65 research outputs found

    Towards ultrahigh throughput microinjection: MEMS-based massively-parallelized mechanoporation

    Get PDF
    We describe a massively-parallelized, MEMS-based device concept for passively delivering exogeneous molecules into living cells via mechanical membrane penetration, i.e., mechanoporation. Details regarding device design and fabrication are discussed, as are results from preliminary live cell studies focused on device validation at the proof-of-concept level. These efforts represent key steps towards our long-term goal of developing instrumentation capable of ultrahigh throughput (UHT) cellular manipulation via active microinjection

    Massively-Parallelized, Deterministic Mechanoporation for Intracellular Delivery

    Get PDF
    Microfluidic intracellular delivery approaches based on plasma membrane poration have shown promise for addressing the limitations of conventional cellular engineering techniques in a wide range of applications in biology and medicine. However, the inherent stochasticity of the poration process in many of these approaches often results in a trade-off between delivery efficiency and cellular viability, thus potentially limiting their utility. Herein, we present a novel microfluidic device concept that mitigates this trade-off by providing opportunity for deterministic mechanoporation (DMP) of cells en masse. This is achieved by the impingement of each cell upon a single needle-like penetrator during aspiration-based capture, followed by diffusive influx of exogenous cargo through the resulting membrane pore, once the cells are released by reversal of flow. Massive parallelization enables high throughput operation, while single-site poration allows for delivery of small and large-molecule cargos in difficult-to-transfect cells with efficiencies and viabilities that exceed both conventional and emerging transfection techniques. As such, DMP shows promise for advancing cellular engineering practice in general and engineered cell product manufacturing in particular

    A new multicompartmental reaction-diffusion modeling method links transient membrane attachment of E. coli MinE to E-ring formation

    Get PDF
    Many important cellular processes are regulated by reaction-diffusion (RD) of molecules that takes place both in the cytoplasm and on the membrane. To model and analyze such multicompartmental processes, we developed a lattice-based Monte Carlo method, Spatiocyte that supports RD in volume and surface compartments at single molecule resolution. Stochasticity in RD and the excluded volume effect brought by intracellular molecular crowding, both of which can significantly affect RD and thus, cellular processes, are also supported. We verified the method by comparing simulation results of diffusion, irreversible and reversible reactions with the predicted analytical and best available numerical solutions. Moreover, to directly compare the localization patterns of molecules in fluorescence microscopy images with simulation, we devised a visualization method that mimics the microphotography process by showing the trajectory of simulated molecules averaged according to the camera exposure time. In the rod-shaped bacterium _Escherichia coli_, the division site is suppressed at the cell poles by periodic pole-to-pole oscillations of the Min proteins (MinC, MinD and MinE) arising from carefully orchestrated RD in both cytoplasm and membrane compartments. Using Spatiocyte we could model and reproduce the _in vivo_ MinDE localization dynamics by accounting for the established properties of MinE. Our results suggest that the MinE ring, which is essential in preventing polar septation, is largely composed of MinE that is transiently attached to the membrane independently after recruited by MinD. Overall, Spatiocyte allows simulation and visualization of complex spatial and reaction-diffusion mediated cellular processes in volumes and surfaces. As we showed, it can potentially provide mechanistic insights otherwise difficult to obtain experimentally

    Transparent nanocrystalline yttria-stabilized-zirconia calvarium prosthesis

    Full text link
    UnlabelledLaser-based diagnostics and therapeutics show promise for many neurological disorders. However, the poor transparency of cranial bone (calvaria) limits the spatial resolution and interaction depth that can be achieved, thus constraining opportunity in this regard. Herein, we report preliminary results from efforts seeking to address this limitation through use of novel transparent cranial implants made from nanocrystalline yttria-stabilized zirconia (nc-YSZ). Using optical coherence tomography (OCT) imaging of underlying brain in an acute murine model, we show that signal strength is improved when imaging through nc-YSZ implants relative to native cranium. As such, this provides initial evidence supporting the feasibility of nc-YSZ as a transparent cranial implant material. Furthermore, it represents a crucial first step towards realization of an innovative new concept we are developing, which seeks to eventually provide a clinically-viable means for optically accessing the brain, on-demand, over large areas, and on a chronically-recurring basis, without need for repeated craniectomies.From the clinical editorIn this study, transparent nanocrystalline yttria-stabilized-zirconia is used as an experimental "cranium prosthesis" material, enabling the replacement of segments of cranial bone with a material that allows for optical access to the brain on a recurrent basis using optical imaging methods such as OCT

    Robust penetrating microelectrodes for neural interfaces realized by titanium micromachining

    Get PDF
    Neural prosthetic interfaces based upon penetrating microelectrode devices have broadened our understanding of the brain and have shown promise for restoring neurological functions lost to disease, stroke, or injury. However, the eventual viability of such devices for use in the treatment of neurological dysfunction may be ultimately constrained by the intrinsic brittleness of silicon, the material most commonly used for manufacture of penetrating microelectrodes. This brittleness creates predisposition for catastrophic fracture, which may adversely affect the reliability and safety of such devices, due to potential for fragmentation within the brain. Herein, we report the development of titanium-based penetrating microelectrodes that seek to address this potential future limitation. Titanium provides advantage relative to silicon due to its superior fracture toughness, which affords potential for creation of robust devices that are resistant to catastrophic failure. Realization of these devices is enabled by recently developed techniques which provide opportunity for fabrication of high-aspect-ratio micromechanical structures in bulk titanium substrates. Details are presented regarding the design, fabrication, mechanical testing, in vitro functional characterization, and preliminary in vivo testing of devices intended for acute recording in rat auditory cortex and thalamus, both independently and simultaneously

    Guidelines for chemotherapy of biliary tract and ampullary carcinomas

    Get PDF
    Few randomized controlled trials (RCTs) with large numbers of patients have been conducted to date in patients with biliary tract cancer, and standard chemotherapy has not been established yet. In this article we review previous studies and clinical trials regarding chemotherapy for unresectable biliary tract cancer, and we present guidelines for the appropriate use of chemotherapy in patients with biliary tract cancer. According to an RCT comparing chemotherapy and best supportive care for these patients, survival was significantly longer and quality of life was significantly better in the chemotherapy group than in the control group. Thus, chemotherapy for patients with biliary tract cancer seems to be a significant treatment of choice. However, chemotherapy for patients with biliary tract cancer should be indicated for those with unresectable, locally advanced disease or distant metastasis, or for those with recurrence after resection. That is why making the diagnosis of unresectable disease should be done with greatest care. As a rule, pathological diagnosis, including cytology or histopathological diagnosis, is preferable. Chemotherapy is recommended in patients with a good general condition, because in patients with general deterioration, such as those with a performance status of 2 or 3 or those with insufficient biliary decompression, the benefit of chemotherapy is limited. As chemotherapy for unresectable biliary tract cancer, the use of gemcitabine or tegafur/gimeracil/oteracil potassium is recommended. As postoperative adjuvant chemotherapy, no effective adjuvant therapy has been established at the present time. It is recommended that further clinical trials, especially large multi-institutional RCTs (phase III studies) using novel agents such as gemcitabine should be performed as soon as possible in order to establish a standard treatment
    corecore