28 research outputs found

    Viral Hepatitis and Rapid Diagnostic Test Based Screening for HBsAg in HIV-infected Patients in Rural Tanzania.

    Get PDF
    \ud \ud Co-infection with hepatitis B virus (HBV) is highly prevalent in people living with HIV in Sub-Saharan Africa. Screening for HBV surface antigen (HBsAg) before initiation of combination antiretroviral therapy (cART) is recommended. However, it is not part of diagnostic routines in HIV programs in many resource-limited countries although patients could benefit from optimized antiretroviral therapy covering both infections. Screening could be facilitated by rapid diagnostic tests for HBsAg. Operating experience with these point of care devices in HIV-positive patients in Sub-Saharan Africa is largely lacking. We determined the prevalence of HBV and Hepatitis C virus (HCV) infection as well as the diagnostic accuracy of the rapid test device Determine HBsAg in an HIV cohort in rural Tanzania. Prospectively collected blood samples from adult, HIV-1 positive and antiretroviral treatment-naïve patients in the Kilombero and Ulanga antiretroviral cohort (KIULARCO) in rural Tanzania were analyzed at the point of care with Determine HBsAg, a reference HBsAg EIA and an anti-HCV EIA. Samples of 272 patients were included. Median age was 38 years (interquartile range [IQR] 32-47), 169/272 (63%) subjects were females and median CD4+ count was 250 cells/”L (IQR 97-439). HBsAg was detected in 25/272 (9.2%, 95% confidence interval [CI] 6.2-13.0%) subjects. Of these, 7/25 (28%) were positive for HBeAg. Sensitivity of Determine HBsAg was rated at 96% (95% CI 82.8-99.6%) and specificity at 100% (95% CI, 98.9-100%). Antibodies to HCV (anti-HCV) were found in 10/272 (3.7%, 95% CI 2.0-6.4%) of patients. This study reports a high prevalence of HBV in HIV-positive patients in a rural Tanzanian setting. The rapid diagnostic test Determine HBsAg is an accurate assay for screening for HBsAg in HIV-1 infected patients at the point of care and may further help to guide cART in Sub-Saharan Africa

    Simulation modeling for stratified breast cancer screening : a systematic review of cost and quality of life assumptions

    Get PDF
    BACKGROUND: The economic evaluation of stratified breast cancer screening gains momentum, but produces also very diverse results. Systematic reviews so far focused on modeling techniques and epidemiologic assumptions. However, cost and utility parameters received only little attention. This systematic review assesses simulation models for stratified breast cancer screening based on their cost and utility parameters in each phase of breast cancer screening and care. METHODS: A literature review was conducted to compare economic evaluations with simulation models of personalized breast cancer screening. Study quality was assessed using reporting guidelines. Cost and utility inputs were extracted, standardized and structured using a care delivery framework. Studies were then clustered according to their study aim and parameters were compared within the clusters. RESULTS: Eighteen studies were identified within three study clusters. Reporting quality was very diverse in all three clusters. Only two studies in cluster 1, four studies in cluster 2 and one study in cluster 3 scored high in the quality appraisal. In addition to the quality appraisal, this review assessed if the simulation models were consistent in integrating all relevant phases of care, if utility parameters were consistent and methodological sound and if cost were compatible and consistent in the actual parameters used for screening, diagnostic work up and treatment. Of 18 studies, only three studies did not show signs of potential bias. CONCLUSION: This systematic review shows that a closer look into the cost and utility parameter can help to identify potential bias. Future simulation models should focus on integrating all relevant phases of care, using methodologically sound utility parameters and avoiding inconsistent cost parameters

    Etoricoxib - preemptive and postoperative analgesia (EPPA) in patients with laparotomy or thoracotomy - design and protocols

    Get PDF
    <p>Abstract</p> <p>Background and Objective</p> <p>Our objective was to report on the design and essentials of the <it>Etoricoxib </it>protocol<it>- Preemptive and Postoperative Analgesia (EPPA) </it>Trial, investigating whether preemptive analgesia with cox-2 inhibitors is more efficacious than placebo in patients who receive either laparotomy or thoracotomy.</p> <p>Design and Methods</p> <p>The study is a 2 × 2 factorial armed, double blinded, bicentric, randomised placebo-controlled trial comparing (a) etoricoxib and (b) placebo in a pre- and postoperative setting. The total observation period is 6 months. According to a power analysis, 120 patients scheduled for abdominal or thoracic surgery will randomly be allocated to either the preemptive or the postoperative treatment group. These two groups are each divided into two arms. Preemptive group patients receive etoricoxib prior to surgery and either etoricoxib again or placebo postoperatively. Postoperative group patients receive placebo prior to surgery and either placebo again or etoricoxib after surgery (2 × 2 factorial study design). The Main Outcome Measure is the cumulative use of morphine within the first 48 hours after surgery (measured by patient controlled analgesia PCA). Secondary outcome parameters include a broad range of tests including sensoric perception and genetic polymorphisms.</p> <p>Discussion</p> <p>The results of this study will provide information on the analgesic effectiveness of etoricoxib in preemptive analgesia and will give hints on possible preventive effects of persistent pain.</p> <p>Trial registration</p> <p>NCT00716833</p

    The 2014 ALMA Long Baseline Campaign: An Overview

    Get PDF
    A major goal of the Atacama Large Millimeter/submillimeter Array (ALMA) is to make accurate images with resolutions of tens of milliarcseconds, which at submillimeter (submm) wavelengths requires baselines up to ~15 km. To develop and test this capability, a Long Baseline Campaign (LBC) was carried out from September to late November 2014, culminating in end-to-end observations, calibrations, and imaging of selected Science Verification (SV) targets. This paper presents an overview of the campaign and its main results, including an investigation of the short-term coherence properties and systematic phase errors over the long baselines at the ALMA site, a summary of the SV targets and observations, and recommendations for science observing strategies at long baselines. Deep ALMA images of the quasar 3C138 at 97 and 241 GHz are also compared to VLA 43 GHz results, demonstrating an agreement at a level of a few percent. As a result of the extensive program of LBC testing, the highly successful SV imaging at long baselines achieved angular resolutions as fine as 19 mas at ~350 GHz. Observing with ALMA on baselines of up to 15 km is now possible, and opens up new parameter space for submm astronomy

    Neovascular age-related macular degeneration: A review of findings from the real-world Fight Retinal Blindness! registry

    Get PDF
    The use of vascular endothelial growth factor (VEGF) inhibitors has revolutionised the treatment of neovascular age-related macular degeneration (nAMD) since the pivotal Phase III studies demonstrated their efficacy more than 10 years ago. The Fight Retinal Blindness! project was developed to track the treatment outcomes of patients with nAMD in real-world practice. Data from this registry have been used to answer several clinically relevant questions related to the treatment of nAMD including the effect of under-treatment, the comparative effectiveness of different anti-vascular endothelial growth factor agents, long-term treatment outcomes, identifying optimal treatment regimens and the rate and outcomes of rare adverse events. Observational studies are a valuable complement to the shortcomings of clinical trials and a combination of data from real-world settings and clinical trials are necessary to provide evidence on how to achieve the best outcomes for individual patients with nAMD
    corecore