13 research outputs found

    HCMM energy budget data as a model input for assessing regions of high potential groundwater pollution

    Get PDF
    The author has identified the following significant results. The finite difference model was used to calculate the differences in surface temperature between two hypothetical sites which result from a temperature difference at 50 cm due to the presence of shallow ground water at one of the sites. Although qualitative results of the model seemed consistant with experimental results, further evaluation showed a need for taking account of differences in thermal conductivity due to different moisture profiles at the two sites considered

    HCMM energy budget data as a model input for assessing regions of high potential groundwater pollution

    Get PDF
    The author has identified the following significant results. To investigate the general relationship between surface temperature and soil moisture profiles, a series of model calculations were carried out. Soil temperature profiles were calculated during a complete diurnal cycle for a variety of moisture profiles. Preliminary results indicate the surface temperature difference between two sites measured at about 1400 hours is related to the difference in soil moisture within the diurnal damping depth (about 50 cm). The model shows this temperature difference to vary considerably throughout the diurnal cycle

    Evaluation of HCMM data for assessing soil moisture and water table depth

    Get PDF
    Soil moisture in the 0-cm to 4-cm layer could be estimated with 1-mm soil temperatures throughout the growing season of a rainfed barley crop in eastern South Dakota. Empirical equations were developed to reduce the effect of canopy cover when radiometrically estimating the soil temperature. Corrective equations were applied to an aircraft simulation of HCMM data for a diversity of crop types and land cover conditions to estimate the soil moisture. The average difference between observed and measured soil moisture was 1.6% of field capacity. Shallow alluvial aquifers were located with HCMM predawn data. After correcting the data for vegetation differences, equations were developed for predicting water table depths within the aquifer. A finite difference code simulating soil moisture and soil temperature shows that soils with different moisture profiles differed in soil temperatures in a well defined functional manner. A significant surface thermal anomaly was found to be associated with shallow water tables

    Evaluation of HCMM data for assessing soil moisture and water table depth

    Get PDF
    Data were analyzed for variations in eastern South Dakota. Soil moisture in the 0-4 cm layer could be estimated with 1-mm soil temperatures throughout the growing season of a rainfed barley crop (% cover ranging from 30% to 90%) with an r squared = 0.81. Empirical equations were developed to reduce the effect of canopy cover when radiometrically estimating the 1-mm soil temperature, r squared = 0.88. The corrective equations were applied to an aircraft simulation of HCMM data for a diversity of crop types and land cover conditions to estimate the 0-4 cm soil moisture. The average difference between observed and measured soil moisture was 1.6% of field capacity. HCMM data were used to estimate the soil moisture for four dates with an r squared = 0.55 after correction for crop conditions. Location of shallow alluvial aquifers could be accomplished with HCMM predawn data. After correction of HCMM day data for vegetation differences, equations were developed for predicting water table depths within the aquifer (r=0.8)

    Analysis of the impact resolution has on load matching in the Norwegian context

    No full text
    Generation of energy at building level has an increasing interest in Norway, as in rest of Europe. Load matching is the correlation between the buildings generation and load, which in most cases aims at optimization of the amount of self-consumption. When analysing generation in relation to load, it is of interest to study the choice of resolution and what impact this has on load match indicators. This study analyses the importance of choosing the right resolution, starting with hourly measurements, and going down towards one-minute resolution. Monitoring resolution has a significant impact on both the type of monitoring equipment and the data storage capacity needed. If the impact of lower resolution is small, less complex monitoring systems can be installed in projects that are not sensible to the uncertainty caused by the lack of minute-based data. Norwegian case studies with solar power production gives data to the analysis, studying a nursing home in Oslo called Økern Sykehjem. The nursing home has been a pilot building in the European Fp7 research project ZenN, Nearly Zero Energy Neighbourhood (2012-2017), which led to the installation of 130 kW solar power panels while going through a large renovation process. Generation and load have been monitored with high-resolution since 2015 and this gives useful insight into the effect of high-resolution data monitoring compared to hourly-resolution monitoring. Resulting graphs shows that by collecting data on a daily basis will give a wrong impression on self-consumption and self-generation by about 20% compared to hourly based data. The difference between minute based and hourly based resolution is relatively small (6%)publishedVersio

    Endocytic pathways regulate Toll-like receptor 4 signaling and link innate and adaptive immunity

    No full text
    Immune responses are initiated when molecules of microbial origin are sensed by the Toll-like receptors (TLRs). We now report the identification of essential molecular components for the trafficking of the lipopolysaccharide (LPS) receptor complex. LPS was endocytosed by a receptor-mediated mechanism dependent on dynamin and clathrin and colocalized with TLR4 on early/sorting endosomes. TLR4 was ubiquitinated and associated with the ubiquitin-binding endosomal sorting protein hepatocyte growth factor-regulated tyrosine kinase substrate, Hrs. Inhibition of endocytosis and endosomal sorting increased LPS signaling. Finally, the LPS receptor complex was sorted to late endosomes/lysosomes for degradation and loading of associated antigens onto HLA class II molecules for presentation to CD4(+) T cells. Our results show that endosomal trafficking of the LPS receptor complex is essential for signal termination and LPS-associated antigen presentation, thus controlling both innate and adaptive immunity through TLR4
    corecore