75 research outputs found

    Building performance evaluation and certification in the UK: a critical review of SAP?

    Get PDF
    Improving the efficiency and performance of the UK residential sector is now necessary for meeting future energy and climate change targets. Building Performance Evaluation and Certification (BPEC) tools are vital for estimating and recommending cost effective improvements to building energy efficiency and lowering overall emissions. In the UK, building performance is estimated using the Standard Assessment Procedure (SAP) for new dwellings and Reduced SAP (RdSAP) for existing dwellings. Using a systems based approach we show there are many opportunities for improving the effectiveness of BPEC tools. In particular, if the building stock is going to meet future energy and climate change targets the system driving building energy efficiency will need to become more efficient. In order to achieve this goal, building performance standards across Europe are compared highlighting the most effective strategies where they are found. It is shown that the large variance between estimated and actual energy performance from dwellings in the UK may be preventing the adoption of bottom-up energy efficiency measures. We show that despite popular belief, SAP and RdSAP do not estimate building energy efficiency but instead attempt to estimate the cost-effective performance of a building and thus create perverse incentives that may lead to additional CO2 emissions. In this regard, the SAP standard confounds cost-effectiveness, energy efficiency and environmental performance giving an inadequate estimate of all three policy objectives. Important contributions for improving measurement, analysis, synthesis and certification of building performance characteristics are offered.Efficienc

    A panel model for predicting the diversity of internal temperatures from English dwellings

    Get PDF
    Using panel methods, a model for predicting daily mean internal temperature demand across a heterogeneous domestic building stock is developed. The model offers an important link that connects building stock models to human behaviour. It represents the first time a panel model has been used to estimate the dynamics of internal temperature demand from the natural daily fluctuations of external temperature combined with important behavioural, socio-demographic and building efficiency variables. The model is able to predict internal temperatures across a heterogeneous building stock to within ~0.71°C at 95% confidence and explain 45% of the variance of internal temperature between dwellings. The model confirms hypothesis from sociology and psychology that habitual behaviours are important drivers of home energy consumption. In addition, the model offers the possibility to quantify take-back (direct rebound effect) owing to increased internal temperatures from the installation of energy efficiency measures. The presence of thermostats or thermostatic radiator valves (TRV) are shown to reduce average internal temperatures, however, the use of an automatic timer is statistically insignificant. The number of occupants, household income and occupant age are all important factors that explain a proportion of internal temperature demand. Households with children or retired occupants are shown to have higher average internal temperatures than households who do not. As expected, building typology, building age, roof insulation thickness, wall U-value and the proportion of double glazing all have positive and statistically significant effects on daily mean internal temperature. In summary, the model can be used as a tool to predict internal temperatures or for making statistical inferences. However, its primary contribution offers the ability to calibrate existing building stock models to account for behaviour and socio-demographic effects making it possible to back-out more accurate predictions of domestic energy demand

    National Principals\u27 Survey on Early Childhood Instructional Leadership

    Get PDF
    The National Association of Elementary School Principals (NAESP), the McCormick Center for Early Childhood Leadership at National Louis University, and New America partnered to study early childhood instructional leadership in schools. The National Principals’ Survey on Early Childhood Instructional Leadership was conducted in 2016 with the NAESP membership. This environmental scan collected basic descriptive data about the roles within schools and districts that contribute to instructional leadership and teacher supervision in preK classrooms. The survey was designed to examine the distribution of leadership functions; the influence of elementary principals on supporting children transitioning to kindergarten; classroom activities in preK and primary classrooms; and the alignment of curriculum, standards and instruction across the PreK-3 continuum

    Neoliberalism, managerialism and the reconfiguring of social work in Sweden and the United Kingdom

    Get PDF
    This is the author's manuscript of an article published in Archaeological Dialogues. http://dx.doi.org/10.1177/1350508412448222This paper considers some of the ways in which neoliberalism, through the processes of managerialism, has impacted on the occupation of social work in Sweden and the UK. It is argued that there are similar implications in both countries, through the managerial drive for increased performance in economy, efficiency and effectiveness, but also in the development of evidence based practice. Whilst the key focus of the paper is on similarities between these two countries, differences are also noted. There is also recognition of the way in which resistance to the reconfiguration of social work is taking shape

    Influence of socio-economic status on habitual physical activity and sedentary behavior in 8- to 11-year old children

