The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the
Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive
optics field by NFIRAOS with a near-infrared (0.8 - 2.4 μm) imaging camera
and Integral Field Spectrograph (IFS). In order to understand the science case
specifications of the IRIS instrument, we use the IRIS data simulator to
characterize photometric precision and accuracy of the IRIS imager. We present
the results of investigation into the effects of potential ghosting in the IRIS
optical design. Each source in the IRIS imager field of view results in ghost
images on the detector from IRIS's wedge filters, entrance window, and
Atmospheric Dispersion Corrector (ADC) prism. We incorporated each of these
ghosts into the IRIS simulator by simulating an appropriate magnitude point
source at a specified pixel distance, and for the case of the extended ghosts
redistributing flux evenly over the area specified by IRIS's optical design. We
simulate the ghosting impact on the photometric capabilities, and found that
ghosts generally contribute negligible effects on the flux counts for point
sources except for extreme cases where ghosts coalign with a star of
Δm>2 fainter than the ghost source. Lastly, we explore the photometric
precision and accuracy for single sources and crowded field photometry on the
IRIS imager.Comment: SPIE 2018, 14 pages, 14 figures, 4 tables, Proceedings of SPIE
10702-373, Ground-based and Airborne Instrumentation for Astronomy VII,
10702A7 (16 July 2018