46 research outputs found

    A newly discovered membrane at the origin of the proximal tendinous complex of the rectus femoris

    Get PDF
    Acord transformatiu CRUE-CSICPurpose: The rectus femoris (RF) forms the anterior portion of the quadriceps muscle group. It has a proximal tendinous complex (PTC) which is constituted by a direct tendon (DT), an indirect tendon (IT), and a variable third head. Direct and indirect tendons finally converge into a common tendon (CT). All the PTC shows a medially sloping in its proximal insertion.We investigated several anatomical specimens and discovered a new component: a membrane connecting the CT with the anterior superior iliac spine. Such membrane constitutes a new origin of the PTC. The aim of this study was to clarify whether this membrane was an anatomical variation of the PTC or a constant structure and to describe its morphology and trajectory. Material and methods: We dissected 42 cadaveric lower limbs and examined the architecture of the PTC. We paid special attention to the morphology and interaction patterns between the tendons and the membrane. Results: We demonstrated that the membrane is a constant component of the PTC. It has a lateral to medial trajectory and is in relation to the common tendon, the DT, and IT, which present a medial slope. This suggests that the membrane has an stabilizer role for the PTC, acting as a corrector of the inclined vector of the complex. Conclusion: The RF injuries are frequent in football. The newly discovered membrane is a constant component of the PTC and its integrity should be included in the algorithm to diagnose injuries

    Fascicular Topography of the Human Median Nerve for Neuroprosthetic Surgery

    Get PDF
    One of the most sought-after applications of neuroengineering is the communication between the arm and an artificial prosthetic device for the replacement of an amputated hand or the treatment of peripheral nerve injuries. For that, an electrode is placed around or inside the median nerve to serve as interface for recording and stimulation of nerve signals coming from the fascicles that innervate the muscles responsible for hand movements. Due to the lack of a standard procedure, the electrode implantation by the surgeon is strongly based on intuition, which may result in poor performance of the neuroprosthesis because of the suboptimal location of the neural interface. To provide morphological data that can aid the neuroprosthetic surgeon with this procedure, we investigated the fascicular topography of the human median nerve along the forearm and upper arm. We first performed a description of the fascicular content and branching patterns along the length of the arm. Next we built a 3D reconstruction of the median nerve so we could analyze the fascicle morphological features in relation to the arm level. Finally, we characterized the motor content of the median nerve fascicles in the upper arm. Collectively, these results indicate that fascicular organization occurs in a short segment distal to the epicondyles and remains unaltered until the muscular branches leave the main trunk. Based on our results, overall recommendations based on electrode type and implant location can be drawn to help and aid the neuroprosthetic procedure. Invasive interfaces would be more convenient for the upper arm and the most proximal third of the forearm. Epineural electrodes seem to be most suitable for the forearm segment after fascicles have been divided from the main trunk

    Precision and safety of Multilevel Cervical Transpedicular Screw Fixation with 3D Patient-Specific Guides; A Cadaveric Study

    Get PDF
    The aim is to design a patient-specific instrument (PSI) for multilevel cervical pedicle screw placement from C2 to C7, as well as verifying reliability and reproducibility. Computed tomography (CT) scans were obtained from 7 cadaveric cervical spines. Using Mimics software, semiautomatic segmentation was performed for each cervical spine, designing a 3D cervical spine bone model in order to plan transpedicular screw fixation. A PSI was designed according to the previously cited with two cannulated chimneys to guide the drill. The guides were 3D printed and surgeries performed at the laboratory. Postoperative scans were obtained to study screw placement. Sixty-eight transpedicular screws were available for study. 61.8% of all screws were within the pedicle or partially breached <4 mm. No differences were observed between cervical levels. None of these screws had neurovascular injury. Of the 27 screws with a grade 3 (screw outside the pedicle; 39.7%), only 2 had perforation of the transverse foramen and none of them would have caused a neural injury. In conclusion, multilevel PSI for cervical pedicle screw is a promising technology that despite showing improvements regarding free-hand technique requires further studies to improve the positioning of the PSI and their accuracy

