2,214 research outputs found

    Limits on Clouds and Hazes for the TRAPPIST-1 Planets

    Full text link
    The TRAPPIST-1 planetary system is an excellent candidate for study of the evolution and habitability of M-dwarf planets. Transmission spectroscopy observations performed with the Hubble Space Telescope (HST) suggest the innermost five planets do not possess clear hydrogen atmospheres. Here we reassess these conclusions with recently updated mass constraints and expand the analysis to include limits on metallicity, cloud top pressure, and the strength of haze scattering. We connect recent laboratory results of particle size and production rate for exoplanet hazes to a one-dimensional atmospheric model for TRAPPIST-1 transmission spectra. Doing so, we obtain a physically-based estimate of haze scattering cross sections. We find haze scattering cross sections on the order of 1e-26 to 1e-19 cm squared are needed in hydrogen-rich atmospheres for TRAPPIST-1 d, e, and f to match the HST data. For TRAPPIST-1 g, we cannot rule out a clear hydrogen-rich atmosphere. We also modeled the effects an opaque cloud deck and substantial heavy element content have on the transmission spectra. We determine that hydrogen-rich atmospheres with high altitude clouds, at pressures of 12mbar and lower, are consistent with the HST observations for TRAPPIST-1 d and e. For TRAPPIST-1 f and g, we cannot rule out clear hydrogen-rich cases to high confidence. We demonstrate that metallicities of at least 60xsolar with tropospheric (0.1 bar) clouds agree with observations. Additionally, we provide estimates of the precision necessary for future observations to disentangle degeneracies in cloud top pressure and metallicity. Our results suggest secondary, volatile-rich atmospheres for the outer TRAPPIST-1 planets d, e, and f.Comment: 15 pages, 3 figures, 2 tables, accepted in the Astronomical Journa

    Submaximal oxygen uptake efficiency slope as a predictor of VO2max in men with cardiovascular disease

    Get PDF
    Purpose: Although VĖ‡O2 max is considered the gold standard measure of cardiorespiratory fitness (CRF), it can be difficult to attain in patients with cardiovascular disease (CVD). The submaximal oxygen uptake efficiency slope (OUES) integrates cardiovascular, musculoskeletal and respiratory function during incremental exercise into a single index and has been proposed as an alternative and effort independent measure of cardiopulmonary reserve (Baba et al., 1996). The purpose of this study was to examine the relation between VĖ‡O2 max and both submaximal absolute OUES and relative OUES (OUES.kg-1). Methods: A total of 55 men ((mean Âą SD) age, 59.08 Âą 9.03 yr; VO2 max, 1.94 Âą 0.53 L.min-1and 22.73 Âą 5.95 mL.kg-1.min-1) were recruited during induction to a community based exercise referral program following completion of phase 2 cardiac rehabilitation. Participants performed a graded exercise test on a cycle ergometer with breath-by-breath open circuit spirometry and a 12 lead ECG. Absolute OUES and OUES.kg-1 were calculated by plotting VO2 in mL.min-1 on the x-axis, and the log transformed VE on the y-axis (VO2 = a log 10 VE + b). Exercise data up to the ventilatory anaerobic threshold (VAT) was included in the analysis. Results: The %VĖ‡O2 max corresponding to the VAT was 55.72 Âą 11.81. Absolute OUES and OUES.kg-1 were 2164.42 Âą 540.96 and 25.28 Âą 5.99, respectively. There was a significant positive correlation between VĖ‡O2 max (L.min-1) and OUES (r= 0.775; p<0.001) and between VĖ‡O2 max (mL.kg-1.min-1) and OUES.kg-1 (r= 0.78; p<0.001). Conclusion: Determination of VĖ‡O2 max is not often feasible in individuals with CVD where maximal exercise testing is contraindicated or when performance may be impaired by pain, dyspnea or angina. The findings from the present study indicate that the OUES and OUES.kg-1 are significantly related to absolute and relative VĖ‡O2 max, respectively and may be used as a valid sub maximal effort independent measure of CRF

