837 research outputs found
Recommended from our members
Measurement of post-lens tear thickness.
PURPOSE: A method to measure the tear film beneath a soft contact lens, referred to as post-lens tear thickness (PLTT), would have many applications to contact lens research. In this study a noninvasive technique for measuring the PLTT is presented. METHODS: The feasibility of measuring the tear layer by optical pachometry was first assessed using a model eye. The baseline corneal thickness (B) of both eyes of 21 subjects was measured, etafilcon-A ionic disposable soft contact lenses (58% water) were inserted, and the total thickness (T) of the cornea, contact lens, and PLTT were measured. After the pachometry readings the lenses were removed and their center thickness (C) determined. The PLTT was calculated using the equation: PLTT = T-(B+C). Two sets of measurements of T were performed at 15 and 25 minutes after lens insertion. The entire procedure was repeated at a second visit. RESULTS: The pachometry measurements of the small aqueous reservoir between the model eye and the lens closely matched those obtained by direct microscopic measurement. For human PLTT, the mean values (and 95% confidence intervals) for right eyes on visits 1 and 2 were 11 (8, 13) and 12 (10, 15) microm, respectively, and for left eyes were 12 (10, 15) and 11 microm (8, 14) microm, respectively. CONCLUSIONS: It is possible to measure the post-lens tear thickness using optical pachometry. The variability between repeated measurements suggests that with careful sample size planning, the technique is sufficiently precise to be useful in group assessments of PLTT
Recommended from our members
The Berkeley Contact Lens Extended Wear Study. Part I : Study design and conduct.
ObjectiveThe primary aim of the Berkeley Contact Lens Extended Wear Study (CLEWS) was to test the hypotheses that extended wear of rigid gas-permeable (RGP) contact lenses with greater oxygen permeability (Dk) reduces the incidence of contact lens-associated keratopathy (CLAK) and increases the survival rate in RGP extended wear (EW). In this article we describe the clinical trial design in detail, present the results of subject recruitment and retention, and provide the baseline demographic and ocular characteristics of the CLEWS subjects, whose data will be analyzed to address the study aims in a companion article.DesignA randomized, concurrently controlled clinical trial.InterventionSubjects were fitted with day wear (DW) high-Dk RGP lenses and then adapted to EW. Subjects who adapted to EW were then randomly assigned to either high- or medium-Dk RGP lenses for 12 months of 6-nights/week EW.Main outcome measuresSlit-lamp assessment and grading of 17 possible keratopathies, measurement of refractive error and corneal curvature, and symptoms. Follow-up data were collected every 3 months.ResultsFrom 545 subjects entering the DW adaptation phase, 201 adapted to EW and were randomly assigned to medium- or high-Dk lenses for 12 months of EW. The baseline characteristics of the two study groups were similar and did not differ from the 344 DW subjects who failed to adapt to EW. The distributions of oxygen transmissibility for the two study groups were disjoint, indicating that each group received distinctly different levels of hypoxia.ConclusionsWe show that CLEWS was appropriately designed to address the study hypotheses, was conducted with regard for the safety of the subjects, and adhered to rigorous protocols designed to control for bias and ensure the integrity of study data. We establish the internal validity of between-group statistical comparisons and characterize our study population to permit informed evaluation of the applicability of our results to the contact lens-wearing population in general
The Berkeley Contact Lens Extended Wear Study. Part II : Clinical results.
ObjectiveTo describe the principal clinical outcomes associated with 12 months use of rigid gas-permeable (RGP) extended wear contact lenses and address two primary study questions: (1) does extended wear (EW) of high oxygen transmissibility (Dk/t) RGP lenses reduce the incidence of ocular complications, and (2) does the wearing of high-Dk/t lenses reduce the rate of failure to maintain 6-night RGPEW over 12 months?DesignA randomized, concurrently controlled clinical trial.InterventionSubjects who adapted to EW with high Dk (oxygen permeability) RGP lenses were randomized to either high Dk or medium-Dk RGP lenses for 12 months of 6-night EW.Main outcome measuresContact lens-associated keratopathies (CLAK), changes in refractive error and corneal curvature, and survival in EW.ResultsTwo hundred one subjects were randomized to medium or high-Dk lenses for 12 months of EW. Sixty-two percent of the subjects in each group completed 12 months of EW; however, the probability of failure was significantly greater for the medium-Dk group. Although the risk of complications was similar for the two groups, the number of CLAK events that led to termination were 16 versus 5 for the medium-Dk and high-Dk groups, respectively. This suggests that the type of adverse response or the inability to reverse an adverse event was different for the group being exposed to the lower oxygen dose.ConclusionsThe level of oxygen available to the cornea has a significant impact on maintaining successful RGP extended contact lens wear, but not on the initial onset of CLAK. The number of clinical events leading to termination was substantially higher for the medium Dk group, which suggests that corneal hypoxia is an important factor in the development of CLAK. Although overnight contact lens wear should be recommended with caution and carefully monitored for early detection of ocular complications, it appears that high-Dk RGP lenses can be a safe and effective treatment for correction of refractive error for most individuals who can adapt to EW
Recommended from our members
The effects of one-hour wear of high-Dk soft contact lenses on corneal pH and epithelial permeability.
