212 research outputs found

    How does it feel to act together?

    Get PDF
    This paper on the phenomenology of joint agency proposes a foray into a little explored territory at the intersection of two very active domains of research: joint action and sense of agency. I explore two ways in which our experience of joint agency may differ from our experience of individual agency. First, the mechanisms of action specification and control involved in joint action are typically more complex than those present in individual actions, since it is crucial for joint action that people coordinate their plans and actions. I discuss the implications that these coordination requirements might have for the strength of the sense of agency an agent may experience for a joint action. Second, engagement in joint action may involve a transformation of agentive identity and a partial or complete shift from a sense of self-agency to a sense of we-agency. I discuss several factors that may contribute to shaping our sense of agentive identity in joint action

    Measurement and interpretation of same-sign W boson pair production in association with two jets in pp collisions at s = 13 TeV with the ATLAS detector

    Get PDF
    This paper presents the measurement of fducial and diferential cross sections for both the inclusive and electroweak production of a same-sign W-boson pair in association with two jets (W±W±jj) using 139 fb−1 of proton-proton collision data recorded at a centre-of-mass energy of √s = 13 TeV by the ATLAS detector at the Large Hadron Collider. The analysis is performed by selecting two same-charge leptons, electron or muon, and at least two jets with large invariant mass and a large rapidity diference. The measured fducial cross sections for electroweak and inclusive W±W±jj production are 2.92 ± 0.22 (stat.) ± 0.19 (syst.)fb and 3.38±0.22 (stat.)±0.19 (syst.)fb, respectively, in agreement with Standard Model predictions. The measurements are used to constrain anomalous quartic gauge couplings by extracting 95% confdence level intervals on dimension-8 operators. A search for doubly charged Higgs bosons H±± that are produced in vector-boson fusion processes and decay into a same-sign W boson pair is performed. The largest deviation from the Standard Model occurs for an H±± mass near 450 GeV, with a global signifcance of 2.5 standard deviations

    Combination of searches for heavy spin-1 resonances using 139 fb−1 of proton-proton collision data at s = 13 TeV with the ATLAS detector

    Get PDF
    A combination of searches for new heavy spin-1 resonances decaying into different pairings of W, Z, or Higgs bosons, as well as directly into leptons or quarks, is presented. The data sample used corresponds to 139 fb−1 of proton-proton collisions at = 13 TeV collected during 2015–2018 with the ATLAS detector at the CERN Large Hadron Collider. Analyses selecting quark pairs (qq, bb, , and tb) or third-generation leptons (τν and ττ) are included in this kind of combination for the first time. A simplified model predicting a spin-1 heavy vector-boson triplet is used. Cross-section limits are set at the 95% confidence level and are compared with predictions for the benchmark model. These limits are also expressed in terms of constraints on couplings of the heavy vector-boson triplet to quarks, leptons, and the Higgs boson. The complementarity of the various analyses increases the sensitivity to new physics, and the resulting constraints are stronger than those from any individual analysis considered. The data exclude a heavy vector-boson triplet with mass below 5.8 TeV in a weakly coupled scenario, below 4.4 TeV in a strongly coupled scenario, and up to 1.5 TeV in the case of production via vector-boson fusion

    Search for dark photons in rare Z boson decays with the ATLAS detector

    Get PDF
    A search for events with a dark photon produced in association with a dark Higgs boson via rare decays of the standard model Z boson is presented, using 139     fb − 1 of √ s = 13     TeV proton-proton collision data recorded by the ATLAS detector at the Large Hadron Collider. The dark boson decays into a pair of dark photons, and at least two of the three dark photons must each decay into a pair of electrons or muons, resulting in at least two same-flavor opposite-charge lepton pairs in the final state. The data are found to be consistent with the background prediction, and upper limits are set on the dark photon’s coupling to the dark Higgs boson times the kinetic mixing between the standard model photon and the dark photon, α D ϵ 2 , in the dark photon mass range of [5, 40] GeV except for the Υ mass window [8.8, 11.1] GeV. This search explores new parameter space not previously excluded by other experiments

