215 research outputs found

    Spherical harmonic based noise rejection and neuronal sampling with multi-axis OPMs

    Get PDF
    In this study we explore the interference rejection and spatial sampling properties of multi-axis Optically Pumped Magnetometer (OPM) data. We use both vector spherical harmonics and eigenspectra to quantify how well an array can separate neuronal signal from environmental interference while adequately sampling the entire cortex. We found that triaxial OPMs have superb noise rejection properties allowing for very high orders of interference (L=6) to be accounted for while minimally affecting the neural space (2dB attenuation for a 60-sensor triaxial system). We show that at least 11th order (143 spatial degrees of freedom) irregular solid harmonics or 95 eigenvectors of the lead field are needed to model the neural space for OPM data (regardless of number of axes measured). This can be adequately sampled with 75-100 equidistant triaxial sensors (225-300 channels) or 200 equidistant radial channels. In other words, ordering the same number of channels in triaxial (rather than purely radial) configuration may give significant advantages not only in terms of external noise rejection but also by minimizing cost, weight and cross-talk

    Satellite Tracking and Site Fidelity of Short Ocean Sunfish, Mola ramsayi, in the Galapagos Islands

    Get PDF
    Ocean sunfishes, with their peculiar morphology, large size, and surface habits, are valuable assets in ecotourism destinations worldwide. This study investigates site fidelity and long-range movements of short ocean sunfish, Mola ramsayi (Giglioli 1883), at Punta Vicente Roca (PVR) off Isabela Island in the Galapagos Islands. Five individuals were tracked between 32 and 733 days using ultrasonic receivers and transmitters. Two of the 5 were also tracked with towed pop-off satellite tags. One travelled to the equatorial front covering 2700 km in 53 days, with dive depths in the upper 360 m at temperatures between 9.2°C and 22°C. During its westward travel, dives extended to 1112 m (the deepest depth yet recorded for Molidae) into temperatures ranging between 4.5°C and 23.2°C. The remaining four individuals demonstrated site fidelity to PVR and were detected at the site between 128–1361 times for a total of 3557 reports. Forty-eight percent of the reports occurred during daytime hours and 52% after dark. Presumed cleaning session durations had a median of 15 minutes and a maximum of nearly 100 minutes. No other ultrasonic arrays around Galapagos or in the Eastern Pacific regional network recorded the presence of tagged individuals. These data are combined with tourist vessel sightings and submersible observations to confirm Punta Vicente Roca as an important sunfish hotspot

    Real-time, model-based magnetic field correction for moving, wearable MEG

    Get PDF
    Most neuroimaging techniques require the participant to remain still for reliable recordings to be made. Optically pumped magnetometer (OPM) based magnetoencephalography (OP-MEG) however, is a neuroimaging technique which can be used to measure neural signals during large participant movement (approximately 1 m) within a magnetically shielded room (MSR) (Boto et al., 2018; Seymour et al., 2021). Nevertheless, environmental magnetic fields vary both spatially and temporally and OPMs can only operate within a limited magnetic field range, which constrains participant movement. Here we implement real-time updates to electromagnetic coils mounted on-board of the OPMs, to cancel out the changing background magnetic fields. The coil currents were chosen based on a continually updating harmonic model of the background magnetic field, effectively implementing homogeneous field correction (HFC) in real-time (Tierney et al., 2021). During a stationary, empty room recording, we show an improvement in very low frequency noise of 24 dB. In an auditory paradigm, during participant movement of up to 2 m within a magnetically shielded room, introduction of the real-time correction more than doubled the proportion of trials in which no sensor saturated recorded outside of a 50 cm radius from the optimally-shielded centre of the room. The main advantage of such model-based (rather than direct) feedback is that it could allow one to correct field components along unmeasured OPM axes, potentially mitigating sensor gain and calibration issues (Borna et al., 2022)

    Optically pumped magnetometers: From quantum origins to multi-channel magnetoencephalography

    Get PDF
    Optically Pumped Magnetometers (OPMs) have emerged as a viable and wearable alternative to cryogenic, superconducting MEG systems. This new generation of sensors has the advantage of not requiring cryogenic cooling and as a result can be flexibly placed on any part of the body. The purpose of this review is to provide a neuroscience audience with the theoretical background needed to understand the physical basis for the signal observed by OPMs. Those already familiar with the physics of MRI and NMR should note that OPMs share much of the same theory as the operation of OPMs rely on magnetic resonance. This review establishes the physical basis for the signal equation for OPMs. We re-derive the equations defining the bounds on OPM performance and highlight the important trade-offs between quantities such as bandwidth, sensor size and sensitivity. These equations lead to a direct upper bound on the gain change due to cross-talk for a multi-channel OPM system

    Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography

    Get PDF
    One of the most severe limitations of functional neuroimaging techniques, such as magnetoencephalography (MEG), is that participants must maintain a fixed head position during data acquisition. This imposes restrictions on the characteristics of the experimental cohorts that can be scanned and the experimental questions that can be addressed. For these reasons, the use of ‘wearable’ neuroimaging, in which participants can move freely during scanning, is attractive. The most successful example of wearable neuroimaging is electroencephalography (EEG), which employs lightweight and flexible instrumentation that makes it useable in almost any experimental setting. However, EEG has major technical limitations compared to MEG, and therefore the development of wearable MEG, or hybrid MEG/EEG systems, is a compelling prospect. In this paper, we combine and compare EEG and MEG measurements, the latter made using a new generation of optically-pumped magnetometers (OPMs). We show that these new second generation commercial OPMs, can be mounted on the scalp in an ‘EEG-like’ cap, enabling the acquisition of high fidelity electrophysiological measurements. We show that these sensors can be used in conjunction with conventional EEG electrodes, offering the potential for the development of hybrid MEG/EEG systems. We compare concurrently measured signals, showing that, whilst both modalities offer high quality data in stationary subjects, OPM-MEG measurements are less sensitive to artefacts produced when subjects move. Finally, we show using simulations that OPM-MEG offers a fundamentally better spatial specificity than EEG. The demonstrated technology holds the potential to revolutionise the utility of functional brain imaging, exploiting the flexibility of wearable systems to facilitate hitherto impractical experimental paradigms

    Fertility History and Cognition in Later Life

    Get PDF
    Objectives To investigate the association between fertility history and cognition in older men and women. Method We analyzed associations between number of children (parity) and timing of births with level and change in cognition among 11,233 men and women aged 50+ in England using latent growth curve models. Models were adjusted for age, socioeconomic position, health, depressive symptoms, control, social contacts, activities, and isolation. Results Low (0–1 child) and high parity (3+ children) compared to medium parity (2 children) were associated with poorer cognitive functioning, as was an early age at entry to parenthood (35) was associated with better cognitive function. Conclusion Associations between fertility history and cognition were to large extent accounted for socioeconomic position, partly because this influenced health and social engagement. Poorer cognition in childless people and better cognition among mothers experiencing child birth at higher ages suggest factors related to childbearing/rearing that are beneficial for later cognitive functioning, although further research into possible earlier selection factors is needed

    A bi-planar coil system for nulling background magnetic fields in scalp mounted magnetoencephalography

    Get PDF
    Small, commercially-available Optically Pumped Magnetometers (OPMs) can be used to construct a wearable Magnetoencephalography (MEG) system that allows large head movements to be made during recording. The small dynamic range of these sensors however means that movement in the residual static magnetic field found inside typical Magnetically Shielded Rooms (MSR) can saturate the sensor outputs, rendering the data unusable. This problem can be ameliorated by using a set of electromagnetic coils to attenuate the spatially-varying remnant field. Here, an array of bi-planar coils, which produce an open and accessible scanning environment, were designed and constructed. The coils were designed using a harmonic minimisation method previously used for gradient coil design in Magnetic Resonance Imaging (MRI). Six coils were constructed to nul

    Balanced, bi-planar magnetic field and field gradient coils for field compensation in wearable magnetoencephalography

    Get PDF
    To allow wearable magnetoencephalography (MEG) recordings to be made on unconstrained subjects the spatially inhomogeneous remnant magnetic field inside the magnetically shielded room (MSR) must be nulled. Previously, a large bi-planar coil system which produces uniform fields and field gradients was used for this purpose. Its construction presented a significant challenge, six distinct coils were wound on two 1.6 x 1.6 m2 planes. Here, we exploit shared coil symmetries to produce coils simultaneously optimised to generate homogenous fields and gradients. We show nulling performance comparable to that of a sixcoil system is achieved with this three-coil system, decreasing the strongest field component Bx by a factor of 53, and the strongest gradient dBx/dz by a factor of 7. To allow the coils to be used in environments with temporally-varying magnetic interference a dynamic nulling system was developed with a shielding factor of 40 dB at 0.01 Hz. Reducing the number of coils required and incorporating dynamic nulling should allow for greater take-up of this technology. Interactions of the coils with the high-permeability walls of the MSR were investigated using a method of images approach. Simulations show a degrading of field uniformity which was broadly consistent with measured values. These effects should be incorporated into future designs
    • …
    corecore