    Don't forget the memory: Contribution of the T wave vector in localizing the site of origin of a monomorphic idiopathic ventricular tachycardia

    Get PDF
    SummaryWe report a case of cardiac memory following recurrent episodes of monomorphic idiopathic ventricular tachycardia and explain how it could be helpful in localizing the site of origin of the arrhythmia

    Characterization of Respiratory and Cardiac Motion from Electro-Anatomical Mapping Data for Improved Fusion of MRI to Left Ventricular Electrograms

    Get PDF
    Accurate fusion of late gadolinium enhancement magnetic resonance imaging (MRI) and electro-anatomical voltage mapping (EAM) is required to evaluate the potential of MRI to identify the substrate of ventricular tachycardia. However, both datasets are not acquired at the same cardiac phase and EAM data is corrupted with respiratory motion limiting the accuracy of current rigid fusion techniques. Knowledge of cardiac and respiratory motion during EAM is thus required to enhance the fusion process. In this study, we propose a novel approach to characterize both cardiac and respiratory motion from EAM data using the temporal evolution of the 3D catheter location recorded from clinical EAM systems. Cardiac and respiratory motion components are extracted from the recorded catheter location using multi-band filters. Filters are calibrated for each EAM point using estimates of heart rate and respiratory rate. The method was first evaluated in numerical simulations using 3D models of cardiac and respiratory motions of the heart generated from real time MRI data acquired in 5 healthy subjects. An accuracy of 0.6–0.7 mm was found for both cardiac and respiratory motion estimates in numerical simulations. Cardiac and respiratory motions were then characterized in 27 patients who underwent LV mapping for treatment of ventricular tachycardia. Mean maximum amplitude of cardiac and respiratory motion was 10.2±2.7 mm (min = 5.5, max = 16.9) and 8.8±2.3 mm (min = 4.3, max = 14.8), respectively. 3D Cardiac and respiratory motions could be estimated from the recorded catheter location and the method does not rely on additional imaging modality such as X-ray fluoroscopy and can be used in conventional electrophysiology laboratory setting

    Task force VII: Arrhythmias and specialized electrophysiologic studies

    Get PDF

    Cardiovascular Magnetic Resonance Imaging of Scar Development Following Pulmonary Vein Isolation: A Prospective Study

    Get PDF
    Aims Cardiovascular magnetic resonance (MR) provides non-invasive assessment of early (24-hour) edema and injury following pulmonary vein isolation (by ablation) and subsequent scar formation. We hypothesize that 24-hours after ablation, cardiovascular MR would demonstrate a pattern of edema and injury due to ablation and the severity would correlate with subsequent scar. Methods: Fifteen atrial fibrillation patients underwent cardiovascular MR prior to pulmonary vein isolation, 24-hours post (N = 11) and 30-days post (N = 7) ablation, with T2-weighted (T2W) and late gadolinium enhancement (LGE) imaging. Left atrial wall thickness, edema enhancement ratio and LGE enhancement were assessed at each time point. Volumes of LGE and edema enhancement were measured, and the circumferential presence of injury was assessed at 24-hours, including comparison with LGE enhancement at 30 days. Results: Left atrial wall thickness was increased 24-hours post-ablation (10.7±4.1 mm vs. 7.0±1.8 mm pre-PVI, p<0.05). T2W enhancement at 24-hours showed increased edema enhancement ratio (1.5±0.4 for post-ablation, vs. 0.9±0.2 pre-ablation, p<0.001). Edema and LGE volumes at 24-hours were correlated with 30-day LGE volume (R = 0.76, p = 0.04, and R = 0.74, p = 0.09, respectively). Using a 16 segment model for assessment, 24-hour T2W had sensitivity, specificity, and accuracy of 82%, 63%, and 79% respectively, for predicting 30-day LGE. 24-hour LGE had sensitivity, specificity, and accuracy of 91%, 47%, and 84%. Conclusions: Increased left atrial wall thickening and edema were characterized on cardiovascular MR early post-ablation, and found to correlate with 30-day LGE scar

    Usefulness of electrophysiologic study to determine the clinical tolerance of arrhythmia recurrences during amiodarone therapy

    Get PDF
    The relation of clinical and electrophysiologic variables to outcome was evaluated in 121 patients treated with amiodarone for sustained ventricular tachyarrhythmias. Electrophysiologic study was performed in all patients a mean of 14 days after beginning amiodarone therapy. Forty-six patients who were given oral amiodarone therapy experienced arrhythmia recurrence. Multivariate analysis was performed using 16 clinical and electrophysiologic variables to determine which factors were associated with 1) arrhythmia recurrence and 2) a poorly tolerated arrhythmia recurrence (that is, cardiac arrest or sudden cardiac death) during oral amiodarone therapy. No variable predicted arrhythmia recurrence. Five variables correlated significantly with a poorly tolerated arrhythmia recurrence. Hemodynamic stability of the arrhythmia induced on electrophysiologic testing during amiodarone therapy had the best predictive value (p < 0.001). Younger age, lower ejection fraction, a poorly tolerated rhythm at clinical presentation and absence of left ventricular aneurysm were also associated with a poorly tolerated arrhythmia recurrence.Only 3 of 57 patients who had a well tolerated arrhythmia induced on electrophysiologic testing during amiodarone therapy had recurrence of a poorly tolerated arrhythmia versus 19 of 47 who had hemodynamically unstable arrhythmias induced during amiodarone therapy (p < 0.001). Thus, electrophysiologic testing during amiodarone therapy appears useful in identifying patients who are prone to have catastrophic arrhythmia recurrences and could allow for the institution of additional or alternative modes of therapy

    Accuracy of electrocardiographic criteria for atrial enlargement: validation with cardiovascular magnetic resonance

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Anatomic atrial enlargement is associated with significant morbidity and mortality. However, atrial enlargement may not correlate with clinical measures such as electrocardiographic (ECG) criteria. Past studies correlating ECG criteria with anatomic measures mainly used inferior M-mode or two-dimensional echocardiographic data. We sought to determine the accuracy of the ECG to predict anatomic atrial enlargement as determined by volumetric cardiovascular magnetic resonance (CMR).</p> <p>Methods</p> <p>ECG criteria for left (LAE) and right atrial enlargement (RAE) were compared to CMR atrial volume index measurements for 275 consecutive subjects referred for CMR (67% males, 51 ± 14 years). ECG criteria for LAE and RAE were assessed by an expert observer blinded to CMR data. Atrial volume index was computed using the biplane area-length method.</p> <p>Results</p> <p>The prevalence of CMR LAE and RAE was 28% and 11%, respectively, and by any ECG criteria was 82% and 5%, respectively. Though nonspecific, the presence of at least one ECG criteria for LAE was 90% sensitive for CMR LAE. The individual criteria P mitrale, P wave axis < 30°, and negative P terminal force in V1 (NPTF-V1) > 0.04s·mm were 88–99% specific although not sensitive for CMR LAE. ECG was insensitive but 96–100% specific for CMR RAE.</p> <p>Conclusion</p> <p>The presence of at least one ECG criteria for LAE is sensitive but not specific for anatomic LAE. Individual criteria for LAE, including P mitrale, P wave axis < 30°, or NPTF-V1 > 0.04s·mm are highly specific, though not sensitive. ECG is highly specific but insensitive for RAE. Individual ECG P wave changes do not reliably both detect and predict anatomic atrial enlargement.</p
    • …