    High Resistance Compensation Method for Surface Potential Measurement

    Get PDF
    The High Resistance Compensation Method (HRCM) was developed to measure the electrode potentials of high resistance electrodes. It is essentially similar to the classical Poggendorff compensation method, but instead of an ampere-meter, the pH-meter was introduced as an indicator of complete compensation. The method was applied to measurements of the electrode potentials of a single crystal rutile (TiO2) electrode. Electrode potentials were converted to surface potentials, and the dependency of the surface potential on pH in aqueous medium was determined

    Patohistološki nalazi kod žena podvrgnutih histeroskopskoj resekciji endometralnih polipa i mioma maternice

    Get PDF
    The aim of our study was to determine the prevalence of endometrial premalignant and malignant lesions in women undergoing hysteroscopy and to identify anthropologic factors related to the presence of malignancy. Data on 3470 women with submucosal myomas or endometrial polyps suspected on ultrasound were retrospectively analyzed. Hysteroscopy was performed in all these women in order to make a more precise diagnosis. Histologic analysis of endometrial samples obtained during hysteroscopy was used to confirm the diagnosis. Statistical analysis was performed using the SPSS 20.0.0 software. The mean age of study women was 49.1±13.3 years. The number of procedures performed due to the referral diagnosis of endometrial or submucosal myoma significantly increased over the 16-year study period. A significantly higher number of women had a benign histopathologic diagnosis. Histologic analysis revealed malignancy in 67 women. The youngest woman and oldest woman with malignant findings was aged 32 and 75, respectively. A significantly higher number of women with atypical hyperplasia and malignancy were in menopause. A comparable number of women with different histologic findings lived in urban and rural areas. There were a significantly larger proportion of widows among women with the histologic diagnosis of atypical hyperplasia or malignancy. The prevalence rate of malignancy in women having undergone hysteroscopy for polyps and myoma found by ultrasound was 1.93%. Postmenopausal status and older age were associated with an increased risk of malignancies, but premalignant changes and malignancies were also found in young and premenopausal women. Therefore, diagnostic hysteroscopy can be recommended in women of all age groups.Cilj ove studije bio je odrediti učestalost endometralnih premalignih i malignih lezija nakon histeroskopije te identificirati antropološke čimbenike povezane s malignitetom. Retrospektivno su analizirani podaci za 3470 žena s ultrazvučnom sumnjom na submukozni miom ili endometralni polip. Svim ženama je učinjena histeroskopija kako bi se dobila precizna dijagnoza. Uzorci iz endometrija dobiveni histeroskopijom poslani su na histološku analizu. Statistička analiza učinjena je primjenom programa SPSS 20.0.0. Prosječna dob žena u studiji bila je 49,1±13,3 godine. Broj zahvata zbog uputne dijagnoze endometralnog ili submukoznog mioma značajno je porastao u šesnaestogodišnjem razdoblju trajanja studije. Značajno veći broj žena imao je benignu histopatološku dijagnozu. Histološka analiza pokazala je malignitet u 67 žena. Najmlađa i najstarija žena s malignitetom imale su 32 i 75 godina. Značajno veći broj žena s atipičnom hiperplazijom i malignitetom bio je u menopauzi. Usporediv broj žena s različitim histološkim nalazima živio je u urbanim i ruralnim sredinama. Bio je značajnije viši udio udovica s dijagnozom atipične hiperplazije ili maligne bolesti. Učestalost malignosti kod žena kojima je učinjena histeroskopija zbog ultrazvučnog nalaza mioma ili polipa bila je 1,93%. Menopauza i starija dob bile su povezane s povišenim rizikom za zloćudne bolesti, ali premaligne i maligne promjene nađene su i kod mladih i premenopauzalnih žena. Stoga se dijagnostička histeroskopija preporuča u svim dobnim skupinama

