51 research outputs found

    Developing Disposable EEG Cap for Infant Recordings at the Neonatal Intensive Care Unit

    Get PDF
    Long-term EEG monitoring in neonatal intensive care units (NICU) is challenged with finding solutions for setting up and maintaining a sufficient recording quality with limited technical experience. The current study evaluates different solutions for the skin–electrode interface and develops a disposable EEG cap for newborn infants. Several alternative materials for the skin–electrode interface were compared to the conventional gel and paste: conductive textiles (textured and woven), conductive Velcro, sponge, super absorbent hydrogel (SAH), and hydro fiber sheets (HF). The comparisons included the assessment of dehydration and recordings of signal quality (skin interphase impedance and powerline (50 Hz) noise) for selected materials. The test recordings were performed using snap electrodes integrated into a forearm sleeve or a forehead band along with skin–electrode interfaces to mimic an EEG cap with the aim of long-term biosignal recording on unprepared skin. In the hydration test, conductive textiles and Velcro performed poorly. While the SAH and HF remained sufficiently hydrated for over 24 h in an incubator-mimicking environment, the sponge material was dehydrated during the first 12 h. Additionally, the SAH was found to have a fragile structure and was electrically prone to artifacts after 12 h. In the electrical impedance and recording comparisons of muscle activity, the results for thick-layer HF were comparable to the conventional gel on unprepared skin. Moreover, the mechanical instability measured by 1–2 Hz and 1–20 Hz normalized relative power spectrum density was comparable with clinical EEG recordings using subdermal electrodes. The results together suggest that thick-layer HF at the skin–electrode interface is an effective candidate for a preparation-free, long-term recording, with many advantages, such as long-lasting recording quality, easy use, and compatibility with sensitive infant skin contact. Keywords: aEEG; NICU; SAH; HFPeer reviewe

    Developing Disposable EEG Cap for Infant Recordings at the Neonatal Intensive Care Unit

    Get PDF
    Long-term EEG monitoring in neonatal intensive care units (NICU) is challenged with finding solutions for setting up and maintaining a sufficient recording quality with limited technical experience. The current study evaluates different solutions for the skin–electrode interface and develops a disposable EEG cap for newborn infants. Several alternative materials for the skin–electrode interface were compared to the conventional gel and paste: conductive textiles (textured and woven), conductive Velcro, sponge, super absorbent hydrogel (SAH), and hydro fiber sheets (HF). The comparisons included the assessment of dehydration and recordings of signal quality (skin interphase impedance and powerline (50 Hz) noise) for selected materials. The test recordings were performed using snap electrodes integrated into a forearm sleeve or a forehead band along with skin–electrode interfaces to mimic an EEG cap with the aim of long-term biosignal recording on unprepared skin. In the hydration test, conductive textiles and Velcro performed poorly. While the SAH and HF remained sufficiently hydrated for over 24 h in an incubator-mimicking environment, the sponge material was dehydrated during the first 12 h. Additionally, the SAH was found to have a fragile structure and was electrically prone to artifacts after 12 h. In the electrical impedance and recording comparisons of muscle activity, the results for thick-layer HF were comparable to the conventional gel on unprepared skin. Moreover, the mechanical instability measured by 1–2 Hz and 1–20 Hz normalized relative power spectrum density was comparable with clinical EEG recordings using subdermal electrodes. The results together suggest that thick-layer HF at the skin–electrode interface is an effective candidate for a preparation-free, long-term recording, with many advantages, such as long-lasting recording quality, easy use, and compatibility with sensitive infant skin contact. Keywords: aEEG; NICU; SAH; HFPeer reviewe

    A Bedside Method for Measuring Effects of a Sedative Drug on Cerebral Function in Newborn Infants