    Relation between physical activity and oxygen uptake efficiency in men with CVD

    Get PDF
    Purpose: The oxygen uptake efficiency slope (OUES) represents the rate of increase in VĖ‡O2 in response to a given VĖ‡E during incremental exercise, indicating how effectively oxygen is taken in by the lungs, transported and used in the periphery. OUES, calculated using only submaximal exercise data is identical to the OUES calculated over the entire duration of a cardiopulmonary exercise test (CEPT) , and both maximal and submaximal OUE are significantly related to cardiorespiratory fitness (CRF) measured as VĖ‡O2peak. Currently, little research has been published on how physical activity (PA) assessed by accelerometers is related to submaximal and maximal OUES. The purpose of this study was to determine the relation light (LIPA), moderate (MIPA) and vigorous (VIPA) intensity physical activity and maximal and submaximal OUES in men with cardiovascular disease (CVD). Methods: A total of 56 men (mean ( SD): age of 59.3 Âą 9.2 yr., VĖ‡O2 peak (L/min) 2.0 0.50, VĖ‡O2 peak (mL/kg/min) 23.6 5.8, were recruited during an induction to a community-based exercise referral program following completion of phase 2 cardiac rehabilitation program. Participants underwent a graded exercise test on a cycle ergometer with breath by breath open circuit spirometry after which they wore a wrist worn accelerometer (Actigraph) for 7 d. Absolute and relative submaximal and maximal OUES were calculated by plotting VĖ‡O2 in mL/min on the x axis, and the log transformed VE on the y axis (VĖ‡O2 = a log 10 VE + b). Exercise data up to the ventilatory anaerobic threshold and maximal exercise were used to calculate submaximal and maximal OUE, respectively. Results: Participants performed 584.49 73.87 min of daily LIPA, 145.45 60.85 min of MIPA and no daily min of VIPA. There was a significant relation between absolute submaximal OUES (r=0.386; p<0.01), submaximal OUES/Kg (r=0.296; p<0.05) and LIPA. There was a significant relation between maximal OUES (r=0.286; p<0.05), maximal OUES/Kg (r=0.279; p<0.05) and MIPA. Conclusion: Submaximal and maximal OUE are related to levels of LIPA and MIPA, respectively. Submaximal OUES can potentially be used as an objective, effort independent test to estimate LIPA levels among men with CVD

    Physical activity patterns and cardiorespiratory fitness in men with cardiovascular disease

    Get PDF
    Purpose: Cardiorespiratory fitness (CRF) is generally regarded as an objective and reproducible measure of recent habitual physical activity (PA). Considering that the majority of daily PA is performed at light intensity, it is likely that CRF benefits will be detected at submaximal rather than maximal exercise. The purpose of this study was to evaluate daily minutes of light (LIPA), moderate (MIPA) and vigorous (VIPA) intensity physical activity among men with cardiovascular disease (CVD), and to determine the relation between PA and submaximal (oxygen uptake efficiency slope (OUES)) and maximal (VĖ‡O2 peak) indices of CRF. Methods: A total 32 male participants (mean ( SD): age of 60.0 Âą 8.7 yr, VĖ‡O2 peak (L/min) 2.0 0.45, VĖ‡O2 peak (mL/kg/min) 23.3 5.7, were recruited during an induction to a community based exercise referral program following completion of phase 2 cardiac rehabilitation. Participants underwent a graded exercise test on a cycle ergometer with breath by breath open circuit spirometry after which they wore a wrist worn accelerometer (Actigraph) for 7 d. Absolute and relative submaximal OUES were calculated by plotting VĖ‡O2 in mL/min on the x axis, and the log transformed VE on the y axis (VĖ‡O2 = a log 10 VE + b). Exercise data up to the ventilatory anaerobic threshold was included in the analysis. Results: Participants performed 589.05 69.41 min of daily LIPA, 161.38 66.16 min of MIPA and no daily min of VIPA. There was no significant relation between peak VĖ‡O2 and either LIPA or MIPA. There was a significant correlation between submaximal OUES (r=0.44; p<0.01) and LIPA. The relation between submaximal OUES/kg and LIPA min almost reached statistical significance (r=0.33; p<0.07). There was no significant relation between MIPA and OUES or OUES/kg. Conclusion: Men with CVD spend the majority (78%) of their day performing LIPA. OUES, a submaximal measure of CRF was related LIPA whereas no relation was found between VĖ‡O2 peak and LIPA

    Cortisol patterns are associated with T cell activation in HIV.

