207 research outputs found
Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1
The DEAP-1 low-background liquid argon detector was used to measure
scintillation pulse shapes of electron and nuclear recoil events and to
demonstrate the feasibility of pulse-shape discrimination (PSD) down to an
electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction
of beta events that are misidentified as nuclear recoils to be (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil
acceptance of at least 90%, with 4% systematic uncertainty on the absolute
energy scale. The discrimination measurement on surface was limited by nuclear
recoils induced by cosmic-ray generated neutrons. This was improved by moving
the detector to the SNOLAB underground laboratory, where the reduced background
rate allowed the same measurement with only a double-coincidence tag.
The combined data set contains events. One of those, in the
underground data set, is in the nuclear-recoil region of interest. Taking into
account the expected background of 0.48 events coming from random pileup, the
resulting upper limit on the electronic recoil contamination is
(90% C.L.) between 44-89 keVee and for a nuclear recoil
acceptance of at least 90%, with 6% systematic uncertainty on the absolute
energy scale.
We developed a general mathematical framework to describe PSD parameter
distributions and used it to build an analytical model of the distributions
observed in DEAP-1. Using this model, we project a misidentification fraction
of approx. for an electron-equivalent energy threshold of 15 keV for
a detector with 8 PE/keVee light yield. This reduction enables a search for
spin-independent scattering of WIMPs from 1000 kg of liquid argon with a
WIMP-nucleon cross-section sensitivity of cm, assuming
negligible contribution from nuclear recoil backgrounds.Comment: Accepted for publication in Astroparticle Physic
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Many current and future dark matter and neutrino detectors are designed to
measure scintillation light with a large array of photomultiplier tubes (PMTs).
The energy resolution and particle identification capabilities of these
detectors depend in part on the ability to accurately identify individual
photoelectrons in PMT waveforms despite large variability in pulse amplitudes
and pulse pileup. We describe a Bayesian technique that can identify the times
of individual photoelectrons in a sampled PMT waveform without deconvolution,
even when pileup is present. To demonstrate the technique, we apply it to the
general problem of particle identification in single-phase liquid argon dark
matter detectors. Using the output of the Bayesian photoelectron counting
algorithm described in this paper, we construct several test statistics for
rejection of backgrounds for dark matter searches in argon. Compared to simpler
methods based on either observed charge or peak finding, the photoelectron
counting technique improves both energy resolution and particle identification
of low energy events in calibration data from the DEAP-1 detector and
simulation of the larger MiniCLEAN dark matter detector.Comment: 16 pages, 16 figure
In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum
efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and
is of significant interest for future dark matter and neutrino experiments
where high signal yields are needed.
We report on the methods developed for in-situ characterization and
monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of
typical measured single-photoelectron charge distributions, correlated noise
(afterpulsing), dark noise, double, and late pulsing characteristics. The
characterization is performed during the detector commissioning phase using
laser light injected through a light diffusing sphere and during normal
detector operation using LED light injected through optical fibres
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was
operated underground at SNOLAB in order to test the techniques and measure the
backgrounds inherent to single phase detection, in support of the
\mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled
through material selection, construction techniques, pulse shape discrimination
and event reconstruction. This report details the analysis of background events
observed in three iterations of the DEAP-1 detector, and the measures taken to
reduce them.
The Rn decay rate in the liquid argon was measured to be between 16
and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background
spectrum near the region of interest for Dark Matter detection in the DEAP-1
detector can be described considering events from three sources: radon
daughters decaying on the surface of the active volume, the expected rate of
electromagnetic events misidentified as nuclear recoils due to inefficiencies
in the pulse shape discrimination, and leakage of events from outside the
fiducial volume due to imperfect position reconstruction. These backgrounds
statistically account for all observed events, and they will be strongly
reduced in the DEAP-3600 detector due to its higher light yield and simpler
geometry
Multitarget Stool DNA Test Performance in an Average-Risk Colorectal Cancer Screening Population
INTRODUCTION: We set out to evaluate the performance of a multitarget stool DNA (MT-sDNA) in an average-risk colonoscopy-controlled colorectal cancer (CRC) screening population. MT-sDNA stool test results were evaluated against fecal immunochemical test (FIT) results for the detection of different lesions, including molecularly defined high-risk adenomas and several other tumor characteristics. METHODS: Whole stool samples (n = 1,047) were prospectively collected and subjected to an MT-sDNA test, which tests for KRAS mutations, NDRG4 and BMP3 promoter methylation, and hemoglobin. Results for detecting CRC (n = 7), advanced precancerous lesions (advanced adenoma [AA] and advanced serrated polyps; n = 119), and non-AAs (n = 191) were compared with those of FIT alone (thresholds of 50, 75, and 100 hemoglobin/mL). AAs with high risk of progression were defined by the presence of specific DNA copy number events as measured by low-pass whole genome sequencing. RESULTS: The MT-sDNA test was more sensitive than FIT alone in detecting advanced precancerous lesions (46% (55/119) vs 27% (32/119), respectively, P < 0.001). Specificities among individuals with nonadvanced or negative findings (controls) were 89% (791/888) and 93% (828/888) for MT-sDNA and FIT testing, respectively. A positive MT-sDNA test was associated with multiple lesions (P = 0.005), larger lesions (P = 0.03), and lesions with tubulovillous architecture (P = 0.04). The sensitivity of the MT-sDNA test or FIT in detecting individuals with high-risk AAs (n = 19) from individuals with low-risk AAs (n = 52) was not significantly different. DISCUSSION: In an average-risk screening population, the MT-sDNA test has an increased sensitivity for detecting advanced precancerous lesions compared with FIT alone. AAs with a high risk of progression were not detected with significantly higher sensitivity by MT-sDNA or FIT
Measurement of the 8B solar neutrino flux in SNO+ with very low backgrounds
A measurement of the 8B solar neutrino flux has been made using a 69.2 kt-day dataset acquired with the SNO+ detector during its water commissioning phase. At energies above 6 MeV the dataset is an extremely pure sample of solar neutrino elastic scattering events, owing primarily to the detector’s deep location, allowing an accurate measurement with relatively little exposure. In that energy region the best fit background rate is 0.25+0.09−0.07  events/kt−day, significantly lower than the measured solar neutrino event rate in that energy range, which is 1.03+0.13−0.12  events/kt−day. Also using data below this threshold, down to 5 MeV, fits of the solar neutrino event direction yielded an observed flux of 2.53+0.31−0.28(stat)+0.13−0.10(syst)×106  cm−2 s−1, assuming no neutrino oscillations. This rate is consistent with matter enhanced neutrino oscillations and measurements from other experiments
First results from the DEAP-3600 dark matter search with argon at SNOLAB
This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produced by rare nuclear recoil signals induced by dark matter particle scattering. An analysis of 4.44 live days (fidicial exposure of 9.87 tonne days) of data taken during the initial filling phase demonstrates the best electronic recoil rejection using pulse-shape discrimination in argon, with leakage <1.2X107 (90% C.L.) between 15 and 31 keVee. No candidate signal events
are observed, which results in the leading limit on WIMP-nucleon spin-independent cross section on argon, <1.21044 cm2 for a 100 GeV/c2 WIMP mass (90% C.L.)
Design and construction of the DEAP-3600 dark matter detector
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is 10−46cm2 for a 100 GeV/c2 WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the physical properties and construction of the DEAP-3600 detector
- …