    Get PDF
    Background: Data on the cerebral effects of analgesic and sedative drugs are needed for the development of safe and effective treatments during neonatal intensive care. Electroencephalography (EEG) is an objective, but interpreter-dependent method for monitoring cortical activity. Quantitative computerized analyses might reveal EEG changes otherwise not detectable. Methods: EEG registrations were retrospectively collected from 21 infants (mean 38.7 gestational weeks; range 27–42) who received dexmedetomidine during neonatal care. The registrations were transformed into computational features and analyzed visually, and with two computational measures quantifying relative and absolute changes in power (range EEG; rEEG) and cortico-cortical synchrony (activation synchrony index; ASI), respectively. Results: The visual assessment did not reveal any drug effects. In rEEG analyses, a negative correlation was found between the baseline and the referential frontal (rho = 0.612, p = 0.006) and parietal (rho = −0.489, p = 0.035) derivations. The change in ASI was negatively correlated to baseline values in the interhemispheric (rho = −0.753; p = 0.001) and frontal comparisons (rho = −0.496; p = 0.038). Conclusion: Cerebral effects of dexmedetomidine as determined by EEG in newborn infants are related to cortical activity prior to DEX administration, indicating that higher brain activity levels (higher rEEG) during baseline links to a more pronounced reduction by DEX. The computational measurements indicate drug effects on both overall cortical activity and cortico-cortical communication. These effects were not evident in visual analysis

    Extremely preterm children and relationships of minor neurodevelopmental impairments at 6 years

    Get PDF
    Lastenneurologia, toimintaterapia, psykologiaExtremely preterm children and relationships of minor neurodevelopmental impairments at 6 years Ulla Niutanen 1 *, Piia Lönnberg 1, Elina Wolford 2 , Marjo MetsĂ€ranta 3† and Aulikki Lano 1† 1 Department of Child Neurology, New Children’s Hospital, Pediatric Research Center, University of Helsinki and Helsinki University Hospital, Helsinki, Finland, 2 Department of Psychology and Logopedics, University of Helsinki, Helsinki, Finland, 3 Department of Pediatrics, New Children’s Hospital, Pediatric Research Center, University of Helsinki and Helsinki University Hospital, Helsinki, Finland Aim: This study investigated minor impairments in neurological, sensorimotor, and neuropsychological functioning in extremely preterm-born (EPT) children compared to term-born children. The aim was to explore the most affected domains and to visualize their co-occurrences in relationship maps. Methods: A prospective cohort of 56 EPT children (35 boys) and 37 term- born controls (19 boys) were assessed at a median age of 6 years 7 months with Touwen Neurological Examination, Movement Assessment Battery for Children, 2nd edition (MABC-2), Sensory Integration and Praxis Test (SIPT), and a Developmental Neuropsychological Assessment, 2nd edition (NEPSY-II). Altogether 20 test domains were used to illustrate the frequency of impaired test performances with a bar chart profile and to construct relationship maps of co-occurring impairments. Results: The EPT children were more likely to perform inferiorly compared to the term-born controls across all assessments, with a wider variance and more co-occurring impairments. When aggregating all impaired test domains, 45% of the EPT children had more impaired domains than any term-born child (more than five domains, p < 0.001). Relationship maps showed that minor neurological dysfunction (MND), NEPSY-II design copying, and SIPT finger identification constituted the most prominent relationship of co-occurring impairments in both groups. However, it was ten times more likely in the EPT group. Another relationship of co-occurring MND, impairment in NEPSY-II design copying, and NEPSY-II imitation of hand positions was present in the EPT group only. Interpretation: Multiple minor impairments accumulate among EPT children at six years, suggesting that EPT children and their families may need support and timely multi-professional interventions throughout infancy and childhood. FrontiersPeer reviewe

    A Bedside Method for Measuring Effects of a Sedative Drug on Cerebral Function in Newborn Infants

    Get PDF
    Background: Data on the cerebral effects of analgesic and sedative drugs are needed for the development of safe and effective treatments during neonatal intensive care. Electroencephalography (EEG) is an objective, but interpreter-dependent method for monitoring cortical activity. Quantitative computerized analyses might reveal EEG changes otherwise not detectable. Methods: EEG registrations were retrospectively collected from 21 infants (mean 38.7 gestational weeks; range 27–42) who received dexmedetomidine during neonatal care. The registrations were transformed into computational features and analyzed visually, and with two computational measures quantifying relative and absolute changes in power (range EEG; rEEG) and cortico-cortical synchrony (activation synchrony index; ASI), respectively. Results: The visual assessment did not reveal any drug effects. In rEEG analyses, a negative correlation was found between the baseline and the referential frontal (rho = 0.612, p = 0.006) and parietal (rho = −0.489, p = 0.035) derivations. The change in ASI was negatively correlated to baseline values in the interhemispheric (rho = −0.753; p = 0.001) and frontal comparisons (rho = −0.496; p = 0.038). Conclusion: Cerebral effects of dexmedetomidine as determined by EEG in newborn infants are related to cortical activity prior to DEX administration, indicating that higher brain activity levels (higher rEEG) during baseline links to a more pronounced reduction by DEX. The computational measurements indicate drug effects on both overall cortical activity and cortico-cortical communication. These effects were not evident in visual analysis

