13 research outputs found

    IT-supported integrated care pathways for diabetes: A compilation and review of good practices

    Get PDF
    Introduction: Integrated Care Pathways (ICPs) are a method for the mutual decision-making and organization of care for a well-defined group of patients during a well-defined period. The aim of a care pathway is to enhance the quality of care by improving patient outcomes, promoting patient safety, increasing patient satisfaction, and optimizing the use of resources. To describe this concept, different names are used, e.g. care pathways and integrated care pathways. Modern information technologies (IT) can support ICPs by enabling patient empowerment, better management, and the monitoring of care provided by multidisciplinary teams. This study analyses ICPs across Europe, identifying commonalities and success factors to establish good practices for IT-supported ICPs in diabetes care. Methods: A mixed-method approach was applied, combining desk research on 24 projects from the European Innovation Partnership on Active and Healthy Ageing (EIP on AHA) with follow-up interviews of project participants, and a non-systematic literature review. We applied a Delphi technique to select process and outcome indicators, derived from different literature sources which were compiled and applied for the identification of successful good practices. Results: Desk research identified sixteen projects featuring IT-supported ICPs, mostly derived from the EIP on AHA, as good practices based on our criteria. Follow-up interviews were then conducted with representatives from 9 of the 16 projects to gather information not publicly available and understand how these projects were meeting the identified criteria. In parallel, the non-systematic literature review of 434 PubMed search results revealed a total of eight relevant projects. On the basis of the selected EIP on AHA project data and non-systematic literature review, no commonalities with regard to defined process or outcome indicators could be identified through our approach. Conversely, the research produced a heterogeneous picture in all aspects of the projects’ indicators. Data from desk research and follow-up interviews partly lacked information on outcome and performance, which limited the comparison between practices. Conclusion: Applying a comprehensive set of indicators in a multi-method approach to assess the projects included in this research study did not reveal any obvious commonalities which might serve as a blueprint for future IT-supported ICP projects. Instead, an unexpected high degree of heterogeneity was observed, that may reflect diverse local implementation requirements e.g. specificities of the local healthcare system, local regulations, or preexisting structures used for the project setup. Improving the definition of and reporting on project outcomes could help advance research on and implementation of effective integrated care solutions for chronic disease management across Europe

    ARIA 2016: Care pathways implementing emerging technologies for predictive medicine in rhinitis and asthma across the life cycle

    Get PDF
    The Allergic Rhinitis and its Impact on Asthma (ARIA) initiative commenced during a World Health Organization workshop in 1999. The initial goals were (1) to propose a new allergic rhinitis classification, (2) to promote the concept of multi-morbidity in asthma a

    Critical Factors in ‘Livings Labs’ for New Health Concepts and Medical Technology

    No full text
    Living labs are a relatively new instrument in enhancing open innovation. They are practical environments for innovation aiming at a better mix and match between stakeholders for co-development and reduction of time-to-market of innovations through early involvement of user groups. Living lab settings range from delimited environments for co-creation and development, like a city quarter, a hospital and university campus, to local and regional networks and platforms of open innovation. Participants in living labs are typically universities, research institutes, user groups, small and large firms, non-profit institutions and local/regional authorities. Accordingly, living labs find themselves in a dynamic multi-actor situation that needs to be dealt with, both in their design and management. The focus of this paper is on living labs for health care innovations. Health care is under pressure as a consequence of the aging population, and fast increasing population with chronic conditions and shortage of resource. The paper identifies critical factors in the design of medical living labs using the literature and an analysis of five case studies of such living labs.Valorisation Centre and YES DelftMechanical, Maritime and Materials Engineerin

    Developing a Health and Wellbeing Platform in a Living Lab Setting: An Action Design Research Study

    Get PDF
    The world’s population is rapidly aging, which affects healthcare budgets, resources, pensions and social security systems. Although most older adults prefer to live independently in their own home as long as possible, smart living solutions to support elderly people at home did not reach mass adoption, yet. To support people age-in-place a Living Lab is established in one of the metropolitan areas in the Netherlands. The main goal of the Living Lab is to develop an online health and wellbeing platform that matches service providers, caretakers and users and to implement that platform in one particular city district. In this paper we describe the narrative of the action design research process that will give researchers insight how to deal with complex multistakeholder design projects as well as cooperation issues to develop an artifact in a real-life setting.Engineering, Systems and ServicesTechnology, Policy and Managemen

    A comparison of hallux valgus angles assessed with computerised plantar pressure measurements, clinical examination and radiography in patients with diabetes

