123 research outputs found

    ACTIVITY OF SERRATUS ANTERIOR, UPPER AND LOWER TRAPEZIUS DURING ARM ABDUCTION IN MULTIDIRECTIONAL INSTABILITY.

    Get PDF
    Multidirectional instability of the shoulder is a complex entity and it appears that factors in addition to excessive capsular laxity play a pathophysiologic role. So the objective of this study is to compare the electromyography activity of the scapular muscles during abduction and adduction of shoulder in athletes with multidirectional instability and abnormal scapulothoracic motion with individual without lesion

    Mensuração da lordose lombar em posição ortostática: revisão da literatura

    Get PDF
    Physical therapists must prevent and properly treat postural changes, among which lumbar lordosis increase or decrease. Several methods are used to measure lumbar lordosis angle in standing position. In clinical practice, accurate lordosis measurement, through valid and reliable methods, enable adequate postural evaluation and treatment. The aim of this study was to review articles on the various ways of measuring lumbar lordosis angle in orthostatic posture, both in healthy and altered-posture individuals. The search in data bases and specialised journals led to 44 articles, of which 18 were selected for their assessing inter and/or intratester reliability, or between different measuring techniques or instruments. In reviewed studies main instruments of lumbar lordosis assessment were: visual evaluation by photography, posture classification, scale tool, flexible ruler, goniometer, computer software, and radiography. The value found for the angle of the lumbar lordosis varied between 23º and 66.1º, reflecting different spinal regions measured by each method. Since no measuring method proved both practical and reliable, further research seems necessary in order to establish a form of measuring lumbar lordosis angle to be taught and applied in physical therapy clinical practice.Cabe ao fisioterapeuta prevenir e tratar adequadamente alterações posturais, dentre as quais o aumento ou diminuição da lordose lombar. Para verificar tais alterações, vários métodos são utilizados para medir o ângulo da lordose em posição ortostática. Na prática clínica, a precisão dessa mensuração, usando instrumentos confiáveis e validados, permite avaliação postural e plano de tratamento adequados. Este estudo visou revisar e avaliar as formas de mensuração do ângulo da lordose lombar em indivíduos sadios ou com alterações musculoesqueléticas em posição ortostática. A busca em bases de dados e revistas especializadas levou ao exame de 44 artigos, dos quais 18 foram incluídos nesta revisão, por referirem a avaliação da confiabilidade intra e/ou interobservadores, ou entre instrumentos e/ou técnicas utilizadas. Nos estudos, os principais meios de avaliação da lordose lombar avaliados foram: visual, por meio de fotografia, classificação da postura, instrumento-escala, régua flexível, goniômetro, programas de computador e radiografia. O valor encontrado para o ângulo da lordose lombar variou entre 23º e 66,1º, refletindo as diferentes regiões medidas com cada instrumento. Não foi possível chegar a um consenso sobre um método de mensuração prático e confiável, o que sugere a necessidade de mais estudos para alcançar um consenso naforma de mensuração, a ser ensinada e adotada na prática clínica da fisioterapia

    LOWER EXTREMITY POSITION INFLUENCE ON THE POSTURAL STABILITY INDEX REGISTERED BY THE BIODEX STABILITY SYSTEM

    Get PDF
    The Biodex Balance System is a multiaxial device that objectively measures and records an individual’s ability to stabilize the determined joint under dynamic stress. Some authors describe the importance of knee position strategy for stabilizing balance in this situation; however, the reliability of each knee position is underestimated. With this the objective of this study is to compare intrarater reliability of two knee position situations in the Biodex Balance System test

    ELECTROMYOGRAPHY DURING AQUATIC CYCLING IN DIFFERENT CADENCES: PILOT STUDY

    Get PDF
    The effects of cadence and load on lower limb muscles activities using electromyography (EMG) are well documented in cycling literature (Baum and Li, 2003). They reported that increase of cadence displayed a non significant reduction of the EMG for Biceps Femoris (BF) and Vastus Lateralis (VL); however, with an increased load there was an increase in the EMG in both muscles when used Monarch cycle ergometer. They attributed this reduction of the EMG in relation to cadence to increase of inertial influence on pedal force. The aim of this study is to verify influence of cadences (50 and 65rpm) on lower limb muscles activities (BF and VL) using aquatic cycle ergometry (ACE)

    Uma avaliação comparativa das técnicas de caracterização das distorções harmônicas

    Get PDF
    Monografia (graduação)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2014.Este trabalho apresenta uma avaliação comparativa de cinco técnicas de caracterização das distorções harmônicas de tensão. Inicialmente, são apresentadas as definições, as causas, os efeitos e as normas deste fenômeno. Apresenta-se os fundamentos teóricos das técnicas empregadas na análise, sendo elas: Algoritmo de Goertzel, Transformada de Fourier, Transformada de Hartley, Mínimos Quadrados para Harmônicas e Levenberg-Marquard. Para situar o leitor com relação aos estudos desenvolvidos sobre este tema, é apresentado o Estado da Arte. Empregando-se sinais com distorções harmônicas conhecidas e fazendo-se uso da variação de parâmetros característicos da rede elétrica e dos instrumentos de medição em simulações computacionais, foi possível classificar os métodos através dos erros na caracterização das distorções harmônicas, além de identificar como os parâmetros influenciam os métodos. O método de Levenberg-Marquard obteve os melhores resultados nas avaliações realizadas. Porém, ele apresentou o pior tempo computacional.This paper presents a comparative evaluation of five techniques for characterization of harmonic voltage distortion. Initially, are presented definitions, causes, effects and rules of this phenomenon. It are exposed the theoretical fundaments of techniques employed in the analysis, these being: Goertzel algorithm, Fourier Transform, Hartley Transform, Least Squares for Harmonicas and Levenberg-Marquard. To situate the reader in relation to the studies conducted on this topic, it is presented the State of the Art by using signals with known harmonic distortions and making use of the variation of characteristic parameters of the grid and measuring instruments in computer simulations, it was possible to classify the methods for accuracy in the characterization of the harmonic distortions, as well as identifying the parameters influence methods. The Levenberg-Marquard method achieved the best results in the assessments. However, it had the worst computational time
    • …
    corecore