    Routine coagulation testing in acute stroke

    Get PDF
    Uvod: Promjene u sustavu hemostaze mogu pridonijeti razvoju tromboembolijskih i hemoragijskih bolesti. Stoga je glavni cilj ovoga rada bio istražiti povezanost koagulacijskih pretraga koje se uobičajeno određuju po prijemu bolesnika s akutnim moždanim udarom (MU), njihov odnos s (pod)tipovima MU-a i ishodom nakon akutnoga MU-a. Materijali i metode: Retrospektivno su pregledani podatci o 262 pacijenta hospitaliziranih u razdoblju od siječnja do lipnja 2011. godine na Klinici za neurologiju Zavoda za cerebrovaskularne bolesti Kliničke bolnice „Sveti Duh” suspektnih na akutni moždani udar. Klasifikacija MU-a temeljena je na kliničkoj slici i nalazima neuroradiološke obrade, dok se ishod MU-a procjenjivao pomoću modificirane Rankinove ljestvice. Analizirani su rezultati koagulacijskih pretraga: PV-INR APTV, fibrinogena i D-dimera prilikom prijema pacijenata u bolnicu. Za sve pacijente izračunat je i omjer D-dimera i fibrinogena. Rezultati: U konačnu analizu uključena su 74 pacijenta, 67 s ishemijskim MU-om, od čega je u 22 pacijenta MU klasificiran kao lakunarni, a u 10 pacijenata kao hemoragijski. Nađena je umjerena, ali značajna pozitivna korelacija između vrijednosti D-dimera i modificirane Rankinove ljestvice (r = 0,470, CI% = 0,271-0,631; P < 0,0001). Tijekom hospitalizacije preminulo je 16 % bolesnika. Vrijednosti D dimera po primitku u bolnicu bile su statistički značajno više u bolesnika koji nisu preživjeli u odnosu na bolesnike koji su preživjeli MU (604 naspram 224 μg/L, P < 0,0001) kao i u bolesnika s dijagnosticiranim ishemijskim MU-om klasificiranim kao nelakunarni u odnosu na bolesnike s klasificiranim lakunarnim MU-om (294 naspram 206 μg /L. P = 0,02). Vrijednosti drugih koagulacijskih pretraga i omjera D-dimera i fibrinogena nisu se značajno razlikovale među ispitivanim grupama. Zaključak: Istraživanje je pokazalo da su povišene vrijednosti D-dimera povezane s lošijim ishodom nakon akutnoga MU-a te da njihovo određivanje po primitku može biti indikativno u smislu prognoze i ishodaIntroduction: Changes in haemostatic system could contribute to the development of thromboembolic and haemorrhagic disease. The main objective of this study was to explore the relationship between coagulation tests commonly used in the clinical settings on patient’s admission, stroke types and patient’s outcome. Patients and methods: Patients’ hospital charts and documentation were retrospectively reviewed for 262 patients admitted to the Stroke and Intensive Care Unit, Department of Neurology at “Sveti Duh” University Hospital, Zagreb, Croatia from January to June 2011 under the suspected diagnosis of acute stroke. Classification of stroke types was primarily based on clinical picture and imaging studies, whereas degree of patients’ disability and outcome was measured by modified Rankin Scale (mRS). Results of the coagulation test PT-INR, APTT, fibrinogen and D-dimer performed on admission were recorded. For all patients the D-dimer to fibrinogen ratio was also calculated. Results: Total of 74 patients were enrolled in the study, 67 with ischemic stroke whereby 22 of them were classified as patients with lacunar stroke and 10 as patients with haemorrhagic stroke. During hospitalisation 16% of patients did not survive. The median D-dimer value on admission was significantly higher in non-survivors than in survivors (604 vs. 224μg/L, P < 0.0001), as well as in patients with ischemic non-lacunar stroke in comparison to lacunar stroke (294 vs. 206 μg /L. P = 0.02). Although moderate, significant correlation was observed between elevated DD levels and mRS scale (r = 0.470, CI% = 0.271-0.631; P < 0.0001). Other coagulation parameters, as well as D-dimer/fibrinogen ratio, considered in the study did not show any significant difference between stroke type or survival. Conclusions: Our study revealed that increased DD levels in acute phase of the stroke are associated with stroke outcome and that their determination on admission could be indicative of prognosis and outcome

    Mogući utjecaji rata u Hrvatskoj (1990.-1995.) na epidemiologiju raka štitne žlijezde

