52 research outputs found

    Transducers for the determination of the pressure and shear stress distribution at the stump-socket interface of trans-tibial amputees

    Get PDF
    Recent developments in prosthetic socket design have created renewed interest in monitoring the stress distribution at the socket-residual limb interface. Although a few devices for measuring pressure can be found in the literature, none are capable of measuring reliably in areas of high curvature, such as the important area at the patellar tendon bar. Furthermore, few devices can record shear stress, thought to be critical in causing tissue damage. In order to address these issues two new transducers have been designed and evaluated. One design allows the simultaneous recording of the normal and shear stresses at various points of the socket walls, while the other is capable of measuring the three components of the force applied on the patellar tendon. The latter design incorporates a feature that permits displacement of the patellar tendon bar, in order to study the effect of various amounts of indentation of the tendon on the stress distribution around the residual limb. Both transducers were calibrated using dead weights and special jigs to ensure accurate loading conditions. Under laboratory bench conditions the normal-shear force transducer showed: 2.03 per cent full scale output (FSO) hysteresis error for shear stress direction, 1.65 per cent FSO for normal direction; 99.56 per cent FSO overall accuracy for shear direction, and within 99.64 per cent FSO for normal direction; and for the patellar tendon transducer 1.53 per cent FSO hysteresis error for shear direction, 1.85 per cent FSO for shear stress direction; 99.65 per cent FSO overall accuracy for shear direction, and 99.58 per cent FSO for normal direction. During an amputee walking trial the transducers showed 92 per cent to 97 per cent repeatability. The two new transducers were used in conjunction with two other types of transducers, previously designed at the University of Strathclyde, in a series of tests on ten trans-tibial amputees. Sample results for walking activities and a summary of maximum stresses recorded are presented

    The Earth: Plasma Sources, Losses, and Transport Processes

    Get PDF
    This paper reviews the state of knowledge concerning the source of magnetospheric plasma at Earth. Source of plasma, its acceleration and transport throughout the system, its consequences on system dynamics, and its loss are all discussed. Both observational and modeling advances since the last time this subject was covered in detail (Hultqvist et al., Magnetospheric Plasma Sources and Losses, 1999) are addressed

    The Cholecystectomy As A Day Case (CAAD) Score: A Validated Score of Preoperative Predictors of Successful Day-Case Cholecystectomy Using the CholeS Data Set

    Get PDF
    Background Day-case surgery is associated with significant patient and cost benefits. However, only 43% of cholecystectomy patients are discharged home the same day. One hypothesis is day-case cholecystectomy rates, defined as patients discharged the same day as their operation, may be improved by better assessment of patients using standard preoperative variables. Methods Data were extracted from a prospectively collected data set of cholecystectomy patients from 166 UK and Irish hospitals (CholeS). Cholecystectomies performed as elective procedures were divided into main (75%) and validation (25%) data sets. Preoperative predictors were identified, and a risk score of failed day case was devised using multivariate logistic regression. Receiver operating curve analysis was used to validate the score in the validation data set. Results Of the 7426 elective cholecystectomies performed, 49% of these were discharged home the same day. Same-day discharge following cholecystectomy was less likely with older patients (OR 0.18, 95% CI 0.15–0.23), higher ASA scores (OR 0.19, 95% CI 0.15–0.23), complicated cholelithiasis (OR 0.38, 95% CI 0.31 to 0.48), male gender (OR 0.66, 95% CI 0.58–0.74), previous acute gallstone-related admissions (OR 0.54, 95% CI 0.48–0.60) and preoperative endoscopic intervention (OR 0.40, 95% CI 0.34–0.47). The CAAD score was developed using these variables. When applied to the validation subgroup, a CAAD score of ≤5 was associated with 80.8% successful day-case cholecystectomy compared with 19.2% associated with a CAAD score >5 (p < 0.001). Conclusions The CAAD score which utilises data readily available from clinic letters and electronic sources can predict same-day discharges following cholecystectomy

    Long-term monitoring of activity in the below knee amputee

    No full text
    Paper focusing on the long-term monitoring of activity in the below knee amputee

    Load sharing capability of a quadrilateral socket for a trans-femoral amputee

    No full text
    Paper examining load sharing capability of a quadrilateral socket for a trans-femoral amputee

    FE model of a trans-femoral prosthetic socket

    No full text
    Paper discussing the application of a two part limb/socket finite element (FE) model to model socket donning

    Comparing the load distribution between quadrilateral and IC trans-femoral sockets

    No full text
    Paper investigating the degree of load sharing between the ischial brim and the rest of the socket for the ischial containment (IC) and quadrilateral (Quad) socket designs

    Comparison of different material properties in an idealised FEM of socket donning

    No full text
    Paper comparing different material properties in an idealised FEM of socket donning

    Modelling of the residual limb of trans-femoral amputees using finite element analysis

    No full text
    Paper concerning the modelling of the residual limb of trans-femoral amputees using finite element analysis

    Measurements of the interface pressure between the stump and the socket and its relevance to the prosthetic socket design

    No full text
    Paper concerned with measurements of the interface pressure between the stump and the socket and its relevance to the prosthetic socket design
    corecore