11 research outputs found

    A fixed-lag Kalman smoother to filter power line interference in electrocardiogram recordings

    Get PDF
    \u3cp\u3eObjective: Filtering power line interference (PLI) from electrocardiogram (ECG) recordings can lead to significant distortions of the ECG and mask clinically relevant features in ECG waveform morphology. The objective of this study is to filter PLI from ECG recordings with minimal distortion of the ECG waveform. Methods: In this paper, we propose a fixed-lag Kalman smoother with adaptive noise estimation. The performance of this Kalman smoother in filtering PLI is compared to that of a fixed-bandwidth notch filter and several adaptive PLI filters that have been proposed in the literature. To evaluate the performance, we corrupted clean neonatal ECG recordings with various simulated PLI. Furthermore, examples are shown of filtering real PLI from an adult and a fetal ECG recording. Results: The fixed-lag Kalman smoother outperforms other PLI filters in terms of step response settling time (improvements that range from 0.1 to 1 s) and signal-to-noise ratio (improvements that range from 17 to 23 dB). Our fixed-lag Kalman smoother can be used for semi real-time applications with a limited delay of 0.4 s. Conclusion and Significance: The fixed-lag Kalman smoother presented in this study outperforms other methods for filtering PLI and leads to minimal distortion of the ECG waveform.\u3c/p\u3

    Hierarchical probabilistic framework for fetal R-peak detection, using ECG waveform and heart rate information

    No full text
    \u3cp\u3eThe abdominal fetal electrocardiogram (fECG) can provide valuable information about fetal well-being. However, fetal R-peak detection in abdominal fECG recordings is challenging due to the low signal-to-noise ratio (SNR) and the nonstationary nature of the fECG waveform in the abdominal recordings. In this paper, we propose a multichannel hierarchical probabilistic framework for fetal R-peak detection that combines predictive models of the ECG waveform and the heart rate. The performance of our method was evaluated on set-A of the 2013 Physionet/Computing in Cardiology Challenge and compared to the performance of several methods that have been proposed in the literature. The hierarchical probabilistic framework presented in this study outperforms other methods for fetal R-peak detection with a mean overall detection accuracy for set-A of 99.6%. Even for recordings with low SNR our method enables reliable fetal R-peak detection (Ac 99.4%).\u3c/p\u3

    The fetal electrocardiogram to detect the effects of betamethasone on fetal heart rate variability.

    No full text
    \u3cp\u3eBackground: Betamethasone is widely used to enhance fetal lung maturation in case of threatened preterm birth. Antenatal corticosteroids are known to reduce fetal heart rate variability (fHRV) in the days following administration. Since decreased fHRV is a marker for fetal distress, this transient decrease of fHRV can cause unnecessary medical intervention. Aim: To describe the effect of betamethasone on fHRV, by applying spectral analysis on non-invasive fetal electrocardiogram (fECG) recordings. Study design: Secondary analysis of a prospective cohort study. Subjects: Women with a singleton pregnancy, at risk for preterm delivery and receiving betamethasone, admitted to the obstetric high care unit in the period from March 2013 until July 2016. Outcome measures: The primary outcome measure was fHRV in both time- and frequency-domain. Secondary outcome measures included basal fetal heart rate (fHR) and fHR variance. FHRV parameters were then calculated separately for the quiet and active state. Results: Following 68 inclusions, 22 patients remained with complete series of measurements and sufficient data quality. FHRV parameters and fHR showed a decrease on day 2 compared to day 1, significant for short-term variability and high-frequency power. Similar results were found when analyzing for separate behavioral states. The number of segments in quiet state increased during days 1 and 2. Normalized values showed no difference for all behavioral states. Conclusion: FHRV decreases on day 2 after betamethasone administration, while periods of fetal quiescence increase. No changes were found in the normalized values, indicating that the influence of autonomic modulation is minor. Clinical trial registration number NL43294.015.13\u3c/p\u3

    Head orientation and electrode placement potentially influence fetal scalp ECG waveform

