111 research outputs found

    Deep excursion beyond the proton dripline. I. Argon and chlorine isotope chains

    Get PDF
    The proton-unbound argon and chlorine isotopes have been studied by measuring trajectories of their decay-in-flight products by using a tracking technique with micro-strip detectors. The proton (1p) and two-proton (2p) emission processes have been detected in the measured angular correlations “heavy-fragment”+p and “heavy-fragment”+p+p, respectively. The ground states of the previously unknown isotopes 30Cl and 28Cl have been observed for the first time, providing the 1p separation energies Sp of −0.48(2) and −1.60(8) MeV, respectively. The relevant systematics of 1p and 2p separation energies have been studied theoretically in the core+p and core+p+p cluster models. The first-time observed excited states of 31Ar allow to infer the 2p-separation energy S2p of 6(34) keV for its ground state. The first-time observed state in 29Ar with S2p = −5.50(18) MeV can be identified either as a ground or an excited state according to different systematics.Helmholtz Association grant IK-RU-002Helmholtz International Center for FAIR HIC for FAIRRussian Science Foundation grant No. 17-12-01367Polish National Science Center Contract No. UMO- 2015/17/B/ST2/00581Polish Ministry of Science and Higher Education Grant No. 0079/DIA/2014/43, Grant DiamentowyHelmholtz- CAS Joint Research Group grant HCJRG-10

    Motor activity of paramecium | Dvigatel'naia aktivnost' parametsii.

    Get PDF
    A systemic study of the mechanisms of motor activity of paramecium was carried out. The movements of paramecium responding to various influences were photographed. The analysis of the data revealed the time dependences of the rate of movement, rate of rotation, and the radius and the pitch of the helix trajectory. Mathematical models of the membrane and a unit that transforms the calcium signal to programs of regulating the effectors were constructed. A system of equations for constructing the trajectory of movement was proposed. It is concluded that the biomolecular system that involves calmodulin, calmodulin-dependent ionic channels, adenylate cyclase, guanylate cyclase, phosphodiesterases, Ca(2+)-calmodulin, cAMP, cGMP-dependent protein kinases, and phosphoprotein phosphatases is capable of regulating motor reactions necessary for complex maneuvering of paramecium under various conditions

    Deep excursion beyond the proton dripline. II. Toward the limits of existence of nuclear structure

    Get PDF
    Prospects of experimental studies of argon and chlorine isotopes located far beyond the proton dripline are studied by using systematics and cluster models. The deviations from the widespread systematics observed in 28 , 29 Cl and 29 , 30 Ar have been theoretically substantiated, and analogous deviations have been predicted for the lighter chlorine and argon isotopes. The limits of nuclear structure existence are predicted for Ar and Cl isotopic chains, with 26 Ar and 25 Cl found to be the lightest sufficiently long-living nuclear systems. By simultaneous measurements of protons and γ rays following decays of such systems as well as their β -delayed emission, an interesting synergy effect may be achieved, which is demonstrated by the example of 30 Cl and 31 Ar ground-state studies. Such a synergy effect may be provided by the new EXPERT setup (EXotic Particle Emission and Radioactivity by Tracking) being operated inside the fragment separator and spectrometer facility at GSI, Darmstadt.Helmholtz Association de Alemania. IK-RU-002Russian Science Foundation. 17-12-01367Polish National Science Center. UMO2015/17/B/ST2/00581Polish Ministry of Science and Higher Education. 0079/DIA/2014/43Helmholtz- CAS Joint Research Group de Alemania. HCJRG-108Ministerio de Educación y Ciencia, España. FPA2016-77689-C2-1-RMinistry of Education, Youth and Sports de la República Checa. LTT17003 y LM201504

