35 research outputs found

    Computer-assisted and patient-specific 3-D planning and evaluation of a single-cut rotational osteotomy for complex long-bone deformities

    Get PDF
    Malunion after long bone fracture results in an incorrect position of the distal bone segment. This misalignment may lead to reduced function of the limb, early osteoarthritis and chronic pain. An established treatment option is a corrective osteotomy. For complex malunions, a single-cut rotational osteotomy is sometimes preferred in cases of angular deformity in three dimensions. However, planning and performing this type of osteotomy is relatively complex. This report describes a computer-assisted method for 3-D planning and realizing a single-cut rotational osteotomy with a patient-specific cutting guide for orienting the osteotomy and an angled jig for adjusting the rotation angle. The accuracy and reproducibility of the method is evaluated experimentally using plastic bones. In addition, complex rotational deformities are simulated by a computer to investigate the relation between deformity and correction parameters. The computed relation between deformity and correction parameters enables the surgeon to judge the feasibility of a single-cut rotational osteotomy. This appears possible for deformities combining axial misalignment with sufficient axial rotation. The proposed 3-D method of preoperative planning and transfer with a patient-specific cutting guide and angled jig renders the osteotomy procedure easily applicable, accurate, reproducible, and is a good alternative for complex and expensive navigation systems

    Flow of red blood cells suspensions through hyperbolic microcontractions

    Get PDF
    The present study uses a hyperbolic microchannel with a low aspect ratio (AR) to investigate how the red blood cells (RBCs) deform under conditions of both extensional and shear induced flows. The deformability is presented by the degree of the deformation index (DI) of the flowing RBCs throughout the microchannel at its centerline. A suitable image analysis technique is used for semi-automatic measurements of average DIs, velocity and strain rate of the RBCs travelling in the regions of interest. The results reveal a strong deformation of RBCs under both extensional and shear stress dominated flow conditions

    Navigation system for robot-assisted intra-articular lower-limb fracture surgery

    Get PDF
    Purpose In the surgical treatment for lower-leg intra-articular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard procedures use 2D radiographs to estimate the desired reduction position of bone fragments. However, optimal correction in a 3D space requires 3D imaging. This paper introduces a new navigation system that uses pre-operative planning based on 3D CT data and intra-operative 3D guidance to virtually reduce lower-limb intra-articular fractures. Physical reduction in the fractures is then performed by our robotic system based on the virtual reduction. Methods 3D models of bone fragments are segmented from CT scan. Fragments are pre-operatively visualized on the screen and virtually manipulated by the surgeon through a dedicated GUI to achieve the virtual reduction in the fracture. Intra-operatively, the actual position of the bone fragments is provided by an optical tracker enabling real-time 3D guidance. The motion commands for the robot connected to the bone fragment are generated, and the fracture physically reduced based on the surgeon’s virtual reduction. To test the system, four femur models were fractured to obtain four different distal femur fracture types. Each one of them was subsequently reduced 20 times by a surgeon using our system. Results The navigation system allowed an orthopaedic surgeon to virtually reduce the fracture with a maximum residual positioning error of 0.95±0.3mm (translational) and 1.4∘±0.5∘ (rotational). Correspondent physical reductions resulted in an accuracy of 1.03 ± 0.2 mm and 1.56∘±0.1∘, when the robot reduced the fracture. Conclusions Experimental outcome demonstrates the accuracy and effectiveness of the proposed navigation system, presenting a fracture reduction accuracy of about 1 mm and 1.5∘, and meeting the clinical requirements for distal femur fracture reduction procedures

    Measurement of functional microcirculatory geometry and velocity distributions using automated image analysis

    Get PDF
    This study describes a new method for analyzing microcirculatory videos. It introduces algorithms for quantitative assessment of vessel length, diameter, the functional microcirculatory density distribution and red blood-cell (RBC) velocity in individual vessels as well as its distribution. The technique was validated and compared to commercial software. The method was applied to the sublingual microcirculation in a healthy volunteer and in a patient during cardiac surgery. Analysis time was reduced from hours to minutes compared to previous methods requiring manual vessel identification. Vessel diameter was detected with high accuracy (>80%, d > 3 pixels). Capillary length was estimated within 5 pixels accuracy. Velocity estimation was very accurate (>95%) in the range [2.5, 1,000] pixels/s. RBC velocity was reduced by 70% during the first 10 s of cardiac luxation. The present method has been shown to be fast and accurate and provides increased insight into the functional properties of the microcirculation

    Image-Guided Surgical Robotic System for Percutaneous Reduction of Joint Fractures