    Get PDF
    A Thyroid Cancer Registry containing data of patients treated at our department during a 20-year period (1980-1999) has been established. The aim of the study was to analyze the possible effects of the 1990-1995 war in Croatia on the prevalence, type, and age and sex distribution of thyroid carcinoma. Three different 2-year periods were analyzed: distant prewar (1980-1981), immediate prewar (1989-1990) and postwar (1998-1999) period. There was no statistically significant difference in age at diagnosis and sex ratio among the three study periods. The incidence of follicular cancer was at the upper limit for countries with normal iodine uptake when the 20-year period was analyzed, however, in the 1980-1981 period follicular cancer accounted for 34.9%, and in 1998-99 for only 2.8% of all cases. Papillary cancer was diagnosed in less advanced stages than others. Five-year survival for papillary, follicular and anaplastic cancer was 100%, 100% and 0%, respectively. Analysis of the 2-year periods for all cancer types except anaplastic cancer showed the mean age at onset to be on a decrease. In the 1998-1999 period, papillary cancer was diagnosed in a more advanced stage. The number of follicular cancer cases decreased from 22 in 1980-1981 to 3 in 19891990 and 2 in 1998-1999. Analysis of the epidemiology of thyroid cancer in the pre- and post-Chernobyl period did not reveal any increase in the number of papillary cancer in younger patients. It was concluded that in the postwar period, patients presented in more advanced stages of the disease. However, the effects of war on the epidemiology of thyroid carcinoma and other malignant tumors should be further investigated.Na našoj Klinici uspostavljeni Registar raka štitne žlijezde sadrži podatke o svim bolesnicima obrađenim u Klinici u 20godišnjem razdoblju (1980.-1999.). Cilj ovoga istraživanja bio je utvrditi moguće učinke rata u Hrvatskoj na učestalost, histološki tip te spolnu i dobnu raspodjelu bolesnika sa zloćudnim tumorom štitne žlijezde. Analizom su obuhvaćena 3dvogodišnja razdoblja uključujući vrijeme znatno prije rata (1980.-1981.), neposredno prije rata (1989.-1990.) i nakon rata(1998.-1999.). Nije utvrđena statistički značajna razlika u starosti i spolnoj raspodjeli tumora između tri navedena razdoblja. Učestalost folikularnog raka bila je na gornjoj granici učestalosti za zemlje bez gušavosti, s tim da je u razdoblju 1980.-1981. bilo ukupno 34,9%, a u razdoblju 1998.-1999. samo 2,8% folikularnog karcinoma. Petogodišnje preživljenje bilo je 100%, 100% odnosno 0% za papilarni, folikularni i anaplastični rak. U uspoređivanim razdobljima prosječna starost bolesnika se snižavala, ali se rak dijagnosticirao u sve uznapredovalijem stadiju. Analiza populacije prije i nakon Černobila nije pokazala povećan broj mladih bolesnika s papilarnim karcinomom. Na temelju rezultata ovoga istraživanja zaključeno je da nije bilo povećanja učestalosti karcinoma štitnjače u poratnom razdoblju, međutim, bolesnici su se javljali s uznapredovalijim stadijima tumora. Ovaj i moguće druge učinke rata na karcinom štitnjače, kao i na druge zloćudne tumore, valja dalje istraživati

    Accurate Comparison of High-Ohm Resistances

    No full text
    Primarni elektromagnetski laboratorij (PEL), koji djeluje u sklopu Fakulteta elektrotehnike i računarstva u Zagrebu, kao glavnu zadaću ima pohranjivanje etalona četiriju osnovnih elektromagnetskih jedinica: volta, farada, oma i sekunde. Skupni etalon otpora FER i laboratorijski mjerni postupci za uspostavu i očuvanje sljedivosti postali su osnova za laboratorijsko umjeravanje otpora u vrhunskoj točnosti. Ograničenje postojećeg skupnog etalona na otpore do vrijednosti 100 MΩ potaknulo je razvoj novih mjernih postupaka i u visokoomskom području, s posebnim naglaskom na buduću izradu visokoomske etalonske baze do 1 TΩ. Na temelju provedene analize zahtjeva vrhunskog mjeriteljstva, u radu je predloen i ostvaren mjerni postupak za usporedbu visokoomskih otpora. Teorijska podloga problematike visokoomskih krugova, razvoj i izvedba mjernog sustava te rezultati obavljenih ispitivanja obuhvaćeni su sljedećim stranicama. Prilagodba mjernog postupka postojećem laboratorijskom instrumentariju te automatizacija računalom omogućili su njegovo brzo uključivanje u slijedni sustav PEL-a, a time su postavljeni temelji za uspostavu buduće visokoomske etalonske baze. U konačnici, cilj je magistarskog rada doprinos mjernim mogućnostima PEL-a koji svojim rezultatima ravnopravno sudjeluje u uspostavi međunarodno sljedivog mjernog sustava.A main task of Primary Electromagnetic Laboratory (PEL), within the Faculty of Electrical Engineering and Computing of the University of Zagreb, is maintenance of standards of four major electromagnetic units: volt, farad, ohm and second. The group of resistance standards and precise measurement procedures have become the basis of accurate laboratory resistance calibrations. The limitation of available resistance standards value up to 100 MΩ, has provoked the development of new methods in high-ohm measurement field, with emphasis on the future planned building of highohm resistance standard base up to 1 TΩ. After the analysis of high precision measurement conditions, a measurement procedure of high-ohm resistance comparison have been designed and realized. The demands of high-ohm measurement, development of appropriate apparatus and results are presented through the following pages. The adjustment of realized measurement procedure to available Laboratory instrumentation and its automation, have made possible fast merging in traceability chain of PEL, and thus the set up of future high-ohm resistance standards base has been initiated. Finally, the goal of this work is contribution to PEL measurement capabilities, and thus participating in establishment of international traceability measurement system

