Effect of temperature on the mechanical properties of X5CrNi18-9 steel
The results of static tensile tests conducted on a selected steel grade with austenitic matrix are discussed in this paper. The tensile tests were carried out at the following temperatures: 200°, 400° and 700 °C. Under the conditions of the static tensile test, all the samples failed with a characteristic “necking” forming a cup-conical shape. It has been found that with increasing temperature the strength properties decrease and the elongation increases. The microscopic examinations of the fractures showed that they were mostly plastic, and numerous “dimples” were filled with non-metallic inclusions characterized by a globular shape and a size of up to 8 µm
Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
J-PET is a detector optimized for registration of photons from the
electron-positron annihilation via plastic scintillators where photons interact
predominantly via Compton scattering. Registration of both primary and
scattered photons enables to determinate the linear polarization of the primary
photon on the event by event basis with a certain probability. Here we present
quantitative results on the feasibility of such polarization measurements of
photons from the decay of positronium with the J-PET and explore the physical
limitations for the resolution of the polarization determination of 511 keV
photons via Compton scattering. For scattering angles of about 82 deg (where
the best contrast for polarization measurement is theoretically predicted) we
find that the single event resolution for the determination of the polarization
is about 40 deg (predominantly due to properties of the Compton effect).
However, for samples larger than ten thousand events the J-PET is capable of
determining relative average polarization of these photons with the precision
of about few degrees. The obtained results open new perspectives for studies of
various physics phenomena such as quantum entanglement and tests of discrete
symmetries in decays of positronium and extend the energy range of polarization
measurements by five orders of magnitude beyond the optical wavelength regime.Comment: 10 pages, 14 figures, submitted to EPJ
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
A novel approach to tomographic data processing has been developed and
evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose
a system in which there is no need for powerful, local to the scanner
processing facility, capable to reconstruct images on the fly. Instead we
introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform
connected directly to data streams coming from the scanner, which can perform
event building, filtering, coincidence search and Region-Of-Response (ROR)
reconstruction by the programmable logic and visualization by the integrated
processors. The platform significantly reduces data volume converting raw data
to a list-mode representation, while generating visualization on the fly.Comment: IEEE Transactions on Medical Imaging, 17 May 201
J-PET: a new technology for the whole-body PET imaging
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built
from plastic scintillators. J-PET prototype consists of 192 detection modules
arranged axially in three layers forming a cylindrical diagnostic chamber with
the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial
arrangement of long strips of plastic scintillators, their small light
attenuation, superior timing properties, and relative ease of the increase of
the axial field-of-view opens promising perspectives for the cost effective
construction of the whole-body PET scanner, as well as construction of MR and
CT compatible PET inserts. Present status of the development of the J-PET
tomograph will be presented and discussed.Comment: Presented at the 2nd Jagiellonian Symposium on Fundamental and
Applied Subatomic Physics, Krak\'ow, Poland, June 4-9, 2017. To be published
in Acta Phys. Pol.
Three-dimensional image reconstruction in J-PET using Filtered Back Projection method
We present a method and preliminary results of the image reconstruction in
the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic
Emission), interactions of the 511 keV photons with a cylindrical detector were
generated. Pairs of such photons, flying back-to-back, originate from e+e-
annihilations inside a 1-mm spherical source. Spatial and temporal coordinates
of hits were smeared using experimental resolutions of the detector. We
incorporated the algorithm of the 3D Filtered Back Projection, implemented in
the STIR and TomoPy software packages, which differ in approximation methods.
Consistent results for the Point Spread Functions of ~5/7,mm and ~9/20, mm were
obtained, using STIR, for transverse and longitudinal directions, respectively,
with no time of flight information included.Comment: Presented at the 2nd Jagiellonian Symposium on Fundamental and
Applied Subatomic Physics, Krak\'ow, Poland, June 4-9, 2017. To be published
in Acta Phys. Pol.
Commissioning of the J-PET detector for studies of decays of positronium atoms
The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for
medical imaging of the whole human body as well as for physics studies
involving detection of electron-positron annihilation into photons. J-PET has
high angular and time resolution and allows for measurement of spin of the
positronium and the momenta and polarization vectors of annihilation quanta. In
this article, we present the potential of the J-PET system for background
rejection in the decays of positronium atoms.Comment: Presented at the 2nd Jagiellonian Symposium on Fundamental and
Applied Subatomic Physics, Krak\'ow, Poland, June 4-9, 2017. To be published
in Acta Phys. Pol.
Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
Recent tests of a single module of the Jagiellonian Positron Emission
Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips
have proven its applicability for the detection of annihilation quanta (0.511
MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved
resolution is almost by a factor of two better with respect to the current
TOF-PET detectors and it can still be improved since, as it is shown in this
article, the intrinsic limit of time resolution for the determination of time
of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much
lower. As the major point of the article, a method allowing to record
timestamps of several photons, at two ends of the scintillator strip, by means
of matrix of silicon photomultipliers (SiPM) is introduced. As a result of
simulations, conducted with the number of SiPM varying from 4 to 42, it is
shown that the improvement of timing resolution saturates with the growing
number of photomultipliers, and that the 2 x 5 configuration at two ends
allowing to read twenty timestamps, constitutes an optimal solution. The
conducted simulations accounted for the emission time distribution, photon
transport and absorption inside the scintillator, as well as quantum efficiency
and transit time spread of photosensors, and were checked based on the
experimental results. Application of the 2 x 5 matrix of SiPM allows for
achieving the coincidence resolving time in positron emission tomography of
0.170 ns for 15 cm axial field-of-view (AFOV) and 0.365 ns
for 100 cm AFOV. The results open perspectives for construction of a
cost-effective TOF-PET scanner with significantly better TOF resolution and
larger AFOV with respect to the current TOF-PET modalities.Comment: To be published in Phys. Med. Biol. (26 pages, 17 figures
Analysis procedure of the positronium lifetime spectra for the J-PET detector
Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful
tool to study the nanostructures of porous materials. Positron Emissions
Tomography (PET) are devices allowing imaging of metabolic processes e.g. in
human bodies. A newly developed device, the J-PET (Jagiellonian PET), will
allow PALS in addition to imaging, thus combining both analyses providing new
methods for physics and medicine. In this contribution we present a computer
program that is compatible with the J-PET software. We compare its performance
with the standard program LT 9.0 by using PALS data from hexane measurements at
different temperatures. Our program is based on an iterative procedure, and our
fits prove that it performs as good as LT 9.0.Comment: 4 figures, 8 page
Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph
J-PET is the first positron-emission tomograph (PET) constructed from plastic
scintillators. It was optimized for the detection of photons from
electron-positron annihilation. Such photons, having an energy of 511 keV,
interact with electrons in plastic scintillators predominantly via the Compton
effect. Compton scattering is at most probable at an angle orthogonal to the
electric field vector of the interacting photon. Thus registration of multiple
photon scatterings with J-PET enables to determine the polarization of the
annihilation photons. In this contribution we present estimates on the physical
limitation in the accuracy of the polarization determination of ~keV
photons with the J-PET detector.Comment: Submitted to Hyperfine Interaction
- …