111 research outputs found

    What parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiography

    Get PDF
    BACKGROUND: Insufficient data describe the relationship of hemodynamic parameters to left ventricular (LV) diastolic flow propagation velocity (Vp) measured using color M-mode Doppler echocardiography. METHODS: An in vitro LV model used to simulate LV diastolic inflow with Vp measured under conditions of varying: 1) Stroke volume, 2) heart rate (HR), 3) LV volume, 4) LV compliance, and 5) transmitral flow (TMF) waveforms (Type 1: constant low diastasis flow and Type 2: no diastasis flow). RESULTS: Univariate analysis revealed excellent correlations of Vp with stroke volume (r = 0.98), LV compliance (r = 0.94), and HR with Type 1 TMF (r = 0.97). However, with Type 2 TMF, HR was not associated with Vp. LV volume was not related to Vp under low compliance, but inversely related to Vp under high compliance conditions (r = -0.56). CONCLUSION: These in vitro findings may help elucidate the relationship of hemodynamic parameters to early diastolic LV filling

    Effects of inosine on reperfusion injury after cardiopulmonary bypass

    Get PDF
    Objective: Inosine, a break-down product of adenosine has been recently shown to exert inodilatory and anti-inflammatory properties. Furthermore inosine might be a key substrate of pharmacological post-conditioning. In the present pre-clinical study, we investigated the effects of inosine on cardiac function during reperfusion in an experimental model of cardioplegic arrest and extracorporal circulation. Methods: Twelve anesthetized dogs underwent hypothermic cardiopulmonary bypass. After 60 minutes of hypothermic cardiac arrest, reperfusion was started after application of either saline vehicle (control, n = 6), or inosine (100 mg/kg, n = 6). Left ventricular end-systolic pressure volume relationship (ESPVR) was measured by a combined pressure-volume-conductance catheter at baseline and after 60 minutes of reperfusion. Left anterior descendent coronary blood flow (CBF), endothelium-dependent vasodilatation to acetylcholine (ACh) and endothelium-independent vasodilatation to sodium nitroprusside (SNP) were also determined. Results: The administration of inosine led to a significantly better recovery (given as percent of baseline) of ESPVR 90 ± 9% vs. 46 ± 6%, p &lt; 0.05. CBF and was also significantly higher in the inosine group (56 ± 8 vs. 23 ± 4, ml/min, p < 0.05). While the vasodilatatory response to SNP was similar in both groups, ACh resulted in a significantly higher increase in CBF (58 ± 6% vs. 25 ± 5%, p < 0.05) in the inosine group. Conclusions: Application of inosine improves myocardial and endothelial function after cardiopulmonary bypass with hypothermic cardiac arrest

    Wood biscuit measuring and sorting system

    Full text link
    V diplomskem delu je predstavljena izdelava naprave za dimenzijsko kontrolo lesenih veznih lamel. Opisana je avtomatska mehanska linija naprave, ki zajema zalogovnik, dvigalo, rotacijski vibracijski dodajalnik, merilno mesto ter sistem za ločevanje dobrih in slabih lamel. Osrednji del diplomskega dela predstavlja razvoj programske opreme v okolju Microsoft Visual Studio 2013. Programska oprema zajema krmiljenje vhodno-izhodnih signalov preko vzporednih vrat ter 32-kanalnega digitalnega vhodno-izhodnega modula, sistem programskih prekinitev za obdelavo slik v realnem času, funkcije za sledenje kosov in algoritem za iskanje povezanih komponent, funkcije meritev ter grafični uporabniški vmesnik.The aim of this thesis is to present the development of a wood biscuit measuring and sorting system. A description of an automatic mechanical line consisting of a reservoir, an elevator, a vibrating rotary supplier, a measuring system and a sorting system that separates perfect wood biscuits from imperfect ones is included. The core part of the thesis is a presentation of software development in Microsoft Visual Studio 2013. The developed software includes controlling input/output signals via a parallel port and a 32-channel digital input/output module, a system of software interruptions for real time picture processing, functions that allow tracing of individual items, an algorithm for connected-component labelling, measuring functions and a graphic user interface

    Rationale, design and methodology for Intraventricular Pressure Gradients Study: a novel approach for ventricular filling assessment in normal and falling hearts