    Get PDF
    ObjectiveThe level of T cell activation in untreated HIV disease is strongly and independently associated with risk of immunologic and clinical progression. The factors that influence the level of activation, however, are not fully defined. Since endogenous glucocorticoids are important in regulating inflammation, we sought to determine whether less optimal diurnal cortisol patterns are associated with greater T cell activation.MethodsWe studied 128 HIV-infected adults who were not on treatment and had a CD4(+) T cell count above 250 cells/Âĩl. We assessed T cell activation by CD38 expression using flow cytometry, and diurnal cortisol was assessed with salivary measurements.ResultsLower waking cortisol levels correlated with greater T cell immune activation, measured by CD38 mean fluorescent intensity, on CD4(+) T cells (r = -0.26, p = 0.006). Participants with lower waking cortisol also showed a trend toward greater activation on CD8(+) T cells (r = -0.17, p = 0.08). A greater diurnal decline in cortisol, usually considered a healthy pattern, correlated with less CD4(+) (r = 0.24, p = 0.018) and CD8(+) (r = 0.24, p = 0.017) activation.ConclusionsThese data suggest that the hypothalamic-pituitary-adrenal (HPA) axis contributes to the regulation of T cell activation in HIV. This may represent an important pathway through which psychological states and the HPA axis influence progression of HIV

    Optical Properties of Organic Haze Analogues in Water-rich Exoplanet Atmospheres Observable with JWST

    Full text link
    JWST has begun its scientific mission, which includes the atmospheric characterization of transiting exoplanets. Some of the first exoplanets to be observed by JWST have equilibrium temperatures below 1000 K, which is a regime where photochemical hazes are expected to form. The optical properties of these hazes, which controls how they interact with light, are critical for interpreting exoplanet observations, but relevant experimental data are not available. Here we measure the density and optical properties of organic haze analogues generated in water-rich exoplanet atmosphere experiments. We report optical constants (0.4 to 28.6 {\mu}m) of organic haze analogues for current and future observational and modeling efforts covering the entire wavelength range of JWST instrumentation and a large part of Hubble. We use these optical constants to generate hazy model atmospheric spectra. The synthetic spectra show that differences in haze optical constants have a detectable effect on the spectra, impacting our interpretation of exoplanet observations. This study emphasizes the need to investigate the optical properties of hazes formed in different exoplanet atmospheres, and establishes a practical procedure to determine such properties.Comment: 4 figures, 1 Table, Published in Nature Astronom

    Intensified and protective CD4+ T cell immunity in mice with anti–dendritic cell HIV gag fusion antibody vaccine

    Get PDF
    Current human immunodeficiency virus (HIV) vaccine approaches emphasize prime boost strategies comprising multiple doses of DNA vaccine and recombinant viral vectors. We are developing a protein-based approach that directly harnesses principles for generating T cell immunity. Vaccine is delivered to maturing dendritic cells in lymphoid tissue by engineering protein antigen into an antibody to DEC-205, a receptor for antigen presentation. Here we characterize the CD4+ T cell immune response to HIV gag and compare efficacy with other vaccine strategies in a single dose. DEC-205–targeted HIV gag p24 or p41 induces stronger CD4+ T cell immunity relative to high doses of gag protein, HIV gag plasmid DNA, or recombinant adenovirus-gag. High frequencies of interferon (IFN)-Îģ– and interleukin 2–producing CD4+ T cells are elicited, including double cytokine-producing cells. In addition, the response is broad because the primed mice respond to an array of peptides in different major histocompatibility complex haplotypes. Long-lived T cell memory is observed. After subcutaneous vaccination, CD4+ and IFN-Îģ–dependent protection develops to a challenge with recombinant vaccinia-gag virus at a mucosal surface, the airway. We suggest that a DEC-targeted vaccine, in part because of an unusually strong and protective CD4+ T cell response, will improve vaccine efficacy as a stand-alone approach or with other modalities
    • â€Ķ
    corecore