    Estudi de les entesis per a la identificació forense

    Get PDF
    El Grup de Recerca en Osteobiografia de la UAB ha dut a terme un estudi de les entesis -punts d'unió entre el muscle i l'os- dels radis de més de vuitanta esquelets humans per tal de conèixer els canvis morfològics produïts al llarg de la seva vida i esbrinar-ne la causa. La metodologia emprada pels investigadors pot contribuir en un futur a diferents ciències i perspectives, com ara la identificació d'individus en una necroidentificació forense.El Grupo de Investigación en Osteobiografía de la UAB ha llevado a cabo un estudio de las entesis -puntos de unión entre el músculo y el hueso- de los radios de más de ochenta esqueletos humanos para conocer los cambios morfológicos producidos a lo largo de su vida y la causa de los mismos. La metodología utilizada por los investigadores puede contribuir en un futuro a diferentes ciencias y perspectivas, como por ejemplo la identificación de individuos en una necroidentificación forense

    Decreased endostatin in db/db retinas is associated with optic disc intravitreal vascularization

    Get PDF
    Diabetic retinopathy; Endostatin; Intravitreal vesselsRetinopatia diabètica; Endostatina; Vasos intravítresRetinopatía diabética; Endostatina; Vasos intravítreosEndostatin, a naturally cleaved fragment of type XVIII collagen with antiangiogenic activity, has been involved in the regulation of neovascularization during diabetic retinopathy. Here, the intracellular distribution of endostatin in healthy mouse and human neuroretinas has been analyzed. In addition, to study the effect of experimental hyperglycemia on retinal endostatin, the db/db mouse model has been used. Endostatin protein expression in mouse and human retinas was studied by immunofluorescence and Western blot, and compared with db/db mice. Eye fundus angiography, histology, and immunofluorescence were used to visualize mouse retinal and intravitreal vessels. For the first time, our results revealed the presence of endostatin in neurons of mouse and human retinas. Endostatin was mainly expressed in bipolar cells and photoreceptors, in contrast to the optic disc, where endostatin expression was undetectable. Diabetic mice showed a reduction of endostatin in their retinas associated with the appearance of intravitreal vessels at the optic disc in 50% of db/db mice. Intravitreal vessels showed GFAP positive neuroglia sheath, basement membrane thickening by collagen IV deposition, and presence of MMP-2 and MMP-9 in the vascular wall. All together, these results point that decreased retinal endostatin during experimental diabetes is associated with optic disc intravitreal vascularization. Based on their phenotype, these intravitreal vessels could be neovessels. However, it cannot be ruled out the possibility that they may also represent persistent hyaloid vessels.This work was supported by the Instituto de Salud Carlos III, Ministerio de Ciencia e Innovación, Spain (grant number PI16/00719); the Fundação para a Ciência e a Tecnologia, Ministerio da Educação e Ciência, Portugal (grant numbers SFRH/BD/95330/2013 and SFRH/BPD/102573/2014); and Fondo Europeo de Desarrollo Regional (FEDER)

    Measuring direct and indirect tendon parameters to characterize the proximal tendinous complex of the rectus femoris in football and futsal players

