27 research outputs found

    From line to dots: an improved computerised rod and frame system for testing subjective visual vertical and horizontal

    Get PDF
    Background Perception of subjective visual vertical (SVV) and horizontal (SVH) has traditionally been measured by rotating a mechanical rod either with or without a frame present. The computerised rod and frame (CRAF) system has previously only been used to measure SVV. We have expanded the use of this system by testing its feasibility to measure SVH. This was done by comparing two groups of subjects (n = 103) randomly assigned to be tested for SVV or SVH. Findings Preliminary results showed a higher than expected percentage of individuals with SVH errors < 0.5°. This was attributed to additional visual cues provided by the changing appearance of the rod as it approached the horizontal. A solution to this problem was sought by replacing the rod by two dots to mark its ends. In a second investigation 30 subjects were tested using both the "rod as line" and "rod as dots" presentation. Bland and Altman analysis showed no difference between the rod and dots presentations in the measurement of SVV, but confirmed a fixed error of -0.93° between rods and dots for SVH. Changing the rod from a line to dots in the computer system resulted in errors for both SVV and SVH that were comparable to previous studies using manual systems. Conclusions The computerized rod and frame system may be improved by replacement of the line with two dots. This reduces clues provided to the subject by the appearance of the rod on the screen

    Changes in rod and frame test scores recorded in schoolchildren during development--a longitudinal study.

    Get PDF
    The Rod and Frame Test has been used to assess the degree to which subjects rely on the visual frame of reference to perceive vertical (visual field dependence-independence perceptual style). Early investigations found children exhibited a wide range of alignment errors, which reduced as they matured. These studies used a mechanical Rod and Frame system, and presented only mean values of grouped data. The current study also considered changes in individual performance. Changes in rod alignment accuracy in 419 school children were measured using a computer-based Rod and Frame test. Each child was tested at school Grade 2 and retested in Grades 4 and 6. The results confirmed that children displayed a wide range of alignment errors, which decreased with age but did not reach the expected adult values. Although most children showed a decrease in frame dependency over the 4 years of the study, almost 20% had increased alignment errors suggesting that they were becoming more frame-dependent. Plots of individual variation (SD) against mean error allowed the sample to be divided into 4 groups; the majority with small errors and SDs; a group with small SDs, but alignments clustering around the frame angle of 18°; a group showing large errors in the opposite direction to the frame tilt; and a small number with large SDs whose alignment appeared to be random. The errors in the last 3 groups could largely be explained by alignment of the rod to different aspects of the frame. At corresponding ages females exhibited larger alignment errors than males although this did not reach statistical significance. This study confirms that children rely more heavily on the visual frame of reference for processing spatial orientation cues. Most become less frame-dependent as they mature, but there are considerable individual differences

    High-normal blood glucose levels may be associated with decreased spatial perception in young healthy adults.

    Get PDF
    The negative effects of high normal glucose on cognitive function were previously reported in euglycemic individuals of middle age and the elderly population. This study aimed at examining the effect of baseline blood glucose levels on spatial ability, specifically verticality perception on the computerized rod and frame test (CRFT) in young healthy adults. 63 healthy male medical students (age range from 18-23 years), of whom 30 were non-fasting outside the month of Ramadan and 33 fasting during Ramadan of the year 2016, were recruited in order to create varying degrees of glycemia during which verticality perception was carried out. Baseline blood glucose reading was obtained prior to commencing the CRFT test. Blood glucose levels at the time of testing decreased as the duration between the last meal and testing increased. A blood glucose range of 62-117 mg/dl was achieved among participants for this study. Linear regression analysis showed that blood glucose level at testing correlated positively with all alignment spatial error parameters, indicating a probable reduction of spatial perception ability with higher blood glucose levels. These results are consistent with other cognitive studies in older healthy humans and emphasize the critical impact of early glucose dys-homeostasis on cognitive function. They also indicate that elevated blood glucose may affect cognitive functioning outside of the usual complications of diabetes

    Symptom severity is associated with leftward lateralization upon contextual modulation of visual vertical in patients with schizophrenia

