91 research outputs found

    High-power, tunable source of coherent THz radiation driven by a microbunched electron beam

    No full text
    "Pre-bunched"or "microbunched"charged particle beams have attracted significant interest in the last decade. Potential applications of such beams include development of the next generation of THz and X-ray light sources. This work presents the conceptual design of a tunable source of coherent Smith-Purcell THz radiation based on plasma-assisted pre-modulation of the continuous beam, and conditioning of the micro-bunched beam. The numerical simulations were carried out from the beam modulation to THz radiation generation using a self-consistent numerical model as well as a semi-analytical approach. Such a source would be a possible and useful alternative to conventional vacuum THz tubes and THz FEL sources

    Concept of a tunable source of coherent THz radiation driven by a plasma modulated electron beam

    No full text
    We have carried out numerical studies which consider the modulation of a picosecond long relativistic electron beam in a plasma channel and the generation of a micro-bunched train. The subsequent propagation of the micro-bunched beam in the vacuum area was also investigated. The same numerical model was then used to simulate the radiation arising from the interaction of the micro-bunched beam with a metallic grating. The dependence of the radiation spectrum on the parameters of the micro-bunched beam has been studied and the tunability of the radiation by the variation of the micro-bunch spacing has been demonstrated. The micro-bunch spacing can be changed easily by altering the plasma density without changing the beam energy or current. Using the results of these studies, we develop a conceptual design of a tunable source of coherent terahertz (THz) radiation driven by a plasma modulated beam. Such a source would be a potential and useful alternative to conventional vacuum THz tubes and THz free-electron laser sources

    Novel grating designs for a single-shot Smith-Purcell bunch profile monitor

    No full text
    Smith-Purcell radiation has been successfully used to perform longitudinal profile measurements of electron bunches with sub-ps lengths. These measurements require radiation to be generated from a series of gratings to cover a sufficient frequency range for accurate profile reconstruction. In past systems the gratings were used sequentially and so several bunches were required to generate a single profile, but modern accelerators would benefit from such measurements being performed on a bunch by bunch basis. To do this the radiation from all three gratings would need to be measured simultaneously, increasing the mechanical complexity of the device as each grating would need to be positioned individually and at a different azimuthal angle around the electron beam. Investigations into gratings designed to displace the radiation azimuthally will be presented. Such gratings could provide an alternative to the rotated-grating approach, and would simplify the design of the single-shot monitor by reducing the number of motors required as all of the gratings could be positioned using a single mount

    Experimental investigation of phase shifting in 1D Bragg structures for high power microwave pulse compression

    Get PDF
    The study of the quantum phase-space distribution of quarks and gluons inside nucleons in terms of TMDs and GPDs has become, in the last decade, a cutting-edge research field in hadron physics. These non-perturbative objects, respectively measurable in semi-inclusive deep-inelastic scattering and exclusive processes, allow to obtain 3-dimensional representations of the nucleon in the momentum and spatial coordinates as well as indirect insights into the still unknown parton orbital angular momentum. The HERMES experiment at HERA has been a precursor in this field. A selection of HERMES results sensitive to both TMDs and GPDs is presented

    Novel grating designs for a single-shot Smith-Purcell bunch profile monitor

    No full text
    Smith-Purcell radiation has been successfully used to perform longitudinal profile measurements of electron bunches with sub-ps lengths. These measurements require radiation to be generated from a series of gratings to cover a sufficient frequency range for accurate profile reconstruction. In past systems the gratings were used sequentially and so several bunches were required to generate a single profile, but modern accelerators would benefit from such measurements being performed on a bunch by bunch basis. To do this the radiation from all three gratings would need to be measured simultaneously, increasing the mechanical complexity of the device as each grating would need to be positioned individually and at a different azimuthal angle around the electron beam. Investigations into gratings designed to displace the radiation azimuthally will be presented. Such gratings could provide an alternative to the rotated-grating approach, and would simplify the design of the single-shot monitor by reducing the number of motors required as all of the gratings could be positioned using a single mount

    Studies of high order modes in asymmetric dual-axis cavity

    No full text
    Electron-beam current in superconducting radiofrequency energy recovery linear accelerators (SCRF ERLs) is limited by beam break-up (BBU) instabilities disrupting beam transport and energy recuperation. The instabilities originate from the accumulation of high order modes (HOMs) in the cavity and positive feedback between the beam and HOMs which is especially evident in multi-pass ERLs. Overcoming the beam current limitations due to BBU instabilities is one of the challenges in accelerator science. A dual-axis asymmetric SCRF ERL has been proposed as a possible way to drive a high average current electron beam for next-generation light sources and beam cooling in electron-ion colliders (EICs). In this work, detailed studies on HOMs in the asymmetric dual axis cavity were carried out. The asymmetric field distribution of HOMs (i.e., confinement to one or another axis) has been demonstrated and their excitation from different axes has been studied. The results confirm the numerical predictions and theory developed to describe the asymmetric dual axis cavity
    corecore