1,193 research outputs found

    Correlated-photon imaging at 10 volumetric images per second

    Full text link
    The correlation properties of light provide an outstanding tool to overcome the limitations of traditional imaging techniques. A relevant case is represented by correlation plenoptic imaging (CPI), a quantum-inspired volumetric imaging protocol employing spatio-temporally correlated photons from either entangled or chaotic sources to address the main limitations of conventional light-field imaging, namely, the poor spatial resolution and the reduced change of perspective for 3D imaging. However, the application potential of high-resolution imaging modalities relying on photon correlations is limited, in practice, by the need to collect a large number of frames. This creates a gap, unacceptable for many relevant tasks, between the time performance of correlated-light imaging and that of traditional imaging methods. In this article, we address this issue by exploiting the photon number correlations intrinsic in chaotic light, combined with a cutting-edge ultrafast sensor made of a large array of single-photon avalanche diodes (SPADs). This combination of source and sensor is embedded within a novel single-lens CPI scheme enabling to acquire 10 volumetric images per second. Our results place correlated-photon imaging at a competitive edge and prove its potential in practical applications.Comment: 13 pages, 6 figure

    The path from trigeminal asymmetry to cognitive impairment: a behavioral and molecular study

    Get PDF
    Trigeminal input exerts acute and chronic effects on the brain, modulating cognitive functions. Here, new data from humans and animals suggest that these effects are caused by trigeminal influences on the Locus Coeruleus (LC). In humans subjects clenching with masseter asymmetric activity, occlusal correction improved cognition, alongside with reductions in pupil size and anisocoria, proxies of LC activity and asymmetry, respectively. Notably, reductions in pupil size at rest on the hypertonic side predicted cognitive improvements. In adult rats, a distal unilateral section of the trigeminal mandibular branch reduced, on the contralateral side, the expression of c-Fos (brainstem) and BDNF (brainstem, hippocampus, frontal cortex). This counterintuitive finding can be explained by the following model: teeth contact perception loss on the lesioned side results in an increased occlusal effort, which enhances afferent inputs from muscle spindles and posterior periodontal receptors, spared by the distal lesion. Such effort leads to a reduced engagement of the intact side, with a corresponding reduction in the afferent inputs to the LC and in c-Fos and BDNF gene expression. In conclusion, acute effects of malocclusion on performance seem mediated by the LC, which could also contribute to the chronic trophic dysfunction induced by loss of trigeminal input

    SPAD array camera for localization based super resolution microscopy

    Get PDF
    Super resolution microscopy by localization is a stochastic based approach, where the resolution is determined by the localization accuracy [1] [2] [3]. The accuracy of localization heavily depends on the statistics of the data obtained with a camera during imaging. Current state of the art EMCCD (electron multiplying charge coupled device) cameras have frame rates up to 200 fps and hence a limited temporal resolution between frames. This can lead to ambiguities in localization. For example, a single fluorescent spot appearing at the same location in two successive frames is not considered for localization, because it is not clear, whether the spot arises from a single fluorophore in ON state for a long time or from two adjacent fluorophores, which switches ON and OFF. In this work, we explore for the first time the use of a single-photon counting SPAD (single photon avalanche diodes) array camera for super resolution microscopy. These cameras can provide high frame rates (up to 375000 fps), with improved temporal resolution between the frames, enabling a more accurate view of events that can be precisely tracked over time. The rich information obtained from such large number of frames leads to more accurate statistical estimations for overcoming the current ambiguities in localization. Also, SPAD array cameras are capable of reading frames having pixels depth of 1-bit. [4]. Such, a fine granularity enables the user to add any number of frames for identifying and localizing individual events with a very high accuracy. SPADs have been success fully used in performing time-resolved imaging measurements like FLIM (fluorescence life time imaging measurements). This allows us to extend the possibility of performing FLIM and super resolution imaging simultaneously. As a result, two different fluorophores can be separated based on their unique life times, enabling multi-channel operations using a single camera. An example of a preliminary image captured using a SPAD array camera is depicted in Figure

