176 research outputs found
Recent activity of the Be/X-ray binary system SAX J2103.5+4545
Aims. We present a multiwavelength study of the Be/X-ray binary system SAX
J2103.5+4545 with the goal of better characterizing the transient behaviour of
this source.
Methods. SAX J2103.5+4545 was observed by Swift-XRT four times in 2007 from
April 25 to May 5, and during quiescence in 2012 August 31. In addition, this
source has been monitored from the ground-based astronomical observatories of
El Teide (Tenerife, Spain), Roque de los Muchachos (La Palma, Spain) and Sierra
Nevada (Granada, Spain) since 2011 August, and from the TUBITAK National
Observatory (Antalya, Turkey) since 2009 June. We have performed spectral and
photometric temporal analyses in order to investigate the different states
exhibited by SAX J2103.5+4545.
Results. In X-rays, an absorbed power law model provided the best fit for all
the XRT spectra. An iron-line feature at ~6.42 keV was present in all the
observations except for that taken during quiescence in 2012. The photon
indexes are consistent with previous studies of SAX J2103.5+4545 in high/low
luminosity states. Pulsations were found in all the XRT data from 2007
(2.839(2) mHz; MJD 54222.02), but not during quiescence. Both optical outbursts
in 2010 and 2012 lasted for about 8/9 months (as the one in 2007 probably did
and the current one in 2014 might do) and were most probably caused by mass
ejection events from the Be star that eventually fed the circumstellar disc.
All of these outbursts started about 3 months before the triggering of the
X-ray activity, and about the same period before the maximum of the H_alpha
line equivalent width (in emission) was reached at only ~ -5 \AA. In this work
we found that the global correlation between the BV variability and the X-ray
intensity was also observed at longer wavelengths in the IR domain.Comment: 11 pages, 7 figures, and online material (2 tables). Submitted to A&A
in 2014 Januar
Detection of a large Be circumstellar disk during X-ray quiescence of XTE J1946+274
We present a multiwavelength study of the Be/X-ray binary system XTE
J1946+274 with the main goal of better characterizing its behavior during X-ray
quiescence. We aim to shed light on the mechanism which triggers the X-ray
activity for this source. XTE J1946+274 was observed by Chandra-ACIS during
quiescence in 2013 March 12. In addition, this source has been monitored from
the ground-based astronomical observatories of El Teide (Tenerife, Spain),
Roque de los Muchachos (La Palma, Spain) and Sierra Nevada (Granada, Spain)
since 2011 September, and from the TUBITAK National Observatory (Antalya,
Turkey) since 2005 April. We have performed spectral and photometric temporal
analyses in order to investigate the quiescent state and transient behavior of
this binary system. In 2006, a long mass ejection event took place from the Be
star, lasting for about seven years. We also found that a large Be
circumstellar disk was present during quiescence, although major X-ray activity
was not observed. We made an attempt to explain this scenario by assuming the
permanently presence of a tilted and warped Be circumstellar disk. The 0.3-10
keV X-ray spectrum during quiescence was well fitted with either an absorbed
blackbody or absorbed power-law models. The main parameters obtained for these
models were kT=1.43+/-0.17 and Gamma=0.9+/-0.4 (with N_H~2-7E+22 cm-2). The
0.3-10 keV flux of the source was ~0.8E-12 erg-1 cm-2 s-1. Pulsations were
found with P_pulse=15.757(1) s (MJD 56363.115) and an rms pulse fraction of
32.1(3)%. The observed X-ray luminosity during quiescent periods may be
explained by the neutron star being in supersonic propeller regimen.Comment: 9 pages, 7 figures, accepte
Neuroendocrine tumors presenting with thyroid gland metastasis: a case series
<p>Abstract</p> <p>Introduction</p> <p>Autopsy series have shown that metastasis to the thyroid gland has occurred in up to 24% of patients who have died of cancer. Neuroendocrine tumors may metastasize to thyroid gland.</p> <p>Case presentations</p> <p>Case 1 was a 17-year-old Turkish woman who was referred from our Endocrinology Department for a thyroidectomy for treatment of neuroendocrine tumor metastasis. She was treated with a bilateral total thyroidectomy. Histopathological examination results were consistent with a neuroendocrine tumor; neoplastic cells showed strong immunoreactivity to chromogranin A and synaptophysin, but the immunohistochemical profile was inconsistent with medullary thyroid carcinoma in that the tumor was negative for calcitonin, carcinoembryonic antigen, and thyroid transcription factor-1.</p> <p>Case 2 was a 54-year-old Turkish woman who presented with a 3-cm nodule on her right thyroid lobe. She had undergone surgery for a right lung mass four years previously. After a right pneumonectomy, thymectomy and lymph node dissection, a typical carcinoid tumor was diagnosed. Under ultrasonographic guidance, fine needle aspiration biopsy of her right thyroid pole nodule was performed and the biopsy was compatible with a neuroendocrine tumor metastasis. She was treated with a bilateral total thyroidectomy. Histopathological examination indicated three nodular lesions, 5 cm and 0.4 cm in diameter in her right lobe and 0.1 cm in diameter in her left lobe. The tumors were consistent with a neuroendocrine phenotype, showing strong immunoreactivity to chromogranin A and synaptophysin.</p> <p>Conclusion</p> <p>Thyroid nodules detected during follow-up of neuroendocrine tumor patients should be thoroughly investigated. A fine needle aspiration biopsy of the thyroid confirms the diagnosis in most cases and leads to appropriate management of those patients and may prevent unnecessary treatment approaches.</p
