44 research outputs found
Six-beam homodyne laser Doppler vibrometry based on silicon photonics technology
This paper describes an integrated six-beam homodyne laser Doppler vibrometry (LDV) system based on a silicon-on-insulator (SOI) full platform technology, with on-chip photo-diodes and phase modulators. Electronics and optics are also implemented around the integrated photonic circuit (PIC) to enable a simultaneous six-beam measurement. Measurement of a propagating guided elastic wave in an aluminum plate (speed ≈≈ 909 m/s @ 61.5 kHz) is demonstrated
Recommended from our members
Device-detected atrial fibrillation and risk for stroke: an analysis of >10 000 patients from the SOS AF project (Stroke preventiOn Strategies based on Atrial Fibrillation information from implanted devices)
Objective: The aim of this study was to assess the association between maximum daily atrial fibrillation (AF) burden and risk of ischaemic stroke. Background: Cardiac implanted electronic devices (CIEDs) enhance detection of AF, providing a comprehensive measure of AF burden. Design, setting, and patients A pooled analysis of individual patient data from five prospective studies was performed. Patients without permanent AF, previously implanted with CIEDs, were included if they had at least 3 months of follow-up. A total of 10 016 patients (median age 70 years) met these criteria. The risk of ischaemic stroke associated with pre-specified cut-off points of AF burden (5 min, 1, 6, 12, and 23 h, respectively) was assessed. Results: During a median follow-up of 24 months, 43% of 10 016 patients experienced at least 1 day with at least 5 min of AF burden and for them the median time to the maximum AF burden was 6 months (inter-quartile range: 1.3–14). A Cox regression analysis adjusted for the CHADS2 score and anticoagulants at baseline demonstrated that AF burden was an independent predictor of ischaemic stroke. Among the thresholds of AF burden that we evaluated, 1 h was associated with the highest hazard ratio (HR) for ischaemic stroke, i.e. 2.11 (95% CI: 1.22–3.64, P = 0.008). Conclusions: Device-detected AF burden is associated with an increased risk of ischaemic stroke in a relatively unselected population of CIEDs patients. This finding may add to the basis for timely and clinically appropriate decision-making on anticoagulation treatment
Speckle mitigation in laser Doppler vibrometry based on a compact silicon photonics chip
A compact six-beam homodyne laser Doppler vibrometry (LDV) system is realized based on a silicon-on-insulator (SOI) photonic integrated circuit. We demonstrate a speckle mitigation method by averaging signals from the six channels
Time of onset of atrial fibrillation and atrial fibrillation progression data from the RACE V study
Aims: Atrial fibrillation (AF) progression is associated with adverse outcome, but the role of the circadian or diurnal pattern of AF onset remains unclear. We aim to assess the association between the time of onset of AF episodes with the clinical phenotype and AF progression in patients with self-terminating AF.Methods and results: The Reappraisal of AF: Interaction Between Hypercoagulability, Electrical Remodelling, and Vascular Destabilization in the and results Progression of AF study included patients with self-terminating AF who underwent extensive phenotyping at baseline and continuous rhythm monitoring with an implantable loop recorder (ILR). In this subanalysis, ILR data were used to assess the development of AF progression and the diurnal pattern of AF onset: predominant (>80%) nocturnal AF, predominant daytime AF, or mixed AF without a predominant diurnal AF pattern. The median follow-up was 2.2 (1.6–2.8) years. The median age was 66 (59–71) years, and 117 (42%) were women. Predominant nocturnal (n = 40) and daytime (n = 43) AF onset patients had less comorbidities compared to that of mixed (n = 195) AF patients (median 2 vs. 2 vs. 3, respectively, P = 0.012). Diabetes was more common in the mixed group (12% vs. 5% vs. 0%, respectively, P = 0.031), whilst obesity was more frequent in the nocturnal group (38% vs. 12% vs. 27%, respectively, P = 0.028). Progression rates in the nocturnal vs. daytime vs. mixed groups were 5% vs. 5% vs. 24%, respectively (P = 0.013 nocturnal vs. mixed and P = 0.008 daytime vs. mixed group, respectively).Conclusion: In self-terminating AF, patients with either predominant nocturnal or daytime onset of AF episodes had less associated comorbidities and less AF progression compared to that of patients with mixed onset of AF.</p
