138 research outputs found

    A Time Series Analysis of Air Pollution and Preterm Birth in Pennsylvania, 1997–2001

    Get PDF
    Preterm delivery can lead to serious infant health outcomes, including death and lifelong disability. Small increases in preterm delivery risk in relation to spatial gradients of air pollution have been reported, but previous studies may have controlled inadequately for individual factors. Using a time-series analysis, which eliminates potential confounding by individual risk factors that do not change over short periods of time, we investigated the effect of ambient outdoor particulate matter with diameter ≤10 μm (PM(10)) and sulfur dioxide on risk for preterm delivery. Daily counts of preterm births were obtained from birth records in four Pennsylvania counties from 1997 through 2001. We observed increased risk for preterm delivery with exposure to average PM(10) and SO(2) in the 6 weeks before birth [respectively, relative risk (RR) = 1.07; 95% confidence interval (CI), 0.98–1.18 per 50 μg/m(3) increase; RR = 1.15; 95% CI, 1.00–1. 32 per 15 ppb increase], adjusting for long-term preterm delivery trends, co-pollutants, and offsetting by the number of gestations at risk. We also examined lags up to 7 days before the birth and found an acute effect of exposure to PM(10) 2 days and 5 days before birth (respectively, RR = 1.10; 95% CI, 1.00–1.21; RR = 1.07; 95% CI, 0.98–1.18) and SO(2) 3 days before birth (RR = 1.07; 95% CI, 0.99–1.15), adjusting for covariates, including temperature, dew point temperature, and day of the week. The results from this time-series analysis, which provides evidence of an increase in preterm birth risk with exposure to PM(10) and SO(2), are consistent with prior investigations of spatial contrasts

    Results from a Prototype Proton-CT Head Scanner

    Get PDF
    We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of treatment. Here we report on comprehensive beam test results with our prototype pCT head scanner. The detector system and data acquisition attain a sustained rate of more than a million protons individually measured per second, allowing a full CT scan to be completed in six minutes or less of beam time. In order to assess the performance of the scanner for proton radiography as well as computed tomography, we have performed numerous scans of phantoms at the Northwestern Medicine Chicago Proton Center including a custom phantom designed to assess the spatial resolution, a phantom to assess the measurement of relative stopping power, and a dosimetry phantom. Some images, performance, and dosimetry results from those phantom scans are presented together with a description of the instrument, the data acquisition system, and the calibration methods.Comment: Conference on the Application of Accelerators in Research and Industry, CAARI 2016, 30 October to 4 November 2016, Ft. Worth, TX, US

    Prediction of image noise contributions in proton computed tomography and comparison to measurements

    Get PDF
    We present a method to accurately predict image noise in proton computed tomography (pCT) using data generated from a Monte Carlo simulation and a patient or object model that may be generated from a prior x-ray CT image. This enables noise prediction for arbitrary beam fluence settings and, therefore, the application of fluence-modulated pCT (FMpCT), which can achieve prescribed noise targets and may significantly reduce the integral patient dose. We extended an existing Monte Carlo simulation of a prototype pCT scanner to include effects of quenching in the energy detector scintillators and constructed a beam model from experimental tracking data. Simulated noise predictions were compared to experimental data both in the projection domain and in the reconstructed image. Noise prediction agreement between simulated and experimental data in terms of the root-mean-square (RMS) error was better than 7% for a homogeneous water phantom and a sensitometry phantom with tubular inserts. For an anthropomorphic head phantom, modeling the anatomy of a five-year-old child, the RMS error was better than 9% in three evaluated slices. We were able to reproduce subtle noise features near heterogeneities. To demonstrate the feasibility of Monte Carlo simulated noise maps for fluence modulation, we calculated a fluence profile that yields a homogeneous noise level in the image. Unlike for bow-tie filters in x-ray CT this does not require constant fluence at the detector and the shape of the fluence profile is fundamentally different. Using an improved Monte Carlo simulation, we demonstrated the feasibility of using simulated data for accurate image noise prediction for pCT. We believe that the agreement with experimental data is sufficient to enable the future optimization of FMpCT fluence plans to achieve prescribed noise targets in a fluence-modulated acquisition