    No full text
    Background Hallux valgus deformity is a common musculoskeletal foot disorder with a prevalence of 3.5% in adolescents to 35.7% in adults aged over 65 years. Radiographic measurements of hallux valgus angles (HVA) are considered to be the most reproducible and accurate assessment of HVA. However, in European countries, many podiatrists do not have direct access to radiographic facilities. Therefore, alternative measurements are desired. Such measurements are computerised plantar pressure measurement and clinical goniometry. The purpose of this study was to establish the agreement of these techniques and radiographic assessments. Methods HVA was determined in one hundred and eighty six participants suffering from diabetes. Radiographic measurements of HVA were performed with standardised static weight bearing dorsoplantar foot radiographs. The clinical goniometry for HVA was measured with a universal goniometer. Computerised plantar pressure measurement for HVA was executed with the EMED SF-4® pressure platform and Novel-Ortho-Geometry software. The intra-class correlation coefficients (ICC) and levels of agreement were analysed using Bland & Altman plots. Results Comparison of radiographic measurements to clinical goniometry for HVA showed an intraclass correlation coefficient (ICC) of 0.81 (95% confidence interval, 0.76 to 0.86; p<0.001). Radiographic measurement versus computerised plantar pressure measurement showed an ICC of 0.59 (95% confidence interval, 0.49 to 0.68; p<0.001). In addition, clinical goniometry versus computerised plantar pressure measurement showed an ICC of 0.77 (95% confidence interval, 0.70 to 0.82; p<0.001). The systematic difference of the computerised plantar pressure measurement compared with radiographic measurement and clinical goniometry was 7.0 degrees (SD 6.8) and 5.2 degrees (SD 5.0), respectively. The systemic difference of radiographic measurements compared with clinical goniometry was 1.8 degrees (SD 5.0). Conclusions The agreement of computerised plantar pressure measurement and clinical goniometry for HVA compared to radiographic measurement of HVA is unsatisfactory. Radiographic measurements of HVA and clinical goniometry for HVA yield better agreement compared to radiographic measurements and computerised plantar pressure measurement. The traditional radiographic measurement techniques are strongly recommended for the assessment of HVAMan-machine InteractionElectrical Engineering, Mathematics and Computer Scienc

    Regional plantar foot pressure distributions on high-heeled shoes-shank curve effects

    No full text
    Forefoot pain is common in high-heeled shoe wearers due to the high pressure caused by the center of body mass moving forward and the increased arch height with heel elevation. Sufficient arch support could reduce the high pressure over forefoot. However, too much arch support could lead to abnormal foot alignment and pain over midfoot. Little information is reported on the relationship among plantar arch height, shank curve design and plantar pressure. This study aimed at quantifying the plantar arch height changes at different heel heights and investigating the effect of shank curve on plantar pressure distribution. The plantar arch height increased to (7.6±1.3)mm at heel height of 75 mm. The Chinese standard suggests the depth of last should be 8.5mm for heel height of 75 mm. When a shank curve with higher depth of last (11 mm) was used, the peak pressure over forefoot further decreased in midstance phase, which might ease the forefoot problems, while the peak pressure over midfoot increased but not exceeded the discomfort pressure thresholds. To achieve a more ideal pressure distribution in high-heeled shoes, a higher than expected depth of last would be suggested that would not cause discomfort over midfoot

    Validation of the MASK-rhinitis visual analogue scale on smartphone screens to assess allergic rhinitis control

    No full text
    Background: Visual Analogue Scale (VAS) is a validated tool to assess control in allergic rhinitis patients. Objective: The aim of this study was to validate the use of VAS in the MASK-rhinitis (MACVIA-ARIA Sentinel NetworK for allergic rhinitis) app (Allergy Diary) on smartphones screens to evaluate allergic rhinitis symptoms and disease control. Methods: Each user filled 4 different VAS measuring overall, nasal, ocular, and asthma symptoms at least once. Following COSMIN guidelines, we evaluated internal consistency, (Cronbach&apos;s alpha coefficient and test-retest), reliability (intraclass correlation coefficients), sensitivity, and acceptability of the MASK-Rhinitis VAS. Results: Between 1 August 2015 and 31 July 2016, the app was used 14 612 times in 15 countries. A total of 1225 users used it more than once, during the evaluated period. The tool resulted to be statistically satisfactory, showing excellent internal consistency (Cronbach&apos;s test &gt; 0.84, test-retest &gt; 0.7), reliability (&gt;0.9), and acceptability. In addition, the tool had a good sensitivity when users (n = 521) answered the VAS twice in less than 3 hours. Conclusions and Clinical Relevance: The MASK-rhinitis VAS is a reliable and valid tool to assess allergic control on smartphone screens, at the population level. © 2017 John Wiley &amp; Sons Lt
    corecore