    Get PDF
    BackgroundContextual processing dysfunction in patients with schizophrenia (SCZ) is not uniform and task-dependent. In SCZ, studies on the rod and frame test (RFT), which evaluates contextual modulation of verticality perception, are sparse. A main study that utilized a two-alternative forced choice design for judging rod verticality reported equivalent strength of RFT contextual modulation in healthy controls and SCZ. The current study aims to uncover any potential differences in contextual modulation between controls and SCZ with an adjustment method on a computerized RFT.Materials and methodsA total of 17 healthy controls and 15 SCZ aligned an oriented rod to their perceived vertical with a computer mouse under four randomized frame presentations: absent frame, non-tilted (Frame0°), or tilted by 18 degrees leftward (Frame–18°) or rightward (Frame+18°). Rod deviation error was assigned a negative or positive value when aligned leftward or rightward, respectively, of 0°. Signed and absolute errors, the rod and frame effect (RFE), and intra-individual variability (inconsistency) were used for analysis.ResultsThere was no group difference in rod alignment errors or derived measures, except that SCZ displayed greater inconsistency in rod alignment, compared to controls. The negative symptom scale (PANSS-N) scores correlated positively with the variability measure and with unsigned Frame–18° error.ConclusionsOnly the variability measure was sensitive enough to distinguish between controls and SCZ. SCZ with more severe negative symptoms had larger variability in rod alignment, probably reflecting a state of indifference. The larger deviation errors only with a leftward tilted frame, as PANSS-N scores increased, may indicate a lateralized attentional abnormality that is correlated with severity of symptoms in SCZ

    Subjective visual vertical perception and sense of smell in Parkinson disease

    No full text

    Symptom severity is associated with leftward lateralization upon contextual modulation of visual vertical in patients with schizophrenia.

    Get PDF
    Background: Contextual processing dysfunction in patients with schizophrenia (SCZ) is not uniform and task-dependent. In SCZ, studies on the rod and frame test (RFT), which evaluates contextual modulation of verticality perception, are sparse. A main study that utilized a two-alternative forced choice design for judging rod verticality reported equivalent strength of RFT contextual modulation in healthy controls and SCZ. The current study aims to uncover any potential differences in contextual modulation between controls and SCZ with an adjustment method on a computerized RFT. Materials and methods: A total of 17 healthy controls and 15 SCZ aligned an oriented rod to their perceived vertical with a computer mouse under four randomized frame presentations: absent frame, non-tilted (Frame0°), or tilted by 18 degrees leftward (Frame-18°) or rightward (Frame+18°). Rod deviation error was assigned a negative or positive value when aligned leftward or rightward, respectively, of 0°. Signed and absolute errors, the rod and frame effect (RFE), and intra-individual variability (inconsistency) were used for analysis. Results: There was no group difference in rod alignment errors or derived measures, except that SCZ displayed greater inconsistency in rod alignment, compared to controls. The negative symptom scale (PANSS-N) scores correlated positively with the variability measure and with unsigned Frame-18° error. Conclusions: Only the variability measure was sensitive enough to distinguish between controls and SCZ. SCZ with more severe negative symptoms had larger variability in rod alignment, probably reflecting a state of indifference. The larger deviation errors only with a leftward tilted frame, as PANSS-N scores increased, may indicate a lateralized attentional abnormality that is correlated with severity of symptoms in SCZ

    Distribution of signed mean errors.

    No full text
    <p>A, Grade 2 (age 7–8 years); B, Grade 4 (age 9–10 years); C, Grade 6 (11–12 years). Open bars – counter clockwise frame tilt; filled bars – clockwise frame tilt. (n = 419 in all cases).</p

    Changes in Rod and Frame Test Scores Recorded in Schoolchildren during Development – A Longitudinal Study - Figure 1

    No full text
    <p>A–E. Frame alignment errors with frame tilt −18° (counter clockwise). Rod aligned to –A, vertical; B, lateral side; C, upper right corner; D, upper left corner; E, upper side. A mirror set of errors is generated with the frame tilt clockwise (+18°). F, shaded −9° sectors used to quantify the corresponding alignment strategies in A–E; unshaded–sectors classified as ‘other’. Sectors marked + frame tilt +18°; sectors marked – frame tilt −18°.</p

    Individual changes in absolute errors.

    No full text
    <p>Plot of the change in absolute error between Grade 2 and Grade 6 against the initial Grade 2 error for control subjects. The solid line indicates zero error, the dotted line indicates the frame angle (18°).</p
    corecore