    Combined measurement of the Higgs boson mass from the H → γγ and H → ZZ∗ → 4ℓ decay channels with the ATLAS detector using √s = 7, 8, and 13 TeV pp collision data

    Get PDF
    A measurement of the mass of the Higgs boson combining the H → Z Z ∗ → 4 ℓ and H → γ γ decay channels is presented. The result is based on 140     fb − 1 of proton-proton collision data collected by the ATLAS detector during LHC run 2 at a center-of-mass energy of 13 TeV combined with the run 1 ATLAS mass measurement, performed at center-of-mass energies of 7 and 8 TeV, yielding a Higgs boson mass of 125.11 ± 0.09 ( stat ) ± 0.06 ( syst ) = 125.11 ± 0.11     GeV . This corresponds to a 0.09% precision achieved on this fundamental parameter of the Standard Model of particle physics

    Contaminação bacteriana em concentrados plaquetários: identificação, perfil de sensibilidade aos antimicrobianos e sepse associada à transfusão Bacterial contamination on platelet concentrates: identification, antimicrobial susceptibility profile and transfusion-related sepsis

    No full text
    INTRODUÇÃO: Devido à sepse bacteriana associada à transfusão de concentrados plaquetários (CPs) ter sérias consequências clínicas para os pacientes, alguns procedimentos têm sido incorporados na preparação e no controle de qualidade dos componentes sanguíneos para reduzir o risco da contaminação bacteriana. Este artigo descreve a prevalência da contaminação bacteriana dos CPs que foram transfundidos, o espectro bacteriano detectado com seu perfil de sensibilidade aos antimicrobianos e as reações transfusionais nos receptores. MÉTODOS: Um total de 292 CPs (278 randômicos e 14 por aférese), proveniente do Hemocentro do Estado do Rio Grande do Sul (HEMORGS) de Santa Maria foi testado. As quantidades de 100&#956;L e 200&#956;L foram coletadas da porção tubular da bolsa de plaquetas e semeadas utilizando dois tipos de metodologias. RESULTADOS: Em cinco unidades(1,7%; 5/292) foram isoladas bactérias pela metodologia qualitativa e apenas uma pela quantitativa. Staphylococcus epidermidis foi o microrganismo identificado em todas as amostras. Dois pacientes apresentaram sepse associada à transfusão com desfecho fatal. CONCLUSÕES: A contaminação bacteriana pelas transfusões de CPs constitui-se num importante problema de saúde pública devido a sua associação com altas taxas de morbidade e mortalidade. Neste estudo, somente microrganismos gram-positivos foram isolados sendo que nenhuma amostra obtida por aférese apresentou contaminação.<br>INTRODUCTION: Bacterial sepsis associated with the transfusion of platelet concentrates (PCs) results in serious clinical implications for patients. Given these implications, certain procedures have been integrated into the preparation and quality control of blood components to reduce the risk of bacterial contamination. This article describes the prevalence of bacterial contamination on transfused PCs, the bacterial spectrum detected and their antimicrobial susceptibility profile and transfusion reactions in receptors. METHODS: A total of 292 PCs (278 random and 14 per apheresis) from the Blood Center of the State of Rio Grande do Sul (HEMORGS), located in the city of Santa Maria, were tested. Quantities of 100&#956;L and 200&#956;L were collected from platelet bag tubing and seeded using two methodologies. RESULTS: Using the qualitative methodology, bacteria were isolated in five units (1.7%; 5/292), while only one was isolated using the quantitative methodology. Staphylococcus epidermidis was the microorganism identified in all samples. Two patients died of transfusion-related sepsis. CONCLUSIONS: Bacterial contamination due to PC transfusion is considered a major public health problem due to its association with high rates of morbidity and mortality. In this study only gram-positive microorganisms were isolated and none of the samples obtained by apheresis presented contamination
    corecore