    Get PDF
    Complex joint fractures often require an open surgical procedure, which is associated with extensive soft tissue damages and longer hospitalization and rehabilitation time. Percutaneous techniques can potentially mitigate these risks but their application to joint fractures is limited by the current sub-optimal 2D intra-operative imaging (fluoroscopy) and by the high forces involved in the fragment manipulation (due to the presence of soft tissue, e.g., muscles) which might result in fracture malreduction. Integration of robotic assistance and 3D image guidance can potentially overcome these issues. The authors propose an image-guided surgical robotic system for the percutaneous treatment of knee joint fractures, i.e., the robot-assisted fracture surgery (RAFS) system. It allows simultaneous manipulation of two bone fragments, safer robot-bone fixation system, and a traction performing robotic manipulator. This system has led to a novel clinical workflow and has been tested both in laboratory and in clinically relevant cadaveric trials. The RAFS system was tested on 9 cadaver specimens and was able to reduce 7 out of 9 distal femur fractures (T- and Y-shape 33-C1) with acceptable accuracy (≈1 mm, ≈5°), demonstrating its applicability to fix knee joint fractures. This study paved the way to develop novel technologies for percutaneous treatment of complex fractures including hip, ankle, and shoulder, thus representing a step toward minimally-invasive fracture surgeries

    Intra-operative fiducial-based CT/fluoroscope image registration framework for image-guided robot-assisted joint fracture surgery

    Get PDF
    Purpose Joint fractures must be accurately reduced minimising soft tissue damages to avoid negative surgical outcomes. To this regard, we have developed the RAFS surgical system, which allows the percutaneous reduction of intra-articular fractures and provides intra-operative real-time 3D image guidance to the surgeon. Earlier experiments showed the effectiveness of the RAFS system on phantoms, but also key issues which precluded its use in a clinical application. This work proposes a redesign of the RAFS’s navigation system overcoming the earlier version’s issues, aiming to move the RAFS system into a surgical environment. Methods The navigation system is improved through an image registration framework allowing the intra-operative registration between pre-operative CT images and intra-operative fluoroscopic images of a fractured bone using a custom-made fiducial marker. The objective of the registration is to estimate the relative pose between a bone fragment and an orthopaedic manipulation pin inserted into it intra-operatively. The actual pose of the bone fragment can be updated in real time using an optical tracker, enabling the image guidance. Results Experiments on phantom and cadavers demonstrated the accuracy and reliability of the registration framework, showing a reduction accuracy (sTRE) of about 0.88 ±0.2mm (phantom) and 1.15±0.8mm (cadavers). Four distal femur fractures were successfully reduced in cadaveric specimens using the improved navigation system and the RAFS system following the new clinical workflow (reduction error 1.2±0.3mm, 2±1∘). Conclusion Experiments showed the feasibility of the image registration framework. It was successfully integrated into the navigation system, allowing the use of the RAFS system in a realistic surgical application

    Syllectometry : the effect of aggregometer geometry in the assessment of red blood cell shape recovery and aggregation

    No full text
    Syllectometry is a measuring method that is commonly used to assess red blood cell (RBC) aggregability. In syllectometry, light is incident on a layer of whole blood initially exposed to shear flow. The backscattered light is measured after abruptly stopping the driving mechanism. The resultant time-dependent intensity plot is called the syllectogram. Parameters that quantify RBC aggregability are obtained by analyzing the syllectogram. As we will show in this paper, the upstroke in the initial part of the syllectogram contains the information for measurement of RBC-shape recovery in whole blood as well. To estimate RBC-shape recovery, we extended the existing two-exponential mathematical representation of the syllectogram by a third exponent that describes the upstroke. To investigate the feasibility of RBC-shape recovery measurement from the upstroke, we derived an analytical model of the flow decay that follows after abruptly stopping the driving mechanism. The model reveals that for large gaps the flow decay may interfere with the true RBC-shape recovery process. These theoretical findings were confirmed by velocity measurements in a Couette-type aggregometer. Syllectograms obtained using large gaps differ in many respects from those obtained using small gaps. As predicted by our model large gaps show a prolonged apparent shape-recovery time-constant. Moreover, a delayed intensity peak, a reduced upstroke of the intensity peak and a considerable increase of the half-life parameter are observed. The aggregation indices for large gaps are lower than for small gaps. This paper yields a better understanding of the velocity and shear-rate decay following upon abruptly stopping the driving mechanism. A better mathematical representation of the syllectogram and recommendations for a maximum gap width enables both RBC-shape recovery and aggregation measurements in whole blood using syllectometry
    corecore