5,458 research outputs found

    Molecular dynamics for fluid mechanics in arbitrary geometries

    Get PDF
    Simulations of nanoscale systems where fluid mechanics plays an important role are required to help design and understand nano-devices and biological systems. A simulation method which hybridises molecular dynamics (MD) and continuum computational fluid dynamics (CFD) models is able to accurately represent the relevant physical phenomena and be computationally tractable. An MD code has been written to perform MD simulations in systems where the geometry is described by a mesh of unstructured arbitrary polyhedral cells that have been spatially decomposed into irregular portions for parallel processing. The MD code that has been developed may be used for simulations on its own, or may serve as the MD component of a hybrid method. The code has been implemented using OpenFOAM, an open source C++ CFD toolbox (www.openfoam.org). The requirements for two key enabling components are described. 1) Parallel generation of initial configurations of molecules in arbitrary geometries. 2) Calculation of intermolecular pair forces, including between molecules that lie on mesh portions assigned to different, and possibly non-neighbouring processors. A case study of flow in a realistic nanoscale mixing channel, where the geometry is drawn and meshed in engineering CAD tools is simulated to demonstrate the capabilities of the code

    Molecular dynamics in arbitrary geometries : parallel evaluation of pair forces

    Get PDF
    A new algorithm for calculating intermolecular pair forces in molecular dynamics (MD) simulations on a distributed parallel computer is presented. The arbitrary interacting cells algorithm (AICA) is designed to operate on geometrical domains defined by an unstructured, arbitrary polyhedral mesh that has been spatially decomposed into irregular portions for parallelisation. It is intended for nano scale fluid mechanics simulation by MD in complex geometries, and to provide the MD component of a hybrid MD/continuum simulation. The spatial relationship of the cells of the mesh is calculated at the start of the simulation and only the molecules contained in cells that have part of their surface closer than the cut-off radius of the intermolecular pair potential are required to interact. AICA has been implemented in the open source C++ code OpenFOAM, and its accuracy has been indirectly verified against a published MD code. The same system simulated in serial and in parallel on 12 and 32 processors gives the same results. Performance tests show that there is an optimal number of cells in a mesh for maximum speed of calculating intermolecular forces, and that having a large number of empty cells in the mesh does not add a significant computational overhead

    Wages, racial composition, and quality sorting in labor markets

    Get PDF
    This paper examines the relationship between wage rates and the racial composition of jobs, using large cross-sectional and longitudinal samples constructed from monthly Current Population Surveys for 1983-92. Support is found for a "quality sorting" model that posits an equilibrium in which the racial composition of jobs serves as a skill index of unmeasured labor quality. Estimation of standard wage-level equations shows that wages of both black and white workers are substantially lower in occupations with a high density of blacks. Consistent with the quality sorting hypothesis, the magnitude of the relationship is reduced sharply after accounting for occupational skill measures. Longitudinal wage-change estimates controlling for person-specific quality indicate little if any causal effect of racial composition on wages. Estimates of racial discrimination are reduced only moderately after accounting for racial composition; unexplained differentials occur within occupations or reflect inter-occupational differences uncorrelated with racial composition and occupational skill measures.

    Can it be you that I hear?

    Get PDF
    This is the author accepted manuscript. The final version is available from the publisher via the DOI in this record.Editoria

    Geometric isomers of chloro(6-methyl-1,4,8,11-tetraazacyclotetradecane-6-amine)cobalt(III) tetrachlorozincate(II)

    Get PDF
    The crystal structures of a pair of cis and trans isomers of the macrocyclic chloropentaamine title complex, as their tetrachlorozincate(II) salts, [CoCl(C11H27N5)][ZnCl4], are reported. The two distinct isomeric forms lead to significant variations in the Co-N bond lengths and, furthermore, hydrogen bonding between the complex ions is influenced by the folded (cis) or planar (trans) conformations of the coordinated ligand

    Performance of formulae based estimates of glomerular filtration rate for carboplatin dosing in stage 1 seminoma

