59 research outputs found

    Evaluation of the effectiveness of V-Y plasty of frozen Achilles tendon rupture, with immediate follow-up weight-bearing and rehabilitation. Case analysis

    Get PDF
    The Achilles tendon is a strong tendon in the human body but is prone to rupture, especially during recreational activities. Misdiagnosis of ruptures can lead to chronic issues, affecting the quality of life. Surgical V-Y plasty is a technique used to treat chronic Achilles tendon ruptures by lengthening the tendon and restoring its continuity. Two cases of Achilles tendon ruptures were presented, where V-Y plasty was performed along with immediate weight-bearing and rehabilitation. The patients showed significant improvement post-surgery, with no symptoms or restrictions on physical activity after about 6 months. The rehabilitation protocol included functional training, regenerative treatments, and follow-up visits to monitor progress. Studies have shown that surgical treatment is more effective in preventing re-tears compared to conservative treatment for Achilles tendon ruptures. V-Y plasty has been proven to be an effective technique for treating chronic ruptures with large defects in tendon continuity. Immediate weight-bearing and rehabilitation post-surgery have shown positive outcomes in patient recovery. Further research is needed to establish a standardized rehabilitation protocol for Achilles tendon ruptures. The unique management regimen used in the cases presented yielded successful results, emphasizing the importance of immediate rehabilitation post-surgery for improved patient outcomes. V-Y plasty with immediate weight-bearing and rehabilitation is a promising method for treating chronic Achilles tendon ruptures

    Studies of discrete symmetries in decays of positronium atoms

    Get PDF
    A positronium - a bound state of electron and positron - is an eigenstate of parity and charge conjugation operators which decays into photons. It is a unique laboratory to study discrete symmetries whose precision is limited, in principle, by the effects due to the weak interactions expected at the level of 10−14 and photon-photon interactions expected at the level of 10−9. The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging as well as for physics studies involving detection of electronpositron annihilation into photons. The physics case covers the areas of discrete symmetries studies and genuine multipartite entanglement. The J-PET detector has high angular and time resolution and allows for determination of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present the potential of the J-PET system for studies of discrete symmetries in decays of positronium atoms

    Analysis procedure of the positronium lifetime spectra for the J-PET detector

    Get PDF
    Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the J-PET (Jagiellonian PET), will allow PALS in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the J-PET software. We compare its performance with the standard program LT 9.0 by using PALS data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.Comment: 4 figures, 8 page

    Feasibility study of the time reversal symmetry tests in decay of metastable positronium atoms with the J-PET detector

    Get PDF
    This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in nonvanishing angular correlations of final state observables in the decay of metastable triplet states of positronium available with J-PET are proposed and discussed. Results of a pilot measurement with J-PET and assessment of its performance in reconstruction of three-photon decays are shown along with an analysis of its impact on the sensitivity of the detector for the determination of T-violation sensitive observables

    Introduction of total variation regularization into filtered backprojection algorithm

    Get PDF
    In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image of radioactive tracer distribution using standard Derenzo-type phantom. We demonstrate that the proposed approach results in higher cross-correlation values with respect to the standard FBP method

    A method to produce linearly polarized positrons and positronium atoms with the J-PET detector

    Get PDF
    A method for creating linearly polarized positrons and ortho-positronium (o-Ps) atoms with the J-PET detector is presented. The unique geometry and properties of the J-PET tomography enable one to design a positron source such that the quantization axis for the estimation of the linear polarization of produced o-Ps can be determined on the event by event basis in a direction of the positron motion. We intend to use ²²Na or other β⁺ decay isotopes as a source of polarized positrons. Due to the parity violation in the beta decay, the emitted positrons are longitudinally polarized. The choice of the quantization axis is based on the known position of the positron emitter and the reconstructed position of the positronium annihilation. We show that the J-PET tomography is equipped with all needed components

    Time calibration of the J-PET detector

    Get PDF
    The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a 22Na source and a small detector providing common reference time for synchronization of all the modules

    Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy

    Get PDF
    The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of analysis of the positron lifetime measured in the porous polymer. The obtained results prove that J-PET is capable of performing simultaneous imaging of the density distribution of annihilation points as well as positron annihilation lifetime spectroscopy

    Preliminary studies of J-PET detector spatial resolution

    Get PDF
    The J-PET detector, based on long plastic scintillator strips, was recently constructed at the Jagiellonian University. It consists of 192 modules axially arranged into three layers, read out from both sides by digital constant-threshold front-end electronics. This work presents preliminary results of measurements of the spatial resolution of the J-PET tomograph performed with ²²Na source placed at selected position inside the detector chamber

    Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography

    Get PDF
    Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron–positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10−4, with an over threefold improvement on the previous measurement
    corecore