    Motor activity of paramecium

    Get PDF
    A systemic study of the mechanisms of motor activity of paramecium was carried out. The movements of paramecium responding to various influences were photographed. The analysis of the data revealed the time dependences of the rate of movement, rate of rotation, and the radius and the pitch of the helix trajectory. Mathematical models of the membrane and a unit that transforms the calcium signal to programs of regulating the effectors were constructed. A system of equations for constructing the trajectory of movement was proposed. It is concluded that the biomolecular system that involves calmodulin, calmodulin-dependent ionic channels, adenylate cyclase, guanylate cyclase, phosphodiesterases, Ca2+-calmodulin, cAMP, cGMP-dependent protein kinases, and phosphoprotein phosphatases is capable of regulating motor reactions necessary for complex maneuvering of paramecium under various conditions

    SCREENING OF RICE ACCESSIONS FOR GREENBUG RESISTANCE

    Get PDF
    During recent years the harmfulness of greenbug for rice crops has significantly increased. Laboratory experiments were conducted to study insect resistance of 200 accessions from the collection of the Donskoy Agrarian Scientific Center. The overwhelming majority of the studied forms were heterogeneous in their resistance. Twelve forms (5.5%) with the resistance score 2.2-3.0 were identified. The accessions NSH-1 (Hungary), ‘Musa Karem’ (Iran) and Zlatyi х Strelets (Russia) do not contain susceptible components and can be recommended as sources of aphid resistance for breeding rice varieties

    Superconducting and magnetic properties of a new EuAsFeO0.85F0.15 superconductor

    Full text link
    Polycrystalline samples of a new superconducting EuAsFeO0.85F0.15 compound with critical temperature Tc=11K were prepared by solid state synthesis. Its electric and magnetic properties have been investigated in magnetic fields from 0.1 to 140000 Oe. Critical magnetic fields Hc1, and Hc2 were measured and hence the magnetic penetration depths and the coherence length have been estimated. The temperature dependence Hc2 (T) exhibits clear hyperbolic - type behavior starting with the lowest fields. The data derived were used to estimate probable high Tc and Hc2 in compounds doped with rare-earths having small atomic radii.Comment: 12 pages, 10 figures, 13 reference

    Precision of the PET activity range during irradiation with <sup>10</sup>C, <sup>11</sup>C, and <sup>12</sup>C beams

    Get PDF
    Objective. Beams of stable ions have been a well-established tool for radiotherapy for many decades. In the case of ion beam therapy with stable 12C ions, the positron emitters 10,11C are produced via projectile and target fragmentation, and their decays enable visualization of the beam via positron emission tomography (PET). However, the PET activity peak matches the Bragg peak only roughly and PET counting statistics is low. These issues can be mitigated by using a short-lived positron emitter as a therapeutic beam. Approach. An experiment studying the precision of the measurement of ranges of positron-emitting carbon isotopes by means of PET has been performed at the FRS fragment-separator facility of GSI Helmholtzzentrum für Schwerionenforschung GmbH, Germany. The PET scanner used in the experiment is a dual-panel version of a Siemens Biograph mCT PET scanner. Main results. High-quality in-beam PET images and activity distributions have been measured from the in-flight produced positron emitting isotopes 11C and 10C implanted into homogeneous PMMA phantoms. Taking advantage of the high statistics obtained in this experiment, we investigated the time evolution of the uncertainty of the range determined by means of PET during the course of irradiation, and show that the uncertainty improves with the inverse square root of the number of PET counts. The uncertainty is thus fully determined by the PET counting statistics. During the delivery of 1.6 × 107 ions in 4 spills for a total duration of 19.2 s, the PET activity range uncertainty for 10C, 11C and 12C is 0.04 mm, 0.7 mm and 1.3 mm, respectively. The gain in precision related to the PET counting statistics is thus much larger when going from 11C to 10C than when going from 12C to 11C. The much better precision for 10C is due to its much shorter half-life, which, contrary to the case of 11C, also enables to include the in-spill data in the image formation. Significance. Our results can be used to estimate the contribution from PET counting statistics to the precision of range determination in a particular carbon therapy situation, taking into account the irradiation scenario, the required dose and the PET scanner characteristics.</p
    corecore