Pituitary and systemic autoimmunity in a case of intrasellar germinoma
Germinomas arising in the sella turcica are difficult to differentiate from autoimmune hypophysitis because of similar clinical and pathological features. This differentiation, nevertheless, is critical for patient care due to different treatments of the two diseases. We report the case of an 11-year-old girl who presented with diabetes insipidus and growth retardation, and was found to have an intra- and supra-sellar mass. Initial examination of the pituitary biopsy showed diffuse lymphocytic infiltration of the adenohypophysis and absent placental alkaline phosphatase expression, leading to a diagnosis of hypophysitis and glucocorticoid treatment. Because of the lack of clinical and radiological response, the pituitary specimen was re-examined, revealing this time the presence of scattered c-kit and Oct4 positive germinoma cells. The revised diagnosis prompted the initiation of radiotherapy, which induced disappearance of the pituitary mass. Immunological studies showed that the patient’s serum recognized antigens expressed by the patient’s own germinoma cells, as well as pituitary antigens like growth hormone and systemic antigens like the Sjögren syndrome antigen B and alpha-enolase. The study first reports the presence of pituitary and systemic antibodies in a patient with intrasellar germinoma, and reminds us that diffuse lymphocytic infiltration of the pituitary gland and pituitary antibodies does not always indicate a diagnosis of autoimmune hypophysitis
First results on the search for chameleons with the KWISP detector at CAST
We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of solar chameleons. The displacements are detected by a Michelson interferometer with a homodyne readout scheme. The sensor benefits from the focusing action of the ABRIXAS X-ray telescope installed at CAST, which increases the chameleon flux on the membrane. A mechanical chopper placed between the telescope output and the detector modulates the incoming chameleon stream. We present the results of the solar chameleon measurements taken at CAST in July 2017, setting an upper bound on the force acting on the membrane of 80pN at 95% confidence level. The detector is sensitive for direct
coupling to matter 104 = ßm = 108, where the coupling to photons is locally bound to ß¿ = 1011
In-depth investigation of the molecular pathogenesis of bladder cancer in a unique 26-year old patient with extensive multifocal disease: A case report
Background. The molecular characteristics and the clinical disease course of bladder cancer (BC) in young patients remain largely unresolved. All patients are monitored according to an intensive surveillance protocol and we aim to gain more insight into the molecular pathways of bladder tumors in young patients that could ultimately contribute to patient stratification, improve patient quality of life and reduce associated costs. We also determined whether a biomarker-based surveillance could be feasible. Case Presentation. We report a unique case of a 26-year-old Caucasian male with recurrent non-muscle invasive bladder tumors occurring at a high frequency and analyzed multiple tumors (maximal pTaG2) and urine samples of this patient. Analysis included FGFR3 mutation detection, FGFR3 and TP53 immunohistochemistry, mircosatellite analysis of markers on chromosomes 8, 9, 10, 11 and 17 and a genome wide single nucleotide polymorphism-array (SNP). All analyzed tumors contained a mutation in FGFR3 and were associated with FGFR3 overexpression. None of the tumors showed overexpression of TP53. We found a deletion on chromosome 9 in the primary tumor and this was confirmed by the SNP-array that showed regions of loss on chromosome 9. Detection of all recurrences was possible by urinary FGFR3 mutation analysis. Conclusions. Our findings would suggest that the BC disease course is determined by not only a patient's age, but also by the molecular characteristics of a tumor. This young patient contained typical genetic changes found in tumors of older patients and implies a clinical disease course comparable to older patients. We demonstrate that FGFR3 mutation analysis on voided urine is a simple non-invasive method and could serve as a feasible follow-up approach for this young patient presenting with an FGFR3 mutant tumor
Search for Dark Matter Axions with CAST-CAPP
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 μeV to 22.47 μeV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a strong dipole magnet, phase-matched to maximize the detection sensitivity. Here we report on the data acquired for 4124 h from 2019 to 2021. Each cavity is equipped with a fast frequency tuning mechanism of 10 MHz/ min between 4.774 GHz and 5.434 GHz. In the present work, we exclude axion-photon couplings for virialized galactic axions down to gaγγ = 8 × 10−14 GeV−1 at the 90% confidence level. The here implemented phase-matching technique also allows for future large-scale upgrades
First results of the CAST-RADES haloscope search for axions at 34.67 µeV
We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67 µeV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of ga¿ ¿ 4 × 10-13 GeV-1 over a mass range of 34.6738 µeV < ma< 34.6771 µeV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 µeV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities. © 2021, The Author(s)
- …