    Get PDF
    To present unprecedented radiological parameters that characterize the angle between the direct and indirect tendons of the proximal rectus femoris (RF) and its inclinations and to evaluate the population variability according to demographic variables. From September 2019 to July 2021, using MRI multiplanar reconstructions of the proximal thigh/hip, two blinded radiologists measured the direct and indirect tendon angle and the inclination of each tendon in different planes. The intra- and inter-observer agreements were assessed with Bland-Altman analysis and intraclass correlation coefficient (ICC). The correlations between radiological parameters and demographic variables were evaluated using linear regression, Student's t- test, and analysis of variance. We performed 112 thigh/hip MRI scans on 91 football players of different age, gender, and disciplines (football and futsal). For observer 1 (the reference), the mean direct and indirect tendon angle was 56.74° ± 9.37, the mean indirect tendon slope was −7.90° ± 7.49, and the mean direct tendon slope was 22.16° ± 5.88. The three measurements showed inter- and intra-observer agreement (mean differences ∼0). No correlation was observed between age and the parameters. Likewise, no statistically significant differences were found for gender, dominant limb, examined limb, and sport. There is an inter- and intra-observer agreement in the measurements of the direct and indirect tendon angle and the inclination of each tendon. There is population variability in the proximal tendinous complex unrelated to demographic factors. These results allow further detection of morphological patterns that represent a risk factor for lesions in the RF in professional football and futsal players and other sports

    Decreased endostatin in db/db retinas is associated with optic disc intravitreal vascularization

    Get PDF
    Research Areas: OphthalmologyABSTRACT - Endostatin, a naturally cleaved fragment of type XVIII collagen with antiangiogenic activity, has been involved in the regulation of neovascularization during diabetic retinopathy. Here, the intracellular distribution of endostatin in healthy mouse and human neuroretinas has been analyzed. In addition, to study the effect of experimental hyperglycemia on retinal endostatin, the db/db mouse model has been used. Endostatin protein expression in mouse and human retinas was studied by immunofluorescence and Western blot, and compared with db/db mice. Eye fundus angiography, histology, and immunofluorescence were used to visualize mouse retinal and intravitreal vessels. For the first time, our results revealed the presence of endostatin in neurons of mouse and human retinas. Endostatin was mainly expressed in bipolar cells and photoreceptors, in contrast to the optic disc, where endostatin expression was undetectable. Diabetic mice showed a reduction of endostatin in their retinas associated with the appearance of intravitreal vessels at the optic disc in 50% of db/db mice. Intravitreal vessels showed GFAP positive neuroglia sheath, basement membrane thickening by collagen IV deposition, and presence of MMP-2 and MMP-9 in the vascular wall. All together, these results point that decreased retinal endostatin during experimental diabetes is associated with optic disc intravitreal vascularization. Based on their phenotype, these intravitreal vessels could be neovessels. However, it cannot be ruled out the possibility that they may also represent persistent hyaloid vessels.info:eu-repo/semantics/publishedVersio

    Measuring direct and indirect tendon parameters to characterize the proximal tendinous complex of the rectus femoris in football and futsal players.

    Get PDF
    Objective: To present unprecedented radiological parameters that characterize the angle between the direct and indirect tendons of the proximal rectus femoris (RF) and its inclinations and to evaluate the population variability according to demographic variables. Materials and methods: From September 2019 to July 2021, using MRI multiplanar reconstructions of the proximal thigh/hip, two blinded radiologists measured the direct and indirect tendon angle and the inclination of each tendon in different planes. The intra- and inter-observer agreements were assessed with Bland–Altman analysis and intraclass correlation coefficient (ICC). The correlations between radiological parameters and demographic variables were evaluated using linear regression, Student’s t-test, and analysis of variance. Results: We performed 112 thigh/hip MRI scans on 91 football players of different age, gender, and disciplines (football and futsal). For observer 1 (the reference), the mean direct and indirect tendon angle was 56.74° ± 9.37, the mean indirect tendon slope was -7.90° ± 7.49, and the mean direct tendon slope was 22.16° ± 5.88. The three measurements showed inter- and intra-observer agreement (mean differences ~0). No correlation was observed between age and the parameters. Likewise, no statistically significant differences were found for gender, dominant limb, examined limb, and sport. Conclusion: There is an inter- and intra-observer agreement in the measurements of the direct and indirect tendon angle and the inclination of each tendon. There is population variability in the proximal tendinous complex unrelated to demographic factors. These results allow further detection of morphological patterns that represent a risk factor for lesions in the RF in professional football and futsal players and other sports.Peer ReviewedPostprint (published version