Non-invasive cardiovascular disease assessment with miniaturized multi-beam laser Doppler vibrometry
A miniaturized 2×6-beam laser Doppler vibrometry sensor for non-invasive detection of cardiovascular disease is demonstrated. The pulse wave velocity is retrieved from preliminary experiments both on phantoms and on human subjects
Time of onset of atrial fibrillation and atrial fibrillation progression data from the RACE V study
Aims: Atrial fibrillation (AF) progression is associated with adverse outcome, but the role of the circadian or diurnal pattern of AF onset remains unclear. We aim to assess the association between the time of onset of AF episodes with the clinical phenotype and AF progression in patients with self-terminating AF.Methods and results: The Reappraisal of AF: Interaction Between Hypercoagulability, Electrical Remodelling, and Vascular Destabilization in the and results Progression of AF study included patients with self-terminating AF who underwent extensive phenotyping at baseline and continuous rhythm monitoring with an implantable loop recorder (ILR). In this subanalysis, ILR data were used to assess the development of AF progression and the diurnal pattern of AF onset: predominant (>80%) nocturnal AF, predominant daytime AF, or mixed AF without a predominant diurnal AF pattern. The median follow-up was 2.2 (1.6–2.8) years. The median age was 66 (59–71) years, and 117 (42%) were women. Predominant nocturnal (n = 40) and daytime (n = 43) AF onset patients had less comorbidities compared to that of mixed (n = 195) AF patients (median 2 vs. 2 vs. 3, respectively, P = 0.012). Diabetes was more common in the mixed group (12% vs. 5% vs. 0%, respectively, P = 0.031), whilst obesity was more frequent in the nocturnal group (38% vs. 12% vs. 27%, respectively, P = 0.028). Progression rates in the nocturnal vs. daytime vs. mixed groups were 5% vs. 5% vs. 24%, respectively (P = 0.013 nocturnal vs. mixed and P = 0.008 daytime vs. mixed group, respectively).Conclusion: In self-terminating AF, patients with either predominant nocturnal or daytime onset of AF episodes had less associated comorbidities and less AF progression compared to that of patients with mixed onset of AF.</p
Brady- and tachyarrhythmias detected by continuous rhythm monitoring in paroxysmal atrial fibrillation
Objective: Atrial fibrillation (AF) is associated with adverse events including conduction disturbances, ventricular arrhythmias and sudden death. The aim of this study was to examine brady- and tachyarrhythmias using continuous rhythm monitoring in patients with paroxysmal self-terminating AF (PAF). Methods: In this multicentre observational substudy to the Reappraisal of Atrial Fibrillation: interaction between hyperCoagulability, Electrical remodelling and Vascular destabilisation in the progression of AF (RACE V), we included 392 patients with PAF and at least 2 years of continuous rhythm monitoring. All patients received an implantable loop recorder, and all detected episodes of tachycardia ≥182 beats per minute (BPM), bradycardia ≤30 BPM or pauses ≥5 s were adjudicated by three physicians. Results: Over 1272 patient-years of continuous rhythm monitoring, we adjudicated 1940 episodes in 175 patients (45%): 106 (27%) patients experienced rapid AF or atrial flutter (AFL), pauses ≥5 s or bradycardias ≤30 BPM occurred in 47 (12%) patients and in 22 (6%) patients, we observed both episode types. No sustained ventricular tachycardias occurred. In the multivariable analysis, age >70 years (HR 2.3, 95% CI 1.4 to 3.9), longer PR interval (HR 1.9, 1.1-3.1), CHA2DS2-VASc score ≥2 (HR 2.2, 1.1-4.5) and treatment with verapamil or diltiazem (HR 0.4, 0.2-1.0) were significantly associated with bradyarrhythmia episodes. Age >70 years was associated with lower rates of tachyarrhythmias. Conclusions: In a cohort exclusive to patients with PAF, almost half experienced severe bradyarrhythmias or AF/AFL with rapid ventricular rates. Our data highlight a higher than anticipated bradyarrhythmia risk in PAF. Trial registration number: NCT02726698.</p
