evaluation of intra- and extrahepatic bile duct segments reconstructed images in coronal orientation are preferable. The orientation of the primary dataset (coronal or axial) is negligible

    CT based PSI blocks for osteotomies around the knee provide accurate results when intraoperative imaging is used

    No full text
    Purpose!#!Correction osteotomies around the knee are common methods for the treatment of varus or valgus malalignment of the lower extremity. In recent years, patient specific instrumentation (PSI) guides were introduced in order to enhance the accuracy of these procedures. The purpose of this study was to determine the accuracy of CT based PSI guides for correction osteotomies around the knee of low volume osteotomy surgeons and to evaluate if CT based PSI blocks deliver a high degree of accuracy without using intraoperative fluoroscopy.!##!Methods!#!Two study arms with CT based PSI cutting blocks for osteotomies around the knee were conducted. Part one: A retrospective analysis of 19 osteotomies was made in order to evaluate the accuracy in the hands of a low volume surgeon on long-leg radiographs. Part two: A cadaveric study with 8 knees was performed for the purpose of analyzing the accuracy without using intraoperative fluoroscopy on pre- and postoperative CT scans. Hip-Knee-Ankle angle (HKA), lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) were analyzed. The mean absolute delta (∂) between the planned and postoperative parameters were calculated. The accuracy of both study arms were compared.!##!Results!#!Part one: The mean MPTA ∂, LDFA ∂ and HKA ∂ was 0.9°, 1.9° and 1.5°, respectively. Part two: The mean MPTA ∂ and LDFA ∂ was 3.5° and 2.2°, respectively. The mean ∂ of MPTA is significantly different between clinical patients with fluoroscopic control and cadaveric specimens without fluoroscopic control (P &amp;lt; 0.001). All surgeries were performed without complications such as a hinge fracture.!##!Conclusion!#!The clinical use of PSI guides for osteotomies around the knee in the hands of low volume surgeons is a safe procedure. The PSI guides deliver a reliable accuracy under fluoroscopic control whereas their non-use of intraoperative fluoroscopy leads to a lack of accuracy. The use of fluoroscopic control during PSI guided correction osteotomies is highly recommended.!##!Level of evidence!#!IV - Retrospective and experimental Study

    First Experience in the Control of the Venous Side of the Brain AVM

    No full text
    Background and purpose: Brain arteriovenous malformations (AVM) are increasingly curable with endovascular embolization. This study examines the preliminary experience with a novel double-sided hybrid approach in the treatment of cerebral arteriovenous malformations (AVM) versus a purely single-sided intra-arterial approach. Materials and methods: The single-center study cohort included 18 patients with brain AVMs (Spetzler–Martin Grade 2 or 3) having stand-alone endovascular treatment with either the arterial-side-only pressure cooker technique (aPCT) (group 1; n = 9) or a double-sided hybrid intra-arterial and transvenous approach (HIPRENE) (group 2; n = 9). Results: Patients belonging to group 2 had lower rates of intra-procedural hemorrhaging (66.7% vs. 33.3%, p = 0.169) and needed fewer treatment sessions to achieve nidus occlusion (1.7 vs. 1.2, p = 0.136). The HIPRENE treatment regime led to higher nidus occlusion rates after the initial treatment compared to aPCT (77.7% vs. 44.4%, p = 0.167). Group 2 patients had a lower rate of neuromonitoring events (22.2% vs. 44.4%, p = 0.310) and fewer accounts of blood flow obstruction in post-operative MRIs (33.3% vs. 55.6%, p = 0.319). Conclusion: A double-sided hybrid intra-arterial and transvenous approach might have benefits for curative endovascular brain AVM treatment in patients with Spetzler–Martin Grade 2 or 3. In our small study cohort, the HIPRENE treatment regime had higher nidus occlusion rates after the first treatment, which reduces the number of treatment sessions and lowers intra- and post-operative complication rates. Further randomized controlled studies are awaited to corroborate our preliminary outcomes

    A Comparative Evaluation of Standard and Balloon-Assisted Coiling of Intracranial Aneurysms Based on Neurophysiological Monitoring

    No full text
    Background and purpose: Intracranial aneurysms are commonly treated with balloon-assisted endovascular coiling because the balloon allows for the control und modulation of wide-necked aneurysms and the coil basket. However, this approach might be associated with a higher complication rate. This retrospective study compared the multimodal results between balloon-assisted coiling of aneurysms (group 1) and coiling without balloon assistance (group 2). Materials and Methods: We included 67 patients with unruptured intracranial aneurysms in this retrospective analysis; acutely ruptured aneurysms were excluded from the analysis. We divided these patients into two groups and evaluated them for symptomatic thromboembolic complications in the course of intracranial aneurysm treatment. All patients had an intrainterventional neurophysiological monitoring (IINM) and a pre- and postinterventional NIH Stoke Scale (NIHSS) survey and MR imaging. Multiple logistic regression was used to assess whether balloon-assisted coiling increased the rate of thromboembolic complications. Periprocedural aneurysm hemorrhage did not occur in any of the cases. Results: We detected no statistically significant difference in rates of neurophysiological disturbances (19.5% (group 1) versus 34.6% (group 2); p = 0.249). There was no association with age, gender, or aneurysm location. The occurrence of new diffusion-weighted defects was not statistically significantly different (19.5% (group 1) versus 35.0% (group 2); p = 0.166). The difference in NIHSS before and after the intervention showed also no statistical significance in both groups (p = 0.426). Conclusion: The use of balloon-assisted coiling did not increase the rate of neurological disturbances during endovascular coiling. MR imaging and NIHSS survey also showed no increased risk of embolization from balloon-assisted aneurysm coiling. IINM is a central aspect of care during endovascular coiling as it can substantially decrease morbidity
    corecore