    Accurate Comparison of High-Ohm Resistances

    No full text
    Primarni elektromagnetski laboratorij (PEL), koji djeluje u sklopu Fakulteta elektrotehnike i računarstva u Zagrebu, kao glavnu zadaću ima pohranjivanje etalona četiriju osnovnih elektromagnetskih jedinica: volta, farada, oma i sekunde. Skupni etalon otpora FER i laboratorijski mjerni postupci za uspostavu i očuvanje sljedivosti postali su osnova za laboratorijsko umjeravanje otpora u vrhunskoj točnosti. Ograničenje postojećeg skupnog etalona na otpore do vrijednosti 100 MΩ potaknulo je razvoj novih mjernih postupaka i u visokoomskom području, s posebnim naglaskom na buduću izradu visokoomske etalonske baze do 1 TΩ. Na temelju provedene analize zahtjeva vrhunskog mjeriteljstva, u radu je predloen i ostvaren mjerni postupak za usporedbu visokoomskih otpora. Teorijska podloga problematike visokoomskih krugova, razvoj i izvedba mjernog sustava te rezultati obavljenih ispitivanja obuhvaćeni su sljedećim stranicama. Prilagodba mjernog postupka postojećem laboratorijskom instrumentariju te automatizacija računalom omogućili su njegovo brzo uključivanje u slijedni sustav PEL-a, a time su postavljeni temelji za uspostavu buduće visokoomske etalonske baze. U konačnici, cilj je magistarskog rada doprinos mjernim mogućnostima PEL-a koji svojim rezultatima ravnopravno sudjeluje u uspostavi međunarodno sljedivog mjernog sustava.A main task of Primary Electromagnetic Laboratory (PEL), within the Faculty of Electrical Engineering and Computing of the University of Zagreb, is maintenance of standards of four major electromagnetic units: volt, farad, ohm and second. The group of resistance standards and precise measurement procedures have become the basis of accurate laboratory resistance calibrations. The limitation of available resistance standards value up to 100 MΩ, has provoked the development of new methods in high-ohm measurement field, with emphasis on the future planned building of highohm resistance standard base up to 1 TΩ. After the analysis of high precision measurement conditions, a measurement procedure of high-ohm resistance comparison have been designed and realized. The demands of high-ohm measurement, development of appropriate apparatus and results are presented through the following pages. The adjustment of realized measurement procedure to available Laboratory instrumentation and its automation, have made possible fast merging in traceability chain of PEL, and thus the set up of future high-ohm resistance standards base has been initiated. Finally, the goal of this work is contribution to PEL measurement capabilities, and thus participating in establishment of international traceability measurement system

    Comparison of resistance and capacitance standards using Hamon divider and electronic differentiator