Brady- and tachyarrhythmias detected by continuous rhythm monitoring in paroxysmal atrial fibrillation
Objective: Atrial fibrillation (AF) is associated with adverse events including conduction disturbances, ventricular arrhythmias and sudden death. The aim of this study was to examine brady- and tachyarrhythmias using continuous rhythm monitoring in patients with paroxysmal self-terminating AF (PAF). Methods: In this multicentre observational substudy to the Reappraisal of Atrial Fibrillation: interaction between hyperCoagulability, Electrical remodelling and Vascular destabilisation in the progression of AF (RACE V), we included 392 patients with PAF and at least 2 years of continuous rhythm monitoring. All patients received an implantable loop recorder, and all detected episodes of tachycardia ≥182 beats per minute (BPM), bradycardia ≤30 BPM or pauses ≥5 s were adjudicated by three physicians. Results: Over 1272 patient-years of continuous rhythm monitoring, we adjudicated 1940 episodes in 175 patients (45%): 106 (27%) patients experienced rapid AF or atrial flutter (AFL), pauses ≥5 s or bradycardias ≤30 BPM occurred in 47 (12%) patients and in 22 (6%) patients, we observed both episode types. No sustained ventricular tachycardias occurred. In the multivariable analysis, age >70 years (HR 2.3, 95% CI 1.4 to 3.9), longer PR interval (HR 1.9, 1.1-3.1), CHA2DS2-VASc score ≥2 (HR 2.2, 1.1-4.5) and treatment with verapamil or diltiazem (HR 0.4, 0.2-1.0) were significantly associated with bradyarrhythmia episodes. Age >70 years was associated with lower rates of tachyarrhythmias. Conclusions: In a cohort exclusive to patients with PAF, almost half experienced severe bradyarrhythmias or AF/AFL with rapid ventricular rates. Our data highlight a higher than anticipated bradyarrhythmia risk in PAF. Trial registration number: NCT02726698.</p
Brady- and tachyarrhythmias detected by continuous rhythm monitoring in paroxysmal atrial fibrillation
Objective: Atrial fibrillation (AF) is associated with adverse events including conduction disturbances, ventricular arrhythmias and sudden death. The aim of this study was to examine brady- and tachyarrhythmias using continuous rhythm monitoring in patients with paroxysmal self-terminating AF (PAF). Methods: In this multicentre observational substudy to the Reappraisal of Atrial Fibrillation: interaction between hyperCoagulability, Electrical remodelling and Vascular destabilisation in the progression of AF (RACE V), we included 392 patients with PAF and at least 2 years of continuous rhythm monitoring. All patients received an implantable loop recorder, and all detected episodes of tachycardia ≥182 beats per minute (BPM), bradycardia ≤30 BPM or pauses ≥5 s were adjudicated by three physicians. Results: Over 1272 patient-years of continuous rhythm monitoring, we adjudicated 1940 episodes in 175 patients (45%): 106 (27%) patients experienced rapid AF or atrial flutter (AFL), pauses ≥5 s or bradycardias ≤30 BPM occurred in 47 (12%) patients and in 22 (6%) patients, we observed both episode types. No sustained ventricular tachycardias occurred. In the multivariable analysis, age >70 years (HR 2.3, 95% CI 1.4 to 3.9), longer PR interval (HR 1.9, 1.1-3.1), CHA2DS2-VASc score ≥2 (HR 2.2, 1.1-4.5) and treatment with verapamil or diltiazem (HR 0.4, 0.2-1.0) were significantly associated with bradyarrhythmia episodes. Age >70 years was associated with lower rates of tachyarrhythmias. Conclusions: In a cohort exclusive to patients with PAF, almost half experienced severe bradyarrhythmias or AF/AFL with rapid ventricular rates. Our data highlight a higher than anticipated bradyarrhythmia risk in PAF. Trial registration number: NCT02726698.</p