28 research outputs found

    Thermal Control of a Dual Mode Parametric Sapphire Transducer

    Full text link
    We propose a method to control the thermal stability of a sapphire dielectric transducer made with two dielectric disks separated by a thin gap and resonating in the whispering gallery (WG) modes of the electromagnetic field. The simultaneous measurement of the frequencies of both a WGH mode and a WGE mode allows one to discriminate the frequency shifts due to gap variations from those due to temperature instability. A simple model, valid in quasi equilibrium conditions, describes the frequency shift of the two modes in terms of four tuning parameters. A procedure for the direct measurement of them is presented.Comment: 5 pages, 6 figures, presented at EFTF-IFCS joint conference 200

    Analysis of ring laser gyroscopes including laser dynamics

    Full text link
    Inertial sensors stimulate very large interest, not only for their application but also for fundamental physics tests. Ring laser gyros, which measure angular rotation rate, are certainly among the most sensitive inertial sensors, with excellent dynamic range and bandwidth. Large area ring laser gyros are routinely able to measure fractions of prad/s, with high duty cycle and bandwidth, providing fast, direct and local measurement of relevant geodetic and geophysical signals. Improvements of a factor 1010010-100 would open the windows for general relativity tests, as the GINGER project, an Earth based experiment aiming at the Lense-Thirring test at 1%1\% level. However, it is well known that the dynamics of the laser induces non-linearities, and those effects are more evident in small scale instruments. Sensitivity and accuracy improvements are always worthwhile, and in general there is demand for high sensitivity environmental study and development of inertial platforms, where small scale transportable instruments should be used. We discuss a novel technique to analyse the data, aiming at studying and removing those non-linearity. The analysis is applied to the two ring laser prototypes GP2 and GINGERINO, and angular rotation rate evaluated with the new and standard methods are compared. The improvement is evident, it shows that the back-scatter problem of the ring laser gyros is negligible with a proper analysis of the data, improving the performances of large scale ring laser gyros, but also indicating that small scale instruments with sensitivity of nrad/s are feasible.Comment: 9 pages and 7 figure

    Testing general relativity by means of ring lasers

    Get PDF
    The paper discusses the optimal conguration of one or more ring lasers to be used for measuring the general relativistic effects of the rotation of the Earth, as manifested on the surface of the planet. The analysis is focused on devices having their normal vector lying in the meridian plane. The crucial role of the evaluation of the angles is evidenced. Special attention is paid to the orientation at the maximum signal, minimizing the sensitivity to the orientation uncertainty. The use of rings at different latitudes is mentioned and the problem of the non-sphericity of the Earth is commented

    Testing general relativity by means of ring lasers

    Get PDF
    The paper discusses the optimal conguration of one or more ring lasers to be used for measuring the general relativistic effects of the rotation of the Earth, as manifested on the surface of the planet. The analysis is focused on devices having their normal vector lying in the meridian plane. The crucial role of the evaluation of the angles is evidenced. Special attention is paid to the orientation at the maximum signal, minimizing the sensitivity to the orientation uncertainty. The use of rings at different latitudes is mentioned and the problem of the non-sphericity of the Earth is commented

    Measuring the Virgo area tilt noise with a laser gyroscope

    Full text link
    We report on the measurements of tilt noise performed at the Virgo site with a ring laser gyroscope. The apparatus is a He-Ne laser operating in a square cavity mounted on a vertical plane perpendicular to the north-south arm of the inteferometer. We discuss the possibility of using the ring laser signal to improve the performances of the control system of the Virgo seismic suspensions. The comparison between the ring laser signal and the control signals for the longitudinal translations of the inverted pendulum (IP) shows remarkable coherence in the frequency range 20-200 mHz.Comment: 4 pages, Proceedings of 46th Rencontres de Morion

    Comparative analysis of local angular rotation between the Ring Laser Gyroscope GINGERINO and GNSS stations

