22 research outputs found

    Sealless Pumps

    Get PDF
    Discussion Grou

    Sealless Pumps

    Get PDF
    Discussion Grou

    Sealless Pumps

    Get PDF
    Discussion Grou

    Sealless Pumps

    Get PDF
    Discussion Grou

    Sealless Pumps

    Get PDF
    Discussion Grou

    Sealless Pumps

    Get PDF
    Discussion Grou

    Rates Of Amyloid Imaging Positivity In Patients With Primary Progressive Aphasia

    Get PDF
    IMPORTANCE The ability to predict the pathology underlying different neurodegenerative syndromes is of critical importance owing to the advent of molecule-specific therapies. OBJECTIVE To determine the rates of positron emission tomography (PET) amyloid positivity in the main clinical variants of primary progressive aphasia (PPA). DESIGN, SETTING, AND PARTICIPANTS This prospective clinical-pathologic case series was conducted at a tertiary research clinic specialized in cognitive disorders. Patients were evaluated as part of a prospective, longitudinal research study between January 2002 and December 2015. Inclusion criteria included clinical diagnosis of PPA; availability of complete speech, language, and cognitive testing; magnetic resonance imaging performed within 6 months of the cognitive evaluation; and PET carbon 11-labeled Pittsburgh Compound-B or florbetapir F 18 brain scan results. Of 109 patients referred for evaluation of language symptoms who underwent amyloid brain imaging, 3 were excluded because of incomplete language evaluations, 5 for absence of significant aphasia, and 12 for presenting with significant initial symptoms outside of the language domain, leaving a cohort of 89 patients with PPA. MAIN OUTCOMES AND MEASURES Clinical, cognitive, neuroimaging, and pathology results. RESULTS Twenty-eight cases were classified as imaging-supported semantic variant PPA (11 women [39.3%]; mean [SD] age, 64 [7] years), 31 nonfluent/agrammatic variant PPA (22 women [71.0%]; mean [SD] age, 68 [7] years), 26 logopenic variant PPA (17 women [65.4%]; mean [SD] age, 63 [8] years), and 4 mixed PPA cases. Twenty-four of 28 patients with semantic variant PPA (86%) and 28 of 31 patients with nonfluent/agrammatic variant PPA (90%) had negative amyloid PET scan results, while 25 of 26 patients with logopenic variant PPA (96%) and 3 of 4 mixed PPA cases (75%) had positive scan results. The amyloid positive semantic variant PPA and nonfluent/agrammatic variant PPA cases with available autopsy data (2 of 4 and 2 of 3, respectively) all had a primary frontotemporal lobar degeneration and secondary Alzheimer disease pathologic diagnoses, whereas autopsy of 2 patients with amyloid PET-positive logopenic variant PPA confirmed Alzheimer disease. One mixed PPA patient with a negative amyloid PET scan had Pick disease at autopsy. CONCLUSIONS AND RELEVANCE Primary progressive aphasia variant diagnosis according to the current classification scheme is associated with Alzheimer disease biomarker status, with the logopenic variant being associated with carbon 11-labeled Pittsburgh Compound-B positivity in more than 95% of cases. Furthermore, in the presence of a clinical syndrome highly predictive of frontotemporal lobar degeneration pathology, biomarker positivity for Alzheimer disease may be associated more with mixed pathology rather than primary Alzheimer disease

    Effectiveness of electronic guideline-based implementation systems in ambulatory care settings - a systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Electronic guideline-based decision support systems have been suggested to successfully deliver the knowledge embedded in clinical practice guidelines. A number of studies have already shown positive findings for decision support systems such as drug-dosing systems and computer-generated reminder systems for preventive care services.</p> <p>Methods</p> <p>A systematic literature search (1990 to December 2008) of the English literature indexed in the Medline database, Embase, the Cochrane Central Register of Controlled Trials, and CRD (DARE, HTA and NHS EED databases) was conducted to identify evaluation studies of electronic multi-step guideline implementation systems in ambulatory care settings. Important inclusion criterions were the multidimensionality of the guideline (the guideline needed to consist of several aspects or steps) and real-time interaction with the system during consultation. Clinical decision support systems such as one-time reminders for preventive care for which positive findings were shown in earlier reviews were excluded. Two comparisons were considered: electronic multidimensional guidelines versus usual care (comparison one) and electronic multidimensional guidelines versus other guideline implementation methods (comparison two).</p> <p>Results</p> <p>Twenty-seven publications were selected for analysis in this systematic review. Most designs were cluster randomized controlled trials investigating process outcomes more than patient outcomes. With success defined as at least 50% of the outcome variables being significant, none of the studies were successful in improving patient outcomes. Only seven of seventeen studies that investigated process outcomes showed improvements in process of care variables compared with the usual care group (comparison one). No incremental effect of the electronic implementation over the distribution of paper versions of the guideline was found, neither for the patient outcomes nor for the process outcomes (comparison two).</p> <p>Conclusions</p> <p>There is little evidence at the moment for the effectiveness of an increasingly used and commercialised instrument such as electronic multidimensional guidelines. After more than a decade of development of numerous electronic systems, research on the most effective implementation strategy for this kind of guideline-based decision support systems is still lacking. This conclusion implies a considerable risk towards inappropriate investments in ineffective implementation interventions and in suboptimal care.</p

    Continuous Monitoring Of Sealless Pumps - The Next Step

    No full text
    Lecturepg. 125All centrifugal sealless pumps, both canned motor and magnetic drive, should be monitored to determine mechanical condition. In sealless pumps, the pumped fluid is used as the cooling and lubricating medium for the pump bearings. If intermittent monitoring is used, then the chance of detecting pump damage caused by process changes is very small. Vibration monitoring techniques as applied to sealed pumps has been unreliable for detecting problems with sealless pumps. The effectiveness of conventional monitoring techniques is limited by the time interval between measurements, the relative isolation of the inner pump rotor from the outer measuring location, and by the pump fluid. Other factors such as fluid effects and process noises can make interpretation difficult. This paper presents the synergistic combination of two relatively new methods of sealless pump monitoring. These methods considerably enhance the range and magnitude of the mechanical problems that can be identified on this type of pump. One of the goals of predictive maintenance is the reduction of maintenance costs by use of condition monitoring. Identification of off-design operation conditions or mechanical damage at an early stage enables the equipment owner to correct the conditions before damage occurs, or to optimally schedule repairs. Continuous monitoring of sealless pumps, can reduce equipment maintenance costs and facilitate root cause analysis of mechanical failures and operational problems. This cost reduction is accomplished by the use of the monitoring system to immediately identify conditions that can lead to failure

    Arkansas poor farm collection

    No full text
    This collection contains research on community indigent care facilities in Arkansas (also known as poor farms or poorhouses) prior to the creation of national social programs
    corecore