55 research outputs found

    The InfraRed Imaging Spectrograph (IRIS) for TMT: photometric precision and ghost analysis

    Get PDF
    The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive optics field by NFIRAOS with a near-infrared (0.8 - 2.4 μ\mum) imaging camera and Integral Field Spectrograph (IFS). In order to understand the science case specifications of the IRIS instrument, we use the IRIS data simulator to characterize photometric precision and accuracy of the IRIS imager. We present the results of investigation into the effects of potential ghosting in the IRIS optical design. Each source in the IRIS imager field of view results in ghost images on the detector from IRIS's wedge filters, entrance window, and Atmospheric Dispersion Corrector (ADC) prism. We incorporated each of these ghosts into the IRIS simulator by simulating an appropriate magnitude point source at a specified pixel distance, and for the case of the extended ghosts redistributing flux evenly over the area specified by IRIS's optical design. We simulate the ghosting impact on the photometric capabilities, and found that ghosts generally contribute negligible effects on the flux counts for point sources except for extreme cases where ghosts coalign with a star of Δ\Deltam>>2 fainter than the ghost source. Lastly, we explore the photometric precision and accuracy for single sources and crowded field photometry on the IRIS imager.Comment: SPIE 2018, 14 pages, 14 figures, 4 tables, Proceedings of SPIE 10702-373, Ground-based and Airborne Instrumentation for Astronomy VII, 10702A7 (16 July 2018

    The Infrared Imaging Spectrograph (IRIS) for TMT: motion planning with collision avoidance for the on-instrument wavefront sensors

    Get PDF
    The InfraRed Imaging Spectrograph (IRIS) will be a first-light client instrument for the Narrow Field Infrared Adaptive Optics System (NFIRAOS) on the Thirty Meter Telescope. IRIS includes three configurable tip/tilt (TT) or tip/tilt/focus (TTF) On-Instrument Wavefront Sensors (OIWFS). These sensors are positioned over natural guide star (NGS) asterisms using movable polar-coordinate pick-ofi arms (POA) that patrol an approximately 2-arcminute circular field-of-view (FOV). The POAs are capable of colliding with one another, so an algorithm for coordinated motion that avoids contact is required. We have adopted an approach in which arm motion is evaluated using the gradient descent of a scalar potential field that includes an attractive component towards the goal configuration (locations of target stars), and repulsive components to avoid obstacles (proximity to adjacent arms). The resulting vector field is further modified by adding a component transverse to the repulsive gradient to avoid problematic local minima in the potential. We present path planning simulations using this computationally inexpensive technique, which exhibit smooth and efficient trajectories

    An overview of the NIRSPEC upgrade for the Keck II telescope

    Full text link
    NIRSPEC is a 1-5 micron echelle spectrograph in use on the Keck II Telescope since 1999. The spectrograph is capable of both moderate (R~2,000) and high (R~25,000) resolution observations and has been a workhorse instrument across many astronomical fields, from planetary science to extragalactic observations. In the latter half of 2018, we will upgrade NIRSPEC to improve the sensitivity and stability of the instrument and increase its lifetime. The major components of the upgrade include replacing the spectrometer and slit-viewing camera detectors with Teledyne H2RG arrays and replacing all transputer-based electronics. We present detailed design, testing, and analysis of the upgraded instrument, including the finalized optomechanical design of the new 1-5 micron slit-viewing camera, final alignment and assembly of the science array, electronics systems, and updated software design.Comment: Proceedings of the 2018 SPIE Astronomical Telescopes & Instrumentatio

    The Infrared Imaging Spectrograph (IRIS) for TMT: Instrument Overview

    Full text link
    We present an overview of the design of IRIS, an infrared (0.84 - 2.4 micron) integral field spectrograph and imaging camera for the Thirty Meter Telescope (TMT). With extremely low wavefront error (<30 nm) and on-board wavefront sensors, IRIS will take advantage of the high angular resolution of the narrow field infrared adaptive optics system (NFIRAOS) to dissect the sky at the diffraction limit of the 30-meter aperture. With a primary spectral resolution of 4000 and spatial sampling starting at 4 milliarcseconds, the instrument will create an unparalleled ability to explore high redshift galaxies, the Galactic center, star forming regions and virtually any astrophysical object. This paper summarizes the entire design and basic capabilities. Among the design innovations is the combination of lenslet and slicer integral field units, new 4Kx4k detectors, extremely precise atmospheric dispersion correction, infrared wavefront sensors, and a very large vacuum cryogenic system.Comment: Proceedings of the SPIE, 9147-76 (2014

    The InfraRed Imaging Spectrograph (IRIS) for TMT: photometric characterization of anisoplanatic PSFs and testing of PSF-Reconstruction via AIROPA

    Get PDF
    The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive optics field by the Narrow-Field Infrared Adaptive Optics System (NFIRAOS) with a near-infrared (0.8 - 2.4 µm) imaging camera and integral field spectrograph. To better understand IRIS science specifications we use the IRIS data simulator to characterize relative photometric precision and accuracy across the IRIS imaging camera 34”x34” field of view. Because the Point Spread Function (PSF) varies due to the effects of anisoplanatism, we use the Anisoplanatic and Instrumental Reconstruction of Off-axis PSFs for AO (AIROPA) software package to conduct photometric measurements on simulated frames using PSF-fitting as the PSF varies in single-source, binary, and crowded field use cases. We report photometric performance of the imaging camera as a function of the instrumental noise properties including dark current and read noise. Using the same methods, we conduct comparisons of photometric performance with reconstructed PSFs, in order to test the veracity of the current PSF-Reconstruction algorithms for IRIS/TMT

    The Infrared Imaging Spectrograph (IRIS) for TMT: final design development of the data reduction system

    Get PDF
    IRIS (Infrared Imaging Spectrograph) is the near-infrared (0.84 to 2.4 micron) diffraction-limited imager and Integral Field Spectrograph (IFS) designed for the Thirty Meter Telescope (TMT) and the Narrow-Field Infrared Adaptive Optics System ( NFIRAOS ). The imager will have a 34 arcsec x 34 arcsec field of view with 4 milliarcseconds (mas) pixels. The IFS consists of a lenslet array and slicer, enabling four plate scales from 4 mas to 50 mas, with multiple gratings and filters. We will report the progress on the development of the IRIS Data Reduction System ( DRS ) in the final design phase. The IRIS DRS is being developed in Python with the software architecture based on the James Webb Space Telescope science calibration pipeline. We are developing a library of algorithms as individual Python classes that can be configured independently and bundled into pipelines. We will interface this with the observatory software to run online during observations and we will release the package publicly for scientists to develop custom analyses. It also includes a C library for readout processing to be used for both in real-time processing (e.g., up-the-ramp, MCDS) as well the ability for astronomers to use for offline reduction. Lastly, we will also discuss the development of the IRIS simulation packages that simulate raw spectra and image readout-data from the Hawaii-4RG detectors, which helps in developing reduction algorithms during this design phase
    corecore