8 research outputs found
Standardization of pattern electroretinograms by alternate reversion in normal volunteers
PURPOSE: To standardize recordings of pattern electroretinograms (PERG) in normal human subjects. METHODS: The standardization followed the model proposed by the International Organization of Eletroretinography and was specific for the laboratory of evoked potentials of the Department of Neurology, Faculty of Medical Sciences, State University of Campinas. Two types of stimuli were used, one of 30 minutes of arch of visual angle and another of 60 minutes of arch of visual angle. RESULTS: In all patients a positive wave, defined internationally as P50, and a negative, called N95, were obtained without interferences. The normal range for latency, amplitude and duration of each wave was obtained. There were significative differences in amplitude, latency and duration of P50 and N95 waves among the several age groups. There was an increase in latency and a decrease in amplitude with increasing age. No significative differences were found among the variables comparing different stimuli, sex or when eyes were compared with each other. CONCLUSIONS: The standardization of pattern electroretinograms yield reproductibility of results and the possibility of further comparative studies.OBJETIVO: Realizar a normatização do eletrorretinograma por reversão alternada em indivÃduos oftalmologicamente normais e sem doenças neurológicas associadas, determinando a faixa de normalidade estratificada por sexo, faixa etária e estÃmulo utilizado. MÉTODOS: A padronização seguiu o modelo proposto pela Organização Internacional de Eletrorretinografia e a normatização foi especÃfica para o laboratório de potenciais evocados do Departamento de Neurologia da Faculdade de Ciências Médicas - Universidade Estadual de Campinas. Dois tipos de estÃmulos foram utilizados: o denominado estÃmulo 16, que proporciona ângulo visual de 60 minutos de arco e o de 32, que proporciona ângulo visual de 30. RESULTADOS: Em todos os pacientes obteve-se uma onda positiva, definida internacionalmente como P50 e uma negativa, chamada N95, sem a presença de artefatos. Foram observados intervalos de normalidade que continham a média das latências, amplitudes e durações das curvas positiva e negativa, internacionalmente aceitas. As ondas P50 e N95 apresentaram diferenças significativas na amplitude, latência e duração quando comparadas à s diversas faixas etárias, ocorrendo diminuição na amplitude das ondas e aumento na latência total do eletrorretinograma com o aumento da idade. ConstruÃram-se tabelas com intervalo de predição de 95% em relação à idade para a amplitude, latência e duração das curvas P50 e N95. CONCLUSÕES: A normatização do eletrorretinograma por reversão alternada proporciona a reprodutibilidade dos resultados e a possibilidade de estudos comparativos.50551
Conjunctival keratoacanthoma
Keratoacanthoma generally occurs on the skin; it is rarely found in the conjunctiva. A case of a 34-year-old woman with a rapidly growing conjunctival mass is reported. The tumor was excised with a safety margin to exclude squamous cell carcinoma. Histopathologically it was crateriform and consistent with atypical keratoacanthoma. There has been no recurrence in 2 years of follow-up. Conjunctival keratoacanthoma is rare; differential diagnosis of conventional squamous cell carcinoma and keratoacanthoma can be difficult. We recommend complete surgical excision and careful follow-up of crateriform squamous proliferations.Ceratoacantoma geralmente ocorre na pele e raramente é encontrado na conjuntiva. Relatamos um caso de uma mulher de 34 anos que apresentou uma massa conjuntival de rápido crescimento. O tumor foi retirado com margem de segurança para excluir carcinoma de células escamosas. Ao exame histopatológico, o tumor apresentou configuração crateriforme, sendo consistente com ceratoacantoma atÃpico. Não houve recorrência após dois anos de seguimento. Ceratoacantoma conjuntival é uma doença rara. Um diagnóstico diferencial entre carcinoma de células escamosas e ceratoacantoma pode ser difÃcil. Recomendamos total remoção e seguimento cuidadoso de pacientes com lesões escamosas crateriformes
Avaliação da camada de fibras nervosas da retina em pacientes com Doença de Alzheimer, utilizando o metodo do polarimetro de varredura a laser
Orientadores : Keila Mirian Monteiro de Carvalho, Jaime Antunes Maciel JrDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências MédicasResumo: A doença de Alzheimer é a forma mais comum de demência e afeta milhões de pessoas no mundo, aumentando sua prevalência com o aumento da expectativa de vida da população mundial. É caracterizada por uma deterioração da memória, linguagem, coordenação motora e reconhecimento visual. Existem evidências anátomofuncionais do acometimento no sistema visual periférico (retina e nervo óptico), onde são observadas uma diminuição da camada de células ganglionares da retina e no número de axônios no nervo óptico. Este estudo tem por objetivo comparar os resultados obtidos na avaliação da camada de fibras nervosas, utilizando o método do polarÃmetro de varredura a laser, em pacientes com doença de Alzheimer e indivÃduos normais da mesma faixa etária. Estudou-se prospectivamente 31 indivÃduos considerados neurologicamente normais e 11 indivÃduos com diagnóstico de doença de Alzheimer (DA) provável...Observação: O resumo, na Ãntegra, poderá ser visualizado no texto completo da tese digitalAbstract: Background: Defmite diagnosis of Alzheimer' s disease is only possible through neuropathological examintion and criteria for clinical diagnosis are esscntially basedon exclusion of other dementing conditions. Visual performance is impaired in patients with senile dementia of Alzheimer' s discasc. Purpose: To evaluate the effect of Alzheimer' s disease on retinal nerve fiber layer thickness measurements obtained with scanning laser polarimeter GOx- II...Note: The complete abstract is available with the full electronic digital thesis or dissertationsMestradoOftalmologiaMestre em Ciências Médica