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Intraventricular pressure gradients have been described between the base and the apex of the left ventricle during early diastolic ventricular filling, as well as, their increase after systolic and diastolic function improvement. Although, systolic gradients have also been observed, data are lacking on their magnitude and modulation during cardiac dysfunction. Furthermore, we know that segmental dysfunction interferes with the normal sequence of regional contraction and might be expected to alter the physiological intraventricular pressure gradients. The study hypothesis is that systolic and diastolic gradients, a marker of normal left ventricular function, may be related to physiological asynchrony between basal and apical myocardial segments and they can be attenuated, lost entirely, or even reversed when ventricular filling/emptying is impaired by regional acute ischemia or severe aortic stenosis.</p> <p>Methods/Design</p> <p><it>Animal Studies: </it>Six rabbits will be completely instrumented to measuring apex to outflow-tract pressure gradient and apical and basal myocardial segments lengthening changes at basal, afterloaded and ischemic conditions. Afterload increase will be performed by abruptly narrowing or occluding the ascending aorta during the diastole and myocardial ischemia will be induced by left coronary artery ligation, after the first diagonal branch.</p> <p><it>Patient Studies: </it>Patients between 65-80 years old (n = 12), both genders, with severe aortic stenosis referred for aortic valve replacement will be selected as eligible subjects. A high-fidelity pressure-volume catheter will be positioned through the ascending aorta across the aortic valve to measure apical and outflow-tract pressure before and after aortic valve replacement with a bioprosthesis. Peak and average intraventricular pressure gradients will be recorded as apical minus outflow-tract pressure and calculated during all diastolic and systolic phases of cardiac cycle.</p> <p>Discussion</p> <p>We expect to validate the application of our method to obtain intraventricular pressure gradients in animals and patients and to promote a methodology to better understand the ventricular relaxation and filling and their correlation with systolic function.</p

    Relevance of tissue Doppler in the quantification of stress echocardiography for the detection of myocardial ischemia in clinical practice

    Get PDF
    In the present article we review the main published data on the application of Tissue Doppler Imaging (TDI) to stress echocardiography for the detection of myocardial ischemia. TDI has been applied to stress echocardiography in order to overcome the limitations of visual analysis for myocardial ischemia. The introduction of a new technology for clinical routine use should pass through the different phases of scientific assessment from feasibility studies to large multicenter studies, from efficacy to effectiveness studies. Nonetheless the pro-technology bias plays a major role in medicine and expensive and sophisticated techniques are accepted before their real usefulness and incremental value to the available ones is assessed. Apparently, TDI is not exempted by this approach : its applications are not substantiated by strong and sound results. Nonetheless, conventional stress echocardiography for myocardial ischemia detection is heavily criticized on the basis of its subjectivity. Stress echocardiography has a long lasting history and the evidence collected over 20 years positioned it as an established tool for the detection and prognostication of coronary artery disease. The quantitative assessment of myocardial ischemia remains a scientific challenge and a clinical goal but time has not come for these newer ultrasonographic techniques which should be restricted to research laboratories

    CMR for Assessment of Diastolic Function

    Get PDF
    Prevalence of heart failure with preserved left ventricular ejection fraction amounts to 50% of all cases with heart failure. Diagnosis assessment requires evidence of left ventricular diastolic dysfunction. Currently, echocardiography is the method of choice for diastolic function testing in clinical practice. Various applications are in use and recommended criteria are followed for classifying the severity of dysfunction. Cardiovascular magnetic resonance (CMR) offers a variety of alternative applications for evaluation of diastolic function, some superior to echocardiography in accuracy and reproducibility, some being complementary. In this article, the role of the available CMR applications for diastolic function testing in clinical practice and research is reviewed and compared to echocardiography

    Speckle Tracking Echocardiography for the Assessment of the Athlete's Heart: Is It Ready for Daily Practice?

    Get PDF
    PURPOSE OF REVIEW: To describe the use of speckle tracking echocardiography (STE) in the biventricular assessment of athletes' heart (AH). Can STE aid differential diagnosis during pre-participation cardiac screening (PCS) of athletes? RECENT FINDINGS: Data from recent patient, population and athlete studies suggest potential discriminatory value of STE, alongside standard echocardiographic measurements, in the early detection of clinically relevant systolic dysfunction. STE can also contribute to subsequent prognosis and risk stratification. Despite some heterogeneity in STE data in athletes, left ventricular global longitudinal strain (GLS) and right ventricular longitudinal strain (RV ɛ) indices can add to differential diagnostic protocols in PCS. STE should be used in addition to standard echocardiographic tools and be conducted by an experienced operator with significant knowledge of the AH. Other indices, including left ventricular circumferential strain and twist, may provide insight, but further research in clinical and athletic populations is warranted. This review also raises the potential role for STE measures performed during exercise as well as in serial follow-up as a method to improve diagnostic yield

    Aerobic training protects cardiac function during advancing age: a meta-analysis of four decades of controlled studies

    Get PDF
    In contrast to younger athletes, there is comparatively less literature examining cardiac structure and function in older athletes. However, a progressive accumulation of studies during the past four decades offers a body of literature worthy of systematic scrutiny. We conducted a systematic review, meta-analysis and meta-regression of controlled echocardiography studies comparing left ventricular (LV) structure and function in aerobically trained older athletes (> 45 years) with age-matched untrained controls, in addition to investigating the influence of chronological age. statistic. , 95% CI 0.05-1.86, p = 0.04). Meta-regression for chronological age identified that athlete-control differences, in the main, are maintained during advancing age. Athletic older men have larger cardiac dimensions and enjoy more favourable cardiac function than healthy, non-athletic counterparts. Notably, the athlete groups maintain these effects during chronological ageing

    Pericardial and cardiac pressure.

    No full text
    corecore