PurposePrevious studies have shown that 1-hour closed-eye contact lens wear with a low-Dk lens causes a significant reduction in corneal pH and an increase in epithelial permeability. In the present study, we evaluated the effects of super-high-Dk/t soft lenses on corneal epithelial barrier function and stromal pH.MethodsCorneal thickness was measured by optical pachometry, while epithelial permeability and stromal pH were measured by fluorophotometry. A paired-eye design was used in which one eye was randomly allocated to wear a high-oxygen-permeable soft lens (CIBAVision Focus/NIGHT & DAY (Dk/t= 175) while the other eye did not wear a lens.ResultsAfter 1-hour closed-eye lens wear, neither the difference in corneal swelling (P = 0.206) nor the permeability (P = 0.055) between both eyes was significantly different. The mean pH values under open-eye conditions were 7.66 vs. 7.57 for the treatment and control eyes, respectively (P = 0.082), dropping to 7.27 vs. 7.25 after 1-hour eye closure (P = 0.283).ConclusionsAlthough our results are limited to a 1-hour observation period, they do provide evidence that high-Dk materials may eliminate corneal acidosis and reduced epithelial barrier function that accompany closed-eye contact lens wear with lower-Dk soft lens materials
A systematic review of intravenous gamma globulin for therapy of acute myocarditis
BACKGROUND: Intravenous gamma globulin (IVGG) is commonly used in the management of acute myocarditis. The objective of this study was to systematically review the literature evaluating this practice. METHODS: We conducted a comprehensive search (electronic databases, trials registries, conference proceedings, reference lists, contact with authors) to identify studies evaluating the use of IVGG in adults and children with a clinical or histologically proven diagnosis of myocarditis of possible viral etiology and symptoms of less than six months duration. Two reviewers independently screened the searches, applied inclusion criteria, and graded the evidence. RESULTS: Results were described qualitatively; data were not pooled because only one randomized controlled trial (RCT) with 62 patients was identified. The RCT showed no benefit with respect to cardiac function, functional outcome, or event-free survival. A small, uncontrolled trial (n = 10) showed significant improvement in LVEF from a mean of 24% to 41% 12 months after IVGG in nine survivors. A retrospective cohort study of pediatric patients showed improvement in cardiac function and a trend towards improved survival in patients receiving IVGG (n = 21) versus historic controls (n = 25). Ten case reports and two case series (total n = 21) described improvement in cardiac function after administration of IVGG; two case reports showed no benefit of IVGG. One case of hemolytic anemia was attributed to IVGG. CONCLUSION: There is insufficient data from methodologically strong studies to recommend routine use of IVGG for acute myocarditis. Future randomized studies that take into account the etiology of acute myocarditis will be required to determine the efficacy of IVGG
Fluorophotometry as a diagnostic tool for the evaluation of dry eye disease
BACKGROUND: Dry eye disease is a common debilitating ocular disease. Current diagnostic tests used in dry eye disease are often neither sensitive nor reproducible, making it difficult to accurately diagnose and determine end points for clinical trials, or evaluate the usefulness of different medications in the treatment of dry eye disease. The recently developed fluorophotometer can objectively detect changes in the corneal epithelium by quantitatively measuring its barrier function or permeability. The purpose of the study is to investigate the use of corneal fluorescein penetration measured by the fluorophotometer as a diagnostic tool in the evaluation of dry eye patients. METHODS: Dry eye patients (16 eyes), who presented with a chief complaint of ocular irritation corresponding with dry eye, low Schirmer's one test (<10 mm after 5 minutes) and corneal fluorescein staining score of more than two, were included in the study. Normal subjects (16 eyes), who came for refraction error evaluation, served as controls. Institutional Review Board (IRB) approved consent was obtained before enrolling the subjects in the study and all questions were answered while explaining the risks, benefits and alternatives. All Fluorophotometry of the central corneal epithelium was done utilizing the Fluorotron Master (TradeMark). Each eye had a baseline fluorescein scan performed, after which 50 l of 1% sodium fluorescein dye was instilled. Three minutes later, the fluorescein was washed with 50 ml of normal saline. Fluorescein scans were then started immediately after washing and were recorded at 10, 20, 40, and 60 minutes thereafter. The corneal peak values of fluorescein concentration were recorded within the central cornea in both dry eyes and in controls. RESULTS: Ten