411 research outputs found

    Study of timing properties of single gap high-resistive bakelite RPC

    Full text link
    The time resolution for several single gap (2 mm) prototype Resistive Plate Chambers (RPC) made of high resistive (bulk resistivity ~ 10^10 - 10^12 ohm cm), 2 mm thick matt finished bakelite paper laminates with silicone coating on the inner surfaces, has been measured. The time resolution for all the modules has been found to be ~ 2 ns at the plateau region.Comment: 5 figures, Presented in Frontier Detectors for Frontier Physics (11th Pisa meeting on advanced detectors), La Biodala, Isola d'Elba, Italy, May 24-30, 200

    Event-by-event study of DCC-like fluctuation in ultra-relativistic nuclear collisions

    Full text link
    A method based on sliding window scheme is developed to search for patches in the pseudorapidity-azimuth plane, on an event-by-event basis, having unusual fluctuation in the neutral pion fraction which may arise due to the formation of Disoriented Chrial Condensates (DCC) in high energy nuclear collisions. The efficiency of the method to extract the patches and the purity of the extracted sample are studied for possible experimental situations.Comment: 10 pages, 5 figure

    Performances of linseed oil-free bakelite RPC prototypes with cosmic ray muons

    Full text link
    A comparative study has been performed on Resistive Plate Chambers (RPC) made of two different grades of bakelite paper laminates, produced and commercially available in India. The chambers, operated in the streamer mode using argon, tetrafluroethane and isobutane in 34:59:7 mixing ratio, are tested for the efficiency and the stability with cosmic rays. A particular grade of bakelite (P-120, NEMA LI-1989 Grade XXX), used for high voltage insulation in humid conditions, was found to give satisfactory performance with stable efficiency of > 96% continuously for more than 130 days. A thin coating of silicone fluid on the inner surfaces of the bakelite RPC is found to be necessary for operation of the detector.Comment: 6 figures, Presented in IX International Workshop on Resistive Plate Chamber and related Detectors-2007, TIFR, Mumbai, India, February 13-16, 200

    Performances of silicone coated high resistive bakelite RPC

    Full text link
    Performances of several single gap (gas gap 2 mm) prototype Resistive Plate Chambers (RPC) made of high resistive ({\rho} \sim 1010 - 1012 {\Omega} cm) bakelite, commercially available in India have been studied in recent times. To make the inner electrode surfaces smooth, a thin coating of silicone has been applied. An efficiency > 90% and time resolution \sim 2 ns (FWHM) have been obtained for both the streamer and the avalanche mode. The induced charge distributions of those silicone coated RPC are studied and the results are presented. A numerical study on the effect of surface roughness of the resistive electrodes on the electric field of the device has been carried out using Garfield-neBEM code. A few results for a simplified model representing surface roughness, measured using a surface profilometer for the bakelite surfaces, have also been presented

    A Honeycomb Proportional Counter for Photon Multiplicity Measurement in the ALICE Experiment

    Full text link
    A honeycomb detector consisting of a matrix of 96 closely packed hexagonal cells, each working as a proportional counter with a wire readout, was fabricated and tested at the CERN PS. The cell depth and the radial dimensions of the cell were small, in the range of 5-10 mm. The appropriate cell design was arrived at using GARFIELD simulations. Two geometries are described illustrating the effect of field shaping. The charged particle detection efficiency and the preshower characteristics have been studied using pion and electron beams. Average charged particle detection efficiency was found to be 98%, which is almost uniform within the cell volume and also within the array. The preshower data show that the transverse size of the shower is in close agreement with the results of simulations for a range of energies and converter thicknesses.Comment: To be published in NIM

    Effect of Finite Granularity of Detectors on Anisotropy Coefficients

    Full text link
    The coefficients that describe the anisotropy in the azimuthal distribution of particles are lower when the particles are recorded in a detector with finite granularity and measures only hits. This arises due to loss of information because of multiple hits in any channel. The magnitude of this loss of signal depends both on the occupancy and on the value of the coefficient. These correction factors are obtained for analysis methods differing in detail, and are found to be different.Comment: 11 pages including 2 figure

    The STAR Photon Multiplicity Detector

    Full text link
    Details concerning the design, fabrication and performance of STAR Photon Multiplicity Detector (PMD) are presented. The PMD will cover the forward region, within the pseudorapidity range 2.3--3.5, behind the forward time projection chamber. It will measure the spatial distribution of photons in order to study collective flow, fluctuation and chiral symmetry restoration.Comment: 15 pages, including 11 figures; to appear in a special NIM volume dedicated to the accelerator and detectors at RHI

    Sequential Decay Distortion of Goldhaber Model Widths for Spectator Fragments

    Get PDF
    Momentum widths of the primary fragments and observed final fragments have been investigated within the framework of an Antisymmetrized Molecular Dynamics transport model code (AMD-V) with a sequential decay afterburner (GEMINI). It is found that the secondary evaporation effects cause the values of a reduced momentum width, σ0\sigma_0, derived from momentum widths of the final fragments to be significantly less than those appropriate to the primary fragment but close to those observed in many experiments. Therefore, a new interpretation for experiemental momentum widths of projectile-like fragments is presented.Comment: 4 pages, 3 figs. Accepted for publication in Phys. Rev. C as a Rapid Communicatio

    Sequential Decay Distortion of Goldhaber Model Widths for Spectator Fragments

    Get PDF
    Momentum widths of the primary fragments and observed final fragments have been investigated within the framework of an Antisymmetrized Molecular Dynamics transport model code (AMD-V) with a sequential decay afterburner (GEMINI). It is found that the secondary evaporation effects cause the values of a reduced momentum width, σ0\sigma_0, derived from momentum widths of the final fragments to be significantly less than those appropriate to the primary fragment but close to those observed in many experiments. Therefore, a new interpretation for experiemental momentum widths of projectile-like fragments is presented.Comment: 4 pages, 3 figs. Accepted for publication in Phys. Rev. C as a Rapid Communicatio

    Particle density fluctuations

    Full text link
    Event-by-event fluctuations in the multiplicities of charged particles and photons at SPS energies are discussed. Fluctuations are studied by controlling the centrality of the reaction and rapidity acceptance of the detectors. Results are also presented on the event-by-event study of correlations between the multiplicity of charged particles and photons to search for DCC-like signals.Comment: Talk presented at Quark Matter 2002, Nantes, Franc
    corecore