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>While socio-economic status has been shown to be an important determinant of health and physical activity in adults, results for children and adolescents are less consistent. The purpose of this study, therefore, is to examine whether physical activity and sedentary behavior differs in children by socio-economic status (SES) independent of body mass index.</p> <p>Methods</p> <p>Data were from two cohorts including 271 children (117 males; 154 females) in study 1 and 131 children in study 2 (63 males; 68 females). The average age was 9.6 and 8.8 years respectively. Height and body mass were assessed according to standard procedures and body mass index (BMI, kg/m<sup>2</sup>) was calculated. Parent-reported household income was used to determine SES. Habitual, free-living physical activity (PA) was assessed by a pedometer (steps/day) in study 1 and accelerometer (time spent in moderate-to-vigorous PA) in study 2. Self-reported time spent watching TV and on the computer was used as measure of sedentary behavior. Differences in PA and sedentary behavior by SES were initially tested using ANOVA. Further analyses used ANCOVA controlling for BMI, as well as leg length in the pedometer cohort.</p> <p>Results</p> <p>In study 1, mean daily steps differed significantly among SES groups with lower SES groups approximating 10,500 steps/day compared to about 12,000 steps/day in the higher SES groups. These differences remained significant (p < 0.05) when controlling for leg length. Lower SES children, however, had higher body mass and BMI compared to higher SES groups (p < 0.05) and PA no longer remained significant when further controlling for BMI. In study 2 results depended on the methodology used to determine time spent in moderate-to-vigorous physical activity (MVPA). Only one equation resulted in significant group differences (p = 0.015), and these differences remained after controlling for BMI. Significant differences between SES groups were shown for sedentary behavior in both cohorts (P < 0.05) with higher SES groups spending less time watching TV than low SES groups.</p> <p>Conclusions</p> <p>Children from a low SES show a trend of lower PA levels and spend more time in sedentary behavior than high SES children; however, differences in PA were influenced by BMI. The higher BMI in these children might be another factor contributing to increased health risks among low SES children compared to children from with a higher SES.</p

    AMPK in Pathogens

    Get PDF
    During host–pathogen interactions, a complex web of events is crucial for the outcome of infection. Pathogen recognition triggers powerful cellular signaling events that is translated into the induction and maintenance of innate and adaptive host immunity against infection. In opposition, pathogens employ active mechanisms to manipulate host cell regulatory pathways toward their proliferation and survival. Among these, subversion of host cell energy metabolism by pathogens is currently recognized to play an important role in microbial growth and persistence. Extensive studies have documented the role of AMP-activated protein kinase (AMPK) signaling, a central cellular hub involved in the regulation of energy homeostasis, in host–pathogen interactions. Here, we highlight the most recent advances detailing how pathogens hijack cellular metabolism by suppressing or increasing the activity of the host energy sensor AMPK. We also address the role of lower eukaryote AMPK orthologues in the adaptive process to the host microenvironment and their contribution for pathogen survival, differentiation, and growth. Finally, we review the effects of pharmacological or genetic AMPK modulation on pathogen growth and persistence.CIHR -Canadian Institutes of Health Researc

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Predicting the diversity of internal temperatures from the English residential sector using panel methods

    Full text link
    In this paper, panel methods are applied in new and innovative ways to predict daily mean internal temperature demand across a heterogeneous domestic building stock over time. This research not only exploits a rich new dataset but presents new methodological insights and offers important linkages for connecting bottom-up building stock models to human behaviour. It represents the first time a panel model has been used to estimate the dynamics of internal temperature demand from the natural daily fluctuations of external temperature combined with important behavioural, socio-demographic and building efficiency variables. The model is able to predict internal temperatures across a heterogeneous building stock to within ∼0.71 °C at 95% confidence and explain 45% of the variance of internal temperature between dwellings. The model confirms hypothesis from sociology and psychology that habitual behaviours are important drivers of home energy consumption. In addition, the model offers the possibility to quantify take-back (direct rebound effect) owing to increased internal temperatures from the installation of energy efficiency measures. The presence of thermostats or thermostatic radiator valves (TRVs) are shown to reduce average internal temperatures, however, the use of an automatic timer is shown to be statistically insignificant. The number of occupants, household income and occupant age are all important factors that explain a quantifiable increase in internal temperature demand. Households with children or retired occupants are shown to have higher average internal temperatures than households who do not. As expected, building typology, building age, roof insulation thickness, wall U-value and the proportion of double glazing all have positive and statistically significant effects on daily mean internal temperature. In summary, the model can be either used to make statistical inferences about the importance of different factors for explaining internal temperatures or as a predictive tool. However, a key contribution of this research is the possibility to use this model to calibrate existing building stock for behaviour and socio-demographic effects leading to improved estimations of domestic energy demand. © 2012
    corecore