minutes after fluorescein installition, patients with dry eye disease averaged a five-fold increase in corneal tissue fluorescein concentration (mean = 375.26 ± 202.67 ng/ml) compared with that of normal subjects (mean = 128.19 ± 85.84 ng/ml). Sixty minutes after dye installation, patients with dry eye disease still revealed higher corneal tissue fluorescein concentration (mean = 112.87 ± 52.83 ng/ml) compared with that of controls (mean = 40.64 ± 7.96 ng/ml), averaging a three-fold increase. CONCLUSION: Patients with dry eye disease demonstrated an increased corneal permeability and a slower rate of elimination to topically administered fluorescein when measured by the fluorophotometer. This suggests that fluorophotometry may serve as a valuable quantitative and objective tool for the diagnosis of dry eye disease, and in following patients' response to new treatment modalities. Fluorophotometry may serve as an objective non-invasive tool for end-point analysis in clinical trials of new treatments for dry eye disease
Lattice Boltzmann simulations of soft matter systems
This article concerns numerical simulations of the dynamics of particles
immersed in a continuum solvent. As prototypical systems, we consider colloidal
dispersions of spherical particles and solutions of uncharged polymers. After a
brief explanation of the concept of hydrodynamic interactions, we give a
general overview over the various simulation methods that have been developed
to cope with the resulting computational problems. We then focus on the
approach we have developed, which couples a system of particles to a lattice
Boltzmann model representing the solvent degrees of freedom. The standard D3Q19
lattice Boltzmann model is derived and explained in depth, followed by a
detailed discussion of complementary methods for the coupling of solvent and
solute. Colloidal dispersions are best described in terms of extended particles
with appropriate boundary conditions at the surfaces, while particles with
internal degrees of freedom are easier to simulate as an arrangement of mass
points with frictional coupling to the solvent. In both cases, particular care
has been taken to simulate thermal fluctuations in a consistent way. The
usefulness of this methodology is illustrated by studies from our own research,
where the dynamics of colloidal and polymeric systems has been investigated in
both equilibrium and nonequilibrium situations.Comment: Review article, submitted to Advances in Polymer Science. 16 figures,
76 page
Effects of X-ray dose on rhizosphere studies using X-ray computed tomography
X-ray Computed Tomography (CT) is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix of mineral grains, organic matter, air-filled pores and water-filled pores. Additionally, X-ray CT allows visualisation of plant roots in situ without the need for traditional invasive methods such as root washing. However, one routinely unreported aspect of X-ray CT is the potential effect of X-ray dose on the soil-borne microorganisms and plants in rhizosphere investigations. Here we aimed to i) highlight the need for more consistent reporting of X-ray CT parameters for dose to sample, ii) to provide an overview of previously reported impacts of X-rays on soil microorganisms and plant roots and iii) present new data investigating the response of plant roots and microbial communities to X-ray exposure. Fewer than 5% of the 126 publications included in the literature review contained sufficient information to calculate dose and only 2.4% of the publications explicitly state an estimate of dose received by each sample. We conducted a study involving rice roots growing in soil, observing no significant difference between the numbers of root tips, root volume and total root length in scanned versus unscanned samples. In parallel, a soil microbe experiment scanning samples over a total of 24 weeks observed no significant difference between the scanned and unscanned microbial biomass values. We conclude from the literature review and our own experiments that X-ray CT does not impact plant growth or soil microbial populations when employing a low level of dose (<30 Gy). However, the call for higher throughput X-ray CT means that doses that biological samples receive are likely to increase and thus should be closely monitored
A General RNA Motif for Cellular Transfection
We have developed a selection scheme to generate nucleic acid sequences that recognize and directly internalize into mammalian cells without the aid of conventional delivery methods. To demonstrate the generality of the technology, two independent selections with different starting pools were performed against distinct target cells. Each selection yielded a single highly functional sequence, both of which folded into a common core structure. This internalization signal can be adapted for use as a general purpose reagent for transfection into a wide variety of cell types including primary cells
- …