991 research outputs found
Study on contraction and relaxation of experimentally denervated and immobilized muscles: Comparison with dystrophic muscles
The contraction-relaxation mechanism of experimentally denervated and immobilized muscles of the rabbit is examined. Results are compared with those of human dystrophic muscles, in order to elucidate the role and extent of the neurotrophic factor, and the role played by the intrinsic activity of muscle in connection with pathogenesis and pathophysiology of this disease
Operational status of TAMA300 with the seismic attenuation system (SAS)
TAMA300 has been upgraded to improve the sensitivity at low frequencies after the last observation run in 2004. To avoid the noise caused by seismic activities, we installed a new seismic isolation system —- the TAMA seismic attenuation system (SAS). Four SAS towers for the test-mass mirrors were sequentially installed from 2005 to 2006. The recycled Fabry–Perot Michelson interferometer was successfully locked with the SAS. We confirmed the reduction of both length and angular fluctuations at frequencies higher than 1 Hz owing to the SAS
Retinal glycoprotein enrichment by concanavalin a enabled identification of novel membrane autoantigen synaptotagmin-1 in equine recurrent uveitis.
Complete knowledge of autoantigen spectra is crucial for understanding pathomechanisms of autoimmune diseases like equine recurrent uveitis (ERU), a spontaneous model for human autoimmune uveitis. While several ERU autoantigens were identified previously, no membrane protein was found so far. As there is a great overlap between glycoproteins and membrane proteins, the aim of this study was to test whether pre-enrichment of retinal glycoproteins by ConA affinity is an effective tool to detect autoantigen candidates among membrane proteins. In 1D Western blots, the glycoprotein preparation allowed detection of IgG reactions to low abundant proteins in sera of ERU patients. Synaptotagmin-1, a Ca2+-sensing protein in synaptic vesicles, was identified as autoantigen candidate from the pre-enriched glycoprotein fraction by mass spectrometry and was validated as a highly prevalent autoantigen by enzyme-linked immunosorbent assay. Analysis of Syt1 expression in retinas of ERU cases showed a downregulation in the majority of ERU affected retinas to 24%. Results pointed to a dysregulation of retinal neurotransmitter release in ERU. Identification of synaptotagmin-1, the first cell membrane associated autoantigen in this spontaneous autoimmune disease, demonstrated that examination of tissue fractions can lead to the discovery of previously undetected novel autoantigens. Further experiments will address its role in ERU pathology
A new method to establish the rational extent of hepatic resection for advanced gallbladder cancer using dye injection through the cystic artery
BackgroundHepatic resection has been indicated to eliminate cancer at the surgical margin in cases of advanced gallbladder carcinoma, but there is considerable controversy about the reasonable extent of liver resection. A new on‐table dye injection technique has been introduced to determine the venous drainage of the gallbladder and ascertain the amount of liver to remove.MethodsIn four hepatic resections for pT2 gallbladder cancer, indocyanine green solution (25 mg/20 ml) was injected over a period of 30 seconds through the cystic artery. The stained area of the liver surface was completely resected, maintaining a margin of at least 2 cm from the gallbladder.ResultsThe entire serosal surface of the gallbladder takes on a light green stain immediately after dye injection, and then the liver surface around the gallbladder gradually becomes stained with a clear demarcation line. The distance between the demarcation line and the gallbladder ranged from 1.0 to 5.0 cm. The extent of the stained area differed from one individual to another. Histopathological examination of resected liver specimens revealed that one of the four resected livers had micrometastasis in the portal area 27 mm from the gallbladder wall and there were no cancer cells at the surgical margins. No recurrence has been seen in any of our 4 patients at 16–26 months after operation.DiscussionThe dye injection method is useful in determining the appropriate extent of hepatic resection for advanced gallbladder cancer, as it is possible to determine the necessary and sufficient amount of liver parenchyma that should be removed according to the perfusion area of the cystic veins in each individual patient
Current status of Japanese detectors
Current status of TAMA and CLIO detectors in Japan is reported in this
article. These two interferometric gravitational-wave detectors are being
developed for the large cryogenic gravitational wave telescope (LCGT) which is
a future plan for detecting gravitational wave signals at least once per year.
TAMA300 is being upgraded to improve the sensitivity in low frequency region
after the last observation experiment in 2004. To reduce the seismic noises, we
are installing new seismic isolation system, which is called TAMA Seismic
Attenuation System, for the four test masses. We confirmed stable mass locks of
a cavity and improvements of length and angular fluctuations by using two SASs.
We are currently optimizing the performance of the third and fourth SASs. We
continue TAMA300 operation and R&D studies for LCGT. Next data taking in the
summer of 2007 is planned.
CLIO is a 100-m baseline length prototype detector for LCGT to investigate
interferometer performance in cryogenic condition. The key features of CLIO are
that it locates Kamioka underground site for low seismic noise level, and
adopts cryogenic Sapphire mirrors for low thermal noise level. The first
operation of the cryogenic interferometer was successfully demonstrated in
February of 2006. Current sensitivity at room temperature is close to the
target sensitivity within a factor of 4. Several observation experiments at
room temperature have been done. Once the displacement noise reaches at thermal
noise level of room temperature, its improvement by cooling test mass mirrors
should be demonstrated.Comment: 6 pages, 5 figures, Proceedings of GWDAW-1
The linear variable differential transformer (LVDT) position sensor for gravitational wave interferometer low-frequency controls
Low-power, ultra-high-vacuum compatible, non-contacting position sensors with nanometer resolution and centimeter dynamic range have been developed, built and tested. They have been designed at Virgo as the sensors for low-frequency modal damping of Seismic Attenuation System chains in Gravitational Wave interferometers and sub-micron absolute mirror positioning. One type of these linear variable differential transformers (LVDTs) has been designed to be also insensitive to transversal displacement thus allowing 3D movement of the sensor head while still precisely reading its position along the sensitivity axis. A second LVDT geometry has been designed to measure the displacement of the vertical seismic attenuation filters from their nominal position. Unlike the commercial LVDTs, mostly based on magnetic cores, the LVDTs described here exert no force on the measured structure
- …