    Get PDF
    \u3cp\u3eBackground Fetal monitoring based on electrocardiographic (ECG) morphology is obtained from a single unipolar fetal scalp electrode. Ideally, it should be obtained from multiple leads, as ECG waveform depends on alignment between electrode and electrical heart axis. This alignment is unknown in fetuses. Besides, fetuses are surrounded by conductive media, which may influence ECG waveform. We explored the influence of electrode position and head orientation on ECG waveforms of unipolar and bipolar scalp ECGs recorded in air and in conductive medium. Methods We recorded ECGs in one adult subject at five different scalp positions in five different head orientations both in dry and immersed conditions. The ratio between T-amplitude and QRS-amplitude (T/QRS ratio) of unipolar and bipolar scalp ECGs was determined and compared between all conditions. Results In the dry condition, we observed in the unipolar leads little to no difference between different electrode positions (maximal T/QRS difference 0.00–0.01) and minor differences between head orientations (0.02–0.03), whereas bipolar leads showed no recognizable ECG signal at all. During the immersed condition, we found variation in the unipolar leads, both between electrode positions (maximal T/QRS difference 0.02–0.05) and between head orientations (0.03–0.06). Bipolar leads showed different ECG signals in contrasting head orientations. Conclusions Both unipolar and bipolar scalp lead-derived ECG waveforms are influenced by electrode position and head orientation when the subject is submerged in a conductive medium. Fetal monitoring based on single scalp lead ECG waveform might be suboptimal, as it lacks correction for fetal head orientation and electrode position.\u3c/p\u3

    Detection rate of fetal distress using contraction-dependent fetal heart rate variability analysis

    Get PDF
    \u3cp\u3eObjective: Monitoring of the fetal condition during labor is currently performed by cardiotocograpy (CTG). Despite the use of CTG in clinical practice, CTG interpretation suffers from a high inter- and intra-observer variability and a low specificity. In addition to CTG, analysis of fetal heart rate variability (HRV) has been shown to provide information on fetal distress. However, fetal HRV can be strongly influenced by uterine contractions, particularly during the second stage of labor. Therefore, the aim of this study is to examine if distinguishing contractions from rest periods can improve the detection rate of HRV features for fetal distress during the second stage of labor. Approach: We used a dataset of 100 recordings, containing 20 cases of fetuses with adverse outcome. The most informative HRV features were selected by a genetic algorithm and classification performance was evaluated using support vector machines. Main results: Classification performance of fetal heart rate segments closest to birth improved from a geometric mean of 70% to 79%. If the classifier was used to indicate fetal distress over time, the geometric mean at 15 minutes before birth improved from 60% to 72%. Significance: Our results show that combining contraction-dependent HRV features with HRV features calculated over the entire fetal heart rate signal improves the detection rate of fetal distress.\u3c/p\u3

    Using uterine activity to improve fetal heart rate variability analysis for detection of asphyxia during labor

    No full text
    During labor, uterine contractions can cause temporary oxygen deficiency for the fetus. In case of severe and prolonged oxygen deficiency this can lead to asphyxia. The currently used technique for detection of asphyxia, cardiotocography (CTG), suffers from a low specificity. Recent studies suggest that analysis of fetal heart rate variability (HRV) in addition to CTG can provide information on fetal distress. However, interpretation of fetal HRV during labor is difficult due to the influence of uterine contractions on fetal HRV. The aim of this study is therefore to investigate whether HRV features differ during contraction and rest periods, and whether these differences can improve the detection of asphyxia. To this end, a case-control study was performed, using 14 cases with asphyxia that were matched with 14 healthy fetuses. We did not find significant differences for individual HRV features when calculated over the fetal heart rate without separating contractions and rest periods (p  >  0.30 for all HRV features). Separating contractions from rest periods did result in a significant difference. In particular the ratio between HRV features calculated during and outside contractions can improve discrimination between fetuses with and without asphyxia (p  <  0.04 for three out of four ratio HRV features that were studied in this paper)

    The influence of betamethasone on fetal heart rate variability, obtained by non-invasive fetal electrocardiogram recordings

    No full text
    \u3cp\u3eBackground: Betamethasone is widely used to enhance fetal lung maturation in case of threatened preterm labour. Fetal heart rate variability is one of the most important parameters to assess in fetal monitoring, since it is a reliable indicator for fetal distress. Aim: To describe the effect of betamethasone on fetal heart rate variability, by applying spectral analysis on non-invasive fetal electrocardiogram recordings. Study design: Prospective cohort study. Subjects: Patients that require betamethasone, with a gestational age from 24 weeks onwards. Outcome measures: Fetal heart rate variability parameters on day 1, 2, and 3 after betamethasone administration are compared to a reference measurement. Results: Following 68 inclusions, 12 patients remained with complete series of measurements and sufficient data quality. During day 1, an increase in absolute fetal heart rate variability values was seen. During day 2, a decrease in these values was seen. All trends indicate to return to pre-medication values on day 3. Normalised high- and low-frequency power show little changes during the study period. Conclusions: The changes in fetal heart rate variability following betamethasone administration show the same pattern when calculated by spectral analysis of the fetal electrocardiogram, as when calculated by cardiotocography. Since normalised spectral values show little changes, the influence of autonomic modulation seems minor.\u3c/p\u3