    Another look at the BL Lacertae flux and spectral variability

    Get PDF
    The GLAST-AGILE Support Program (GASP) of the Whole Earth Blazar Telescope (WEBT) monitored BL Lacertae in 2008-2009 at radio, near-IR, and optical frequencies. During this period, high-energy observations were performed by XMM-Newton, Swift, and Fermi. We analyse these data with particular attention to the calibration of Swift UV data, and apply a helical jet model to interpret the source broad-band variability. The GASP-WEBT observations show an optical flare in 2008 February-March, and oscillations of several tenths of mag on a few-day time scale afterwards. The radio flux is only mildly variable. The UV data from both XMM-Newton and Swift seem to confirm a UV excess that is likely caused by thermal emission from the accretion disc. The X-ray data from XMM-Newton indicate a strongly concave spectrum, as well as moderate flux variability on an hour time scale. The Swift X-ray data reveal fast (interday) flux changes, not correlated with those observed at lower energies. We compare the spectral energy distribution (SED) corresponding to the 2008 low-brightness state, which was characterised by a synchrotron dominance, to the 1997 outburst state, where the inverse-Compton emission was prevailing. A fit with an inhomogeneous helical jet model suggests that two synchrotron components are at work with their self inverse-Compton emission. Most likely, they represent the radiation from two distinct emitting regions in the jet. We show that the difference between the source SEDs in 2008 and 1997 can be explained in terms of pure geometrical variations. The outburst state occurred when the jet-emitting regions were better aligned with the line of sight, producing an increase of the Doppler beaming factor. Our analysis demonstrates that the jet geometry can play an extremely important role in the BL Lacertae flux and spectral variability.Comment: 12 pages, 10 figures, accepted for publication in A&

    A Compact Probe for Beta+Emitting Radiotracer Detection in Suregery, Biopsy, and Medical Diagnostics based on Silicon Photomultipliers

    Get PDF
    We present a new probe for radiotracer detection in vivo. The device is based on silicon photomultipliers coupled with a scintillator and wirelessly compensated for supply voltage and temperature variations. The probe is positron sensitive

    Towards quantum 3d imaging devices

    Get PDF
    We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum–position entanglement and photon–number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in standard plenoptic cameras: diffraction-limited resolution, large depth of focus, and ultra-low noise. To further increase the volumetric resolution beyond the Rayleigh diffraction limit, and achieve the quantum limit, we are also developing dedicated protocols based on quantum Fisher information. However, for the quantum advantages of the proposed devices to be effective and appealing to end-users, two main challenges need to be tackled. First, due to the large number of frames required for correlation measurements to provide an acceptable signal-to-noise ratio, quantum plenoptic imaging (QPI) would require, if implemented with commercially available high-resolution cameras, acquisition times ranging from tens of seconds to a few minutes. Second, the elaboration of this large amount of data, in order to retrieve 3D images or refocusing 2D images, requires high-performance and time-consuming computation. To address these challenges, we are developing high-resolution single-photon avalanche photodiode (SPAD) arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim to reduce both the acquisition and the elaboration time by two orders of magnitude. Routes toward exploitation of the QPI devices will also be discussed

    Quality of life in patients with hereditary haemorrhagic telangiectasia (HHT)

    Get PDF
    Background: There are very few studies about general quality of life parameters, standards for the description of health status and comparison with general population data on patients with Hereditary hemorrhagic telangiectasia (HHT), a rare disease in which epistaxis is a cardinal symptom. Purpose: To assess the quality of life in a population of Spanish patients with HHT and compare it with the general population. Design and methods: Between January 1st 2005 and December 31st 2013, 187 adult patients diagnosed with HHT who were admitted to the HHT Unit of the Hospital Sierrallana, completed on their first visit, the EuroQol 5D-3L (five dimensions and three levels) quality of life descriptive test and the visual analog scale (VAS). The numerical social index value was also determined and the subjective effect of the nasal epistaxis on their quality of life was estimated classified as mild, moderate or severe. Results: Patients with HHT had greater problems than the general population in the five dimensions of the EuroQol 5D-3L, particularly considering pain/discomfort and anxiety/depression. In the VAS and the social index value, patients with HHT also scored lower than the general population, particularly older patients, males, and patients with HHT2. They also had values similar to those of populations with chronic illnesses. The subjective perception of the severity of epistaxis correlated strongly with the VAS and social index values. Conclusions: The quality of life of patients with HHT, estimated using the EuroQol 5D-3L scale, is affected across all dimensions. The scores are similar to those seen in cases of other chronic diseases. Older patients, males and the carriers of the ACVRL1 mutation generally have worse scores on these scales. The VAS and the social index value are index that correlate well with the severity of the clinical symptoms associated mainly with epistaxis
    corecore