    Profile of minor neurological findings after perinatal asphyxia

    Get PDF
    Aim To characterise the spectrum of findings in sequential neurological examinations, general movements (GM) assessment and magnetic resonance imaging (MRI) of infants with perinatal asphyxia. Methods The prospective cohort study of term infants with perinatal asphyxia treated at Helsinki University Hospital's neonatal units in 2016-2020 used Hammersmith Neonatal Neurological Examination (HNNE) and brain MRI at 2 weeks and Hammersmith Infant Neurological Examination (HINE) and GM assessment at 3 months of age. Results Analysis included 50 infants: 33 displaying perinatal asphyxia without hypoxic-ischaemic encephalopathy (HIE), seven with HIE1 and 10 with HIE2. Of the infants with atypical HNNE findings, 24/25 perinatal asphyxia without HIE cases, 5/6 HIE1 cases and all 10 HIE2 cases showed atypical findings in the HINE. The HINE identified atypical spontaneous movements significantly more often in infants with white matter T2 hyperintensity. Conclusion In this cohort, most infants with perinatal asphyxia, with or without HIE, presented atypical neurological findings in sequential examinations. The profile of neurological findings for children with perinatal asphyxia without HIE resembled that of children with HIE. White matter T2 hyperintensity was associated with atypical spontaneous movements in the HINE and was a frequent MRI finding also in perinatal asphyxia without HIE.Peer reviewe

    A case of congenital tuberculosis with a favorable outcome in a full term neonate

    Get PDF
    This case of congenital tuberculosis (TB) emphasizes that TB should be suspected in newborns whose parents are from areas with high incidence of TB or who present with symptoms of an infection unresponsive to wide-spectrum antibiotics.Peer reviewe

    Towards multimodal brain monitoring in asphyxiated newborns with amplitude-integrated EEG and simultaneous somatosensory evoked potentials

    Get PDF
    Background: Somatosensory evoked potentials (SEPs) offer an additional bedside tool for outcome prediction after perinatal asphyxia. Aims: To assess the reliability of SEPs recorded with bifrontoparietal amplitude-integrated electroencephalography (aEEG) brain monitoring setup for outcome prediction in asphyxiated newborns undergoing therapeutic hypothermia. Study design: Retrospective observational single-center study. Subjects: 27 consecutive asphyxiated fullor near-term newborns (25 under hypothermia) that underwent median nerve aEEG-SEPs as part of their clinical evaluation at the neonatal intensive care unit of Helsinki University Hospital. Outcome measures: aEEG-SEP classification (present, absent or unreliable) was compared to classification of SEPs recorded with a full EEG montage (EEG-SEP), and outcome determined from medical records at approximately 12-months-age. Unfavorable outcome included death, cerebral palsy, or severe epilepsy. Results: The aEEG-SEP and EEG-SEP classifications were concordant in 21 of the 22 newborns with both recordings available. All five newborns with bilaterally absent aEEG-SEPs had absent EEG-SEPs and the four with outcome information available had an unfavorable outcome (one was lost to follow-up). Of the newborns with aEEG-SEPs present, all with follow-up exams available had bilaterally present EEG-SEPs and a favorable outcome (one was lost to follow-up). One newborn with unilaterally absent aEEG-SEP at 25 h of age had bilaterally present EEG-SEPs on the next day, and a favorable outcome. Conclusions: aEEG-SEPs recorded during therapeutic hypothermia on the first postnatal days are reliable for assessing brain injury severity. Adding SEP into routine aEEG brain monitoring offers an additional tool for very early outcome prediction after birth asphyxia.Peer reviewe
    • 

    corecore