15 research outputs found

    Low cost micro-Coulter counter with hydrodynamic focusing

    Get PDF

    Low cost micro-Coulter counter with hydrodynamic focusing

    No full text

    Low cost micro-Coulter counter with hydrodynamic focusing

    No full text

    Quantification of surface displacements and electromechanical phenomena via dynamic atomic force microscopy

    No full text
    Detection of dynamic surface displacements associated with local changes in material strain provides access to a number of phenomena and material properties. Contact resonance-enhanced methods of atomic force microscopy (AFM) have been shown capable of detecting similar to 1-3 pm-level surface displacements, an approach used in techniques such as piezoresponse force microscopy, atomic force acoustic microscopy, and ultrasonic force microscopy. Here, based on an analytical model of AFM cantilever vibrations, we demonstrate a guideline to quantify surface displacements with high accuracy by taking into account the cantilever shape at the first resonant contact mode, depending on the tip-sample contact stiffness. The approach has been experimentally verified and further developed for piezoresponse force microscopy (PFM) using well-defined ferroelectric materials. These results open up a way to accurate and precise measurements of surface displacement as well as piezoelectric constants at the pm-scale with nanometer spatial resolution and will allow avoiding erroneous data interpretations and measurement artifacts. This analysis is directly applicable to all cantilever-resonance-based scanning probe microscopy (SPM) techniques

    Nanobiosensors based on individual olfactory receptors

    No full text
    The animal olfactory system represents the gold standard of biosensors, due to its ability to identify and discriminate thousands of odorant compounds with very low thresholds. Using olfactory receptors (ORs) as sensing elements instead of chemical sensors, biosensors would benefit the naturally optimized molecular recognition of odorants to develop a new generation of bioelectronic noses. The purpose of SPOT-NOSED European project was the development of nanobiosensors based on single ORs anchored between nanoelectrodes, to mimic the performances of natural olfactory system. Nanobiosensors arrays could then increase odorant sensitivity or widen the odorant detection spectrum. ORs were expressed in yeasts plasmic membrane, and their functionality tested in whole yeasts. Then, nanosomes bearing the ORs were prepared from S. cerevisiae, and Surface Plasmon Resonance was performed on nanosomes for quantitative evaluation of OR response to odorant stimulation. ORs retain full activity and discrimination power in immobilized nanosomes, thus allowing their use in the fabrication of the nanobiosensors. Nanoelectrodes were fabricated using conventional photolithography and focused ion beam milling, with sizes in adequation with the nanosomes. ORs borne by nanosomes were specifically immobilized onto conducting substrates via mixed Self Assembled Monolayers, neutravidin and specific antibody to the ORs. The process was optimized by microcontact printing, and the anchored nanovesicles visualized by Atomic Force Microscopy. A transimpedance preamplifier suited for low-noise wide-bandwidth measurements was designed to be directly connected to the nanoelectrodes. Electrochemical Impedancemetric Spectroscopy detected significant changes upon electrodes functionalization, grafting of ORs carried by nanosomes, and ORs conformational change induced by odorant binding
    corecore