    Proton Therapy for Breast Cancer:A Consensus Statement From the Particle Therapy Cooperative Group Breast Cancer Subcommittee

    Get PDF
    Radiation therapy plays an important role in the multidisciplinary management of breast cancer. Recent years have seen improvements in breast cancer survival and a greater appreciation of potential long-term morbidity associated with the dose and volume of irradiated organs. Proton therapy reduces the dose to nontarget structures while optimizing target coverage. However, there remain additional financial costs associated with proton therapy, despite reductions over time, and studies have yet to demonstrate that protons improve upon the treatment outcomes achieved with photon radiation therapy. There remains considerable heterogeneity in proton patient selection and techniques, and the rapid technological advances in the field have the potential to affect evidence evaluation, given the long latency period for breast cancer radiation therapy recurrence and late effects. In this consensus statement, we assess the data available to the radiation oncology community of proton therapy for breast cancer, provide expert consensus recommendations on indications and technique, and highlight ongoing trials' cost-effectiveness analyses and key areas for future research. (c) 2021 Elsevier Inc. All rights reserved

    Efficacy and safety of telithromycin 800 mg once daily for 7 days in community-acquired pneumonia: an open-label, multicenter study

    Get PDF
    BACKGROUND: Community-acquired pneumonia (CAP) remains a major cause of morbidity and mortality throughout the world. Telithromycin (a new ketolide) has shown good in vitro activity against the key causative pathogens of CAP, including S pneumoniae resistant to penicillin and/or macrolides. METHODS: The efficacy and safety of telithromycin 800 mg orally once daily for 7 days in the treatment of CAP were assessed in an open-label, multicenter study of 442 adults. RESULTS: Of 149 microbiologically evaluable patients, 57 (9 bacteremic) had Streptococcus pneumoniae. Of the 57 S pneumoniae pathogens isolated in these patients, 9 (2 bacteremic) were penicillin- or erythromycin-resistant; all 57 were susceptible to telithromycin and were eradicated. Other pathogens and their eradication rates were: Haemophilus influenzae (96%), Moraxella catarrhalis (100%), Staphylococcus aureus (80%), and Legionella spp. (100%). The overall bacteriologic eradication rate was 91.9%. Of the 357 clinically evaluable patients, clinical cure was achieved in 332 (93%). In the 430 patients evaluable for safety, the most common drug-related adverse events were diarrhea (8.1%) and nausea (5.8%). CONCLUSION: Telithromycin 800 mg once daily for 7 days is an effective and well-tolerated oral monotherapy and offers a new treatment option for CAP patients, including those with resistant S pneumoniae

    Cerebral palsy and placental infection: a case-cohort study

    Get PDF
    BACKGROUND: The association between cerebral palsy in very preterm infants and clinical, histopathologic and microbiological indicators of chorioamnionitis, including the identification of specific micro-organisms in the placenta, was evaluated in a case-cohort study. METHODS: Children with a diagnosis of cerebral palsy at five years of age were identified from amongst participants in a long-term follow-up program of preterm infants. The comparison group was a subcohort of infants randomly selected from all infants enrolled in the program. The placentas were examined histopathologically for chorioamnionitis and funisitis, and the chorioamnionic interface was aseptically swabbed and comprehensively cultured for aerobic and anaerobic bacteria, yeast and genital mycoplasmas. Associations between obstetric and demographic variables, indicators of chorioamnionitis and cerebral palsy status were examined by univariate analysis. RESULTS: Eighty-two infants with cerebral palsy were compared with the subcohort of 207 infants. Threatened preterm labor was nearly twice as common among the cases as in the subcohort (p < 0.01). Recorded clinical choroamnionitis was similar in the two groups and there was no difference in histopathologic evidence of infection between the two groups. E. coli was cultured from the placenta in 6/30 (20%) of cases as compared with 4/85 (5%) of subcohort (p = 0.01). Group B Streptococcus was more frequent among the cases, but the difference was not statistically significant. CONCLUSIONS: The association between E. coli in the chorioamnion and cerebral palsy in preterm infants identified in this study requires confirmation in larger multicenter studies which include microbiological study of placentas
    corecore