    No full text
    Preciznom usporedbom etalona otpora i etalona kapaciteta sljedivo se povezuju jedinice farad i om. U cilju uspostave R-C sljedivosti u Primarnom elektromagnetskom laboratoriju, razrađen je mjerni postupak usporedbe etalona otpora od 10 kΩ s etalonom kapaciteta od 100 pF. S obzirom da je referentni etalon otpora od 10 kΩ konstrukcijski predviđen za uporabu u mjernim krugovima istosmjerne struje, prijelaz na izmjenično mjerno područje osiguran je s pomoću posredničkog etalona otpora poznate frekvencijske ovisnosti. Posrednički etalon otpora izveden je u obliku Hamonova djelila, kojim se istodobno podiže usporedbena razina otpora, a sastoji se od deset ujednačenih otpora od 100 kΩ, prespajanjem kojih se iz paralelnog u serijski spoj postiže sljedivo povećanje razine otpora od 10 kΩ na 1 MΩ. Pri referentnoj mjernoj frekvenciji od 15,92 Hz impedancija etalona kapaciteta iznosi 100 MΩ, zbog čega je impedanciju Hamonova djelila u serijskom spoju moguće izravno usporediti s impedancijom etalonskog kapaciteta u omjeru 100:1. Mjerene veličine u ovom mjernom postupku jesu dva izmjenična napona jednakih nazivnih vrijednosti, pri čemu se jedan dobiva pomoćnim djelilom napona omjera dijeljenja 100:1, a drugi elektroničkim derivatorom, u krug kojega su spojeni etalon kapaciteta i posrednički etalon otpora u Hamonovoj izvedbi. Pritom uporaba digitalnih multimetara s 8½ znamenaka omogućuje izvedbu računalom upravljanog postupka za precizno mjerenje omjera izmjeničnih napona, iz kojeg se izravno očitava međusobna zavisnost uspoređivanih veličina: otpora i kapaciteta. Na temelju obavljenih mjerenja očekuje se daljnje pohranjivanje etalona dviju električkih veličina, otpora i kapaciteta, posebice u pogledu njihova povezivanja na razini točnosti boljoj od 0,5 milijuntinki.Transfer of traceability between units ohm and farad can be established with the method for highly accurate comparison of resistance and capacitance standards. The method for comparison of resistance standard of 10 kΩ and capacitance standard of 100 pF has been developed in the Primary electromagnetic laboratory, aiming to provide internal laboratory R-C traceability. The reference resistance standard of 10 kΩ is designed for dc current circuits, therefore an ac transfer standard with well-known frequency response should be implemented. For that purpose a Hamon divider has been constructed, which insures accurate transfer of resistance comparison to the higher values. The Hamon divider consists of ten well-balanced resistors with the nominal value of 100 kΩ, which connected in parallel or serially exhibits total resistance of 10 kΩ or 1 MΩ, respectively. The impedance of the Hamon divider in series connection can be directly compared with impedance of 100 pF capacitance standard with ratio 100:1, since the capacitive impedance at frequency of 15,92 Hz has exact value of 100 MΩ. Measuring quantities in this comparison method are two ac voltages with the same nominal value: one voltage established with auxiliary resistive divider with ratio of 100:1, and second voltage realized with electronic differentiator, which employs both capacitance standard of 100 pF and Hamon transfer standard of 1 MΩ. The relation between compared resistance and capacitance is derived from accurate determination of ac voltage ratio, measured by means of two programmable digital voltmeters with 8½ digits. On the basis of performed comparisons, a future maintenance of resistance and capacitance standards is being foreseen, with a relative uncertainty better than 0,5 ppm

    Accurate Comparison of High-Ohm Resistances

    No full text
    Primarni elektromagnetski laboratorij (PEL), koji djeluje u sklopu Fakulteta elektrotehnike i računarstva u Zagrebu, kao glavnu zadaću ima pohranjivanje etalona četiriju osnovnih elektromagnetskih jedinica: volta, farada, oma i sekunde. Skupni etalon otpora FER i laboratorijski mjerni postupci za uspostavu i očuvanje sljedivosti postali su osnova za laboratorijsko umjeravanje otpora u vrhunskoj točnosti. Ograničenje postojećeg skupnog etalona na otpore do vrijednosti 100 MΩ potaknulo je razvoj novih mjernih postupaka i u visokoomskom području, s posebnim naglaskom na buduću izradu visokoomske etalonske baze do 1 TΩ. Na temelju provedene analize zahtjeva vrhunskog mjeriteljstva, u radu je predloen i ostvaren mjerni postupak za usporedbu visokoomskih otpora. Teorijska podloga problematike visokoomskih krugova, razvoj i izvedba mjernog sustava te rezultati obavljenih ispitivanja obuhvaćeni su sljedećim stranicama. Prilagodba mjernog postupka postojećem laboratorijskom instrumentariju te automatizacija računalom omogućili su njegovo brzo uključivanje u slijedni sustav PEL-a, a time su postavljeni temelji za uspostavu buduće visokoomske etalonske baze. U konačnici, cilj je magistarskog rada doprinos mjernim mogućnostima PEL-a koji svojim rezultatima ravnopravno sudjeluje u uspostavi međunarodno sljedivog mjernog sustava.A main task of Primary Electromagnetic Laboratory (PEL), within the Faculty of Electrical Engineering and Computing of the University of Zagreb, is maintenance of standards of four major electromagnetic units: volt, farad, ohm and second. The group of resistance standards and precise measurement procedures have become the basis of accurate laboratory resistance calibrations. The limitation of available resistance standards value up to 100 MΩ, has provoked the development of new methods in high-ohm measurement field, with emphasis on the future planned building of highohm resistance standard base up to 1 TΩ. After the analysis of high precision measurement conditions, a measurement procedure of high-ohm resistance comparison have been designed and realized. The demands of high-ohm measurement, development of appropriate apparatus and results are presented through the following pages. The adjustment of realized measurement procedure to available Laboratory instrumentation and its automation, have made possible fast merging in traceability chain of PEL, and thus the set up of future high-ohm resistance standards base has been initiated. Finally, the goal of this work is contribution to PEL measurement capabilities, and thus participating in establishment of international traceability measurement system