    Comparison of three different minimally invasive intramedullary screw for proximal phalanx fractures: a biomechanical study

    Get PDF
    Falange proximal; Tornillo endomedular; BiomecánicaProximal phalanx; Intramedullary screw; BiomechanicsFalange proximal; Cargol endomedular; BiomecànicaAntecedentes y objetivo Las fracturas de falange proximal (FP) son las fracturas más frecuentes de la mano. En los últimos años, se ha descrito el uso de tornillos endomedulares sin cabeza (TESC) para las fracturas inestables transversas u oblicuas de la FP. A pesar de que tanto la técnica anterógrada como retrógrada con TESC han mostrado buenos resultados, no se ha publicado ningún estudio comparativo de su uso en fracturas de FP. Nuestro objetivo es determinar la estabilidad que se obtiene con el uso de TESC retrógrados y anterógrados en un modelo en cadáver de fractura transversa proximal de FP, a dos niveles diferentes. Material y métodos Realizamos un estudio biomecánico en 30 modelos de fractura de FP de cadáver fresco-congelado. La osteotomía se realizó a los 9 mm desde la articulación metacarpofalángica (MCF) en 15 especímenes, y a una distancia de 15 mm en los otros 15. A su vez, en cada grupo, cinco osteotomías se estabilizaron con un TESC anterógrado intraarticular, cinco mediante un TESC anterógrado transarticular y cinco con un TESC retrógrado. Resultados La fijación con TESC anterógrado en osteotomías realizadas a los 9 mm (tanto con la técnica transarticular como intraarticular, 62,74 N y 70,86 N, respectivamente) fue más estable que la fijación con TESC retrógrado (32,72 N) (p 0,022). Por otra parte, la fijación con TESC retrógrado fue más estable en el modelo de fractura más distal (90,52 N retrógrado vs. 57,64 N transarticular vs. 42,92 N intraarticular (p = 0,20). Conclusiones La fijación con TESC retrógrado ofrece más estabilidad en fracturas más distales, mientras que las técnicas anterógradas son más estables en fracturas proximales.Background and objective Phalangeal fractures are the most common hand fractures. In the last years, intramedullary compression screw (IMHCS) for instable transverse or short oblique proximal P1 fractures have been described. Although both anterograde (intraarticular or trans-articular) and retrograde IMHCS techniques have shown good results, no comparison between anterograde and retrograde screw in P1 fractures has been published. We sought to determine stability with retrograde IMHCS and anterograde IMHCS, both trans-articular and intra-articular technique, in a cadaveric transverse proximal P1 fracture model, at two different levels. Material and methods We performed a biomechanical study in 30 fresh-frozen human cadaveric P1 fracture model. Fracture was performed at 9-mm from the metacarpo-phalangeal (MCP) joint in 15 specimens, whereas it was done at 15 mm in the other 15. In turn, in each group, five fractures were stabilized with an anterograde intra-articular IMHCS, five with anterograde trans-articular IMHCS and other five with retrograde IMHCS. Results Anterograde IMHCS fixation in 9-mm P1 fractures (both trans- and intra-articular technique, 62.74 N and 70.86 N, respectively) was found to be more stable than retrograde IMHCS one (32.72 N) (p = 0.022). Otherwise, retrograde IMHCS fixation was found to be more stable in more distal P1 fractures (90.52 N retrograde vs. 57.64 N trans-articular vs. 42.92 N intra-articular; p = 0.20). Conclusions Anterograde IMHCS fixation in proximal transverse P1 bone cut in a cadaveric model provides more stability than retrograde IMHCS, while retrograde screw provides more stability when the bone cut is located more distal.El presente trabajo ha sido financiado por la Sociedad Española de Cirugía Ortopédica y Traumatología: Proyectos de Iniciación a la Investigación Fundación SECOT
    corecore