    Get PDF
    <b>Background:</b> Single cycle carboplatin, dosed by glomerular filtration rate (GFR), is standard adjuvant therapy for stage 1 seminoma. Accurate measurement of GFR is essential for correct dosing. Isotopic methods remain the gold standard for the determination of GFR. Formulae to estimate GFR have improved the assessment of renal function in non-oncological settings. We assessed the utility of these formulae for carboplatin dosing.<p></p> <b>Methods:</b> We studied consecutive subjects receiving adjuvant carboplatin for stage 1 seminoma at our institution between 2007 and 2012. Subjects underwent 51Cr-ethylene diamine tetra-acetic acid (EDTA) measurement of GFR with carboplatin dose calculated using the Calvert formula. Theoretical carboplatin doses were calculated from estimated GFR using Chronic Kidney Disease-Epidemiology (CKD-EPI), Management of Diet in Renal Disease (MDRD) and Cockcroft–Gault (CG) formulae with additional correction for actual body surface area (BSA). Carboplatin doses calculated by formulae were compared with dose calculated by isotopic GFR; a difference <10% was considered acceptable.<p></p> <b>Results:</b> 115 patients were identified. Mean isotopic GFR was 96.9 ml/min/1.73 m2. CG and CKD-EPI tended to overestimate GFR whereas MDRD tended to underestimate GFR. The CKD-EPI formula had greatest accuracy. The CKD-EPI formula, corrected for actual BSA, performed best; 45.9% of patients received within 10% of correct carboplatin dose. Patients predicted as underdosed (13.5%) by CKD-EPI were more likely to be obese (p = 0.013); there were no predictors of the 40.5% receiving an excess dose.<p></p> <b>Conclusions:</b> Our data support further evaluation of the CKD-EPI formula in this patient population but clinically significant variances in carboplatin dosing occur using non-isotopic methods of GFR estimation. Isotopic determination of GFR should remain the recommended standard for carboplatin dosing when accuracy is essential.<p></p&gt

    Planetary geosciences, 1989-1990

    Get PDF
    NASA's Planetary Geosciences Programs (the Planetary Geology and Geophysics and the Planetary Material and Geochemistry Programs) provide support and an organizational framework for scientific research on solid bodies of the solar system. These research and analysis programs support scientific research aimed at increasing our understanding of the physical, chemical, and dynamic nature of the solid bodies of the solar system: the Moon, the terrestrial planets, the satellites of the outer planets, the rings, the asteroids, and the comets. This research is conducted using a variety of methods: laboratory experiments, theoretical approaches, data analysis, and Earth analog techniques. Through research supported by these programs, we are expanding our understanding of the origin and evolution of the solar system. This document is intended to provide an overview of the more significant scientific findings and discoveries made this year by scientists supported by the Planetary Geosciences Program. To a large degree, these results and discoveries are the measure of success of the programs

    Charged Vacuum Bubble Stability

    Get PDF
    A type of scenario is considered where electrically charged vacuum bubbles, formed from degenerate or nearly degenerate vacuua separated by a thin domain wall, are cosmologically produced due to the breaking of a discrete symmetry, with the bubble charge arising from fermions residing within the domain wall. Stability issues associated with wall tension, fermion gas, and Coulombic effects for such configurations are examined. The stability of a bubble depends upon parameters such as the symmetry breaking scale and the fermion coupling. A dominance of either the Fermi gas or the Coulomb contribution may be realized under certain conditions, depending upon parameter values.Comment: 16 pages,revtex; accepted for publication in Phys.Rev.

    Seeing with sound? Exploring different characteristics of a visual-to-auditory sensory substitution device

    Get PDF
    Sensory substitution devices convert live visual images into auditory signals, for example with a web camera (to record the images), a computer (to perform the conversion) and headphones (to listen to the sounds). In a series of three experiments, the performance of one such device (‘The vOICe’) was assessed under various conditions on blindfolded sighted participants. The main task that we used involved identifying and locating objects placed on a table by holding a webcam (like a flashlight) or wearing it on the head (like a miner’s light). Identifying objects on a table was easier with a hand-held device, but locating the objects was easier with a head-mounted device. Brightness converted into loudness was less effective than the reverse contrast (dark being loud), suggesting that performance under these conditions (natural indoor lighting, novice users) is related more to the properties of the auditory signal (ie the amount of noise in it) than the cross-modal association between loudness and brightness. Individual differences in musical memory (detecting pitch changes in two sequences of notes) was related to the time taken to identify or recognise objects, but individual differences in self-reported vividness of visual imagery did not reliably predict performance across the experiments. In general, the results suggest that the auditory characteristics of the device may be more important for initial learning than visual associations
    • 

    corecore