    Full text link
    The study of local deformations is a hot topic in geodesy. Local rotations of the crust around the vertical axis can be caused by deformations. In the Gran Sasso area the ring laser prototype GINGERINO and the GNSS array are operative. One year of data of GINGERINO is compared with the ones from the GNSS stations, homogeneously selected around the position of GINGERINO, aiming at looking for rotational signals with period of days common to both systems. At that purpose the rotational component of the area circumscribed by the GNSS stations has been evaluated and compared with the GINGERINO data. The coherences between the signals show structures that even exceed 60%\% coherence over the 6-60 days period; to validate this unprecedented analysis two different methods have been used to evaluate the local rotation using the GNSS stations. The analysis reveals that the shared rotational signal's amplitude in both instruments is approximately 1013rad/s10^{-13} rad/s, an order of magnitude lower than the amplitudes of the signals examined using the coherence method. The ring laser array GINGER is at present under construction, and the confrontation of the ring laser data with GNSS antennas provides evidence of the fruibility and validity of the ring laser data for very low frequency investigation

    Three-axial Fiber Bragg Grating Strain Sensor for Volcano Monitoring

    Get PDF
    Fiber optic and FBGs sensors have attained a large diffusion in the last years as cost-effective monitoring and diagnostic devices in civil engineering. However, in spite of their potential impact, these instruments have found very limited application in geophysics. In order to study earthquakes and volcanoes, the measurement of crustal deformation is of crucial importance. Stress and strain behaviour is among the best indicators of changes in the activity of volcanoes .. Deep bore-hole dilatometers and strainmeters have been employed for volcano monitoring. These instruments are very sensitive and reliable, but are not cost-effective and their installation requires a large effort. Fiber optic based devices offer low cost, small size, wide frequency band, easier deployment and even the possibility of creating a local network with several sensors linked in an array. We present the realization, installation and first results of a shallow-borehole (8,5 meters depth) three-axial Fiber Bragg Grating (FBG) strain sensor prototype. This sensor has been developed in the framework of the MED-SUV project and installed on Etna volcano, in the facilities of the Serra La Nave astrophysical observatory. The installation siteis about 7 Km South-West of the summit craters, at an elevation of about 1740 m. The main goal of our work is the realization of a three-axial device having a high resolution and accuracy in static and dynamic strain measurements, with special attention to the trade-off among resolution, cost and power consumption. The sensor structure and its read-out system are innovative and offer practical advantages in comparison with traditional strain meters. Here we present data collected during the first five months of operation. In particular, the very clear signals recorded in the occurrence of the Central Italy seismic event of October 30th demonstrate the performances of our device.PublishedWien7TM. Sviluppo e Trasferimento Tecnologic

    Horizontal rotation signals detected by "G-Pisa" ring laser for the Mw=9.0, March 2011, Japan earthquake

    Get PDF
    We report the observation of the ground rotation induced by the Mw=9.0, 11th of March 2011, Japan earthquake. The rotation measurements have been conducted with a ring laser gyroscope operating in a vertical plane, thus detecting rotations around the horizontal axis. Comparison of ground rotations with vertical accelerations from a co-located force-balance accelerometer shows excellent ring laser coupling at periods longer than 100s. Under the plane wave assumption, we derive a theoretical relationship between horizontal rotation and vertical acceleration for Rayleigh waves. Due to the oblique mounting of the gyroscope with respect to the wave direction-of-arrival, apparent velocities derived from the acceleration / rotation rate ratio are expected to be always larger than, or equal to the true wave propagation velocity. This hypothesis is confirmed through comparison with fundamental-mode, Rayleigh wave phase velocities predicted for a standard Earth model.Comment: Accepted for publication in Journal of Seismolog

    Oncological cases and complications in Urology.

    Get PDF
    This collection of cases describes some unusual urological tumors and complications related to urological tumors and their treatment. Case 1: A case of left hydronephrosis referred four years after a right radical mastectomy for lobular breast carcinoma was described. Computed tomography scan revealed a left hydronephrosis with dilated ureter up to the proximal third. An exploratory laparoscopy was performed and the definitive histopathology examination showed a recurrence of the carcinoma with a right tubal metastasis and peritoneal carcinosis. Case 2: A rare case of an extensive penile squamous cell carcinoma in a young man. The patient was treated with radical surgery and modified inguinal lymphadenectomy. No recurrence was noticed so far. Case 3: A rare case of left sided Inferior Vena Cava (IVC) in a patient diagnosed with renal cell cancer who underwent open left partial nephrectomy. Case 4: A case of urethrorrhagia, caused by a recent trauma from an urinary catheter placed in a patient submitted to gastric resection due to a neoplastic pathology. Urethrorrhagia only temporarily responded to conservative treatment and ultimately resolved by coagulation with an endoscopic approach
    corecore