    Comparison of resistance and capacitance standards using Hamon divider and electronic differentiator

    No full text
    Preciznom usporedbom etalona otpora i etalona kapaciteta sljedivo se povezuju jedinice farad i om. U cilju uspostave R-C sljedivosti u Primarnom elektromagnetskom laboratoriju, razrađen je mjerni postupak usporedbe etalona otpora od 10 kΩ s etalonom kapaciteta od 100 pF. S obzirom da je referentni etalon otpora od 10 kΩ konstrukcijski predviđen za uporabu u mjernim krugovima istosmjerne struje, prijelaz na izmjenično mjerno područje osiguran je s pomoću posredničkog etalona otpora poznate frekvencijske ovisnosti. Posrednički etalon otpora izveden je u obliku Hamonova djelila, kojim se istodobno podiže usporedbena razina otpora, a sastoji se od deset ujednačenih otpora od 100 kΩ, prespajanjem kojih se iz paralelnog u serijski spoj postiže sljedivo povećanje razine otpora od 10 kΩ na 1 MΩ. Pri referentnoj mjernoj frekvenciji od 15,92 Hz impedancija etalona kapaciteta iznosi 100 MΩ, zbog čega je impedanciju Hamonova djelila u serijskom spoju moguće izravno usporediti s impedancijom etalonskog kapaciteta u omjeru 100:1. Mjerene veličine u ovom mjernom postupku jesu dva izmjenična napona jednakih nazivnih vrijednosti, pri čemu se jedan dobiva pomoćnim djelilom napona omjera dijeljenja 100:1, a drugi elektroničkim derivatorom, u krug kojega su spojeni etalon kapaciteta i posrednički etalon otpora u Hamonovoj izvedbi. Pritom uporaba digitalnih multimetara s 8½ znamenaka omogućuje izvedbu računalom upravljanog postupka za precizno mjerenje omjera izmjeničnih napona, iz kojeg se izravno očitava međusobna zavisnost uspoređivanih veličina: otpora i kapaciteta. Na temelju obavljenih mjerenja očekuje se daljnje pohranjivanje etalona dviju električkih veličina, otpora i kapaciteta, posebice u pogledu njihova povezivanja na razini točnosti boljoj od 0,5 milijuntinki.Transfer of traceability between units ohm and farad can be established with the method for highly accurate comparison of resistance and capacitance standards. The method for comparison of resistance standard of 10 kΩ and capacitance standard of 100 pF has been developed in the Primary electromagnetic laboratory, aiming to provide internal laboratory R-C traceability. The reference resistance standard of 10 kΩ is designed for dc current circuits, therefore an ac transfer standard with well-known frequency response should be implemented. For that purpose a Hamon divider has been constructed, which insures accurate transfer of resistance comparison to the higher values. The Hamon divider consists of ten well-balanced resistors with the nominal value of 100 kΩ, which connected in parallel or serially exhibits total resistance of 10 kΩ or 1 MΩ, respectively. The impedance of the Hamon divider in series connection can be directly compared with impedance of 100 pF capacitance standard with ratio 100:1, since the capacitive impedance at frequency of 15,92 Hz has exact value of 100 MΩ. Measuring quantities in this comparison method are two ac voltages with the same nominal value: one voltage established with auxiliary resistive divider with ratio of 100:1, and second voltage realized with electronic differentiator, which employs both capacitance standard of 100 pF and Hamon transfer standard of 1 MΩ. The relation between compared resistance and capacitance is derived from accurate determination of ac voltage ratio, measured by means of two programmable digital voltmeters with 8½ digits. On the basis of performed comparisons, a future maintenance of resistance and capacitance standards is being foreseen, with a relative uncertainty better than 0,5 ppm