    Multicentre evaluation of the Boehringer Mannheim / Hitachi 911 Analysis System

    Get PDF
    The analytical performance and practicability of the Boehringer Mannheim (BM)/mtaci 91 analysis system have been assessed in a multicentre evaluation, which involved six laboratories from European countries. Analytes commonly used in classical clinical chemistry were tested in a core programme, which mainlyfollowed lhe ECCLS guidelines. In addition, a satellite programme covered other analytes, such as proteins, drugs and urine analytes. In total, the study comprised more than 100 000 data items collected over a three-month period. The evaluation was supported with 'Computer Aided Evaluation' (CAEv) and telecommunications. Acceptance criteria for the results were established at the beginning ofthe study. Nearly all ofthe analytes met the imprecision limits.' within-run imprecision (as CVs) was 2l/ofor enzyme and substrate assays, l%for ISE methods and 5l/o for immunoassays; between-day imprecision was 3l/ofor enzyme and substrate assays, 2o//o for ISE methods and 10% for immunoassays

    Overcoming challenges regarding reference materials and regulations that influence global standardization of medical laboratory testing results

    Get PDF
    Background: Standardized results for laboratory tests are particularly important when their interpretation depends on fixed medical practice guidelines or common reference intervals. The medical laboratory community has developed a roadmap for an infrastructure to achieve standardized test results described in the International Organization for Standardization standard 17511:2020 In vitro diagnostic medical devices - Requirements for establishing metrological traceability of values assigned to calibrators, trueness control materials and human samples. Among the challenges to implementing metrological traceability are the availability of fit-for-purpose matrix-based certified reference materials (CRMs) and requirements for regulatory review that differ among countries. A workshop in December 2021 focused on these two challenges and developed recommendations for improved practices. Discussion: The participants agreed that prioritization of measurands for standardization should be based on their impact on medical decisions in a clinical pathway. Ensuring that matrix-based CRMs are globally available for more measurands will enable fit-for-purpose calibration hierarchies for more laboratory tests. Regulation of laboratory tests is important to ensure safety and effectiveness for the populations served. Because regulations are country or region specific, manufacturers must submit recalibration changes intended to standardize results for regulatory review to all areas in which a measuring system is marketed. Recommendations: A standardization initiative requires collaboration and planning among all interested stakeholders. Global collaboration should be further developed for prioritization of measurands for standardization, and for coordinating the production and supply of CRMs worldwide. More uniform regulatory submission requirements are desirable when recalibration is implemented to achieve internationally standardized results.Afdeling Klinische Chemie en Laboratoriumgeneeskunde (AKCL

    Investigation of 2 Models to Set and Evaluate Quality Targets for Hb A1c: Biological Variation and Sigma-Metrics

    Get PDF
    BACKGROUND: A major objective of the IFCC Task Force on Implementation of HbA1c Standardization is to develop a model to define quality targets for glycated hemoglobin (Hb A1c). METHODS: Two generic models, biological variation and sigma-metrics, are investigated. We selected variables in the models for Hb A1c and used data of external quality assurance/proficiency testing programs to evaluate the suitability of the models to set and evaluate quality targets within and between laboratories. RESULTS: In the biological variation model, 48% of individual laboratories and none of the 26 instrument groups met the minimum performance criterion. In the sigma-metrics model, with a total allowable error (TAE) set at 5 mmol/mol (0.46% NGSP), 77% of the individual laboratories and 12 of 26 instrument groups met the 2σ criterion. CONCLUSIONS: The biological variation and sigma-metrics models were demonstrated to be suitable for setting and evaluating quality targets within and between laboratories. The sigma-metrics model is more flexible, as both the TAE and the risk of failure can be adjusted to the situation—for example, requirements related to diagnosis/monitoring or international authorities. With the aim of reaching (inter)national consensus on advice regarding quality targets for Hb A1c, the Task Force suggests the sigma-metrics model as the model of choice, with default values of 5 mmol/mol (0.46%) for TAE and risk levels of 2σ and 4σ for routine laboratories and laboratories performing clinical trials, respectively. These goals should serve as a starting point for discussion with international stakeholders in the field of diabetes

    A novel human skin chamber model to study wound infection ex vivo

    Get PDF
    Wound infections with multi-drug resistant bacteria increase morbidity and mortality and have considerable socioeconomic impact. They can lead to impaired wound healing, resulting in rising treatment costs. The aim of this study was to investigate an ex vivo human wound infection model. Human full-thickness skin from the operating room (OR) was placed into the Bo-Drum® and cultivated for 7 days in an air–liquid interphase. On day 8, the skin was inoculated with either (1) Pseudomonas aeruginosa, (2) Staphylococcus aureus (105 CFU, n = 3) or (3) carrier control. 1, 3 and 7 days after inoculation colony forming units in the tissue/media were determined and cytokine expression was quantified. A reliable and reproducible wound infection could be established for 7 days. At this timepoint, 1.8 × 108 CFU/g tissue of P. aeruginosa and 2 × 107 CFU/g tissue of S. aureus were detected. Immunohistochemical analysis demonstrated bacterial infection and epidermolysis in infected skin. RT-PCR analysis exhibited a significant induction of proinflammatory cytokines after infection. The BO-drum® is a robust, easy-to-use, sterilizable and reusable ex vivo full-skin culture system. For investigation of wound infection, treatment and healing, the BO-drum® presents a convenient model and may help to standardize wound research

    Lipids and carotid plaque in the Northern Manhattan Study (NOMAS)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Lipids, particularly low-density (LDL) and high-density (HDL) lipoproteins, are associated with increased risk of stroke and cardiovascular disease, probably due to atherosclerosis. The objective of this cross-sectional analysis was to investigate the relation between blood lipids and carotid plaque.</p> <p>Methods</p> <p>As part of a prospective population-based study to determine the incidence and risk factors of stroke in a multiethnic population, we evaluated 1804 participants with lipid measurements and B-mode ultrasound of carotid arteries (mean age 69 +/- 10 years; 40% men; 51% Hispanic, 26% black, 23% white). The association between lipid parameters and carotid plaque was analyzed by multiple logistic regression.</p> <p>Results</p> <p>Plaque was present in 61% of participants. Mean total cholesterol was 202 +/- 41 mg/dl. After controlling for other lipid parameters, demographics, and risk factors, the only cholesterol subfraction associated with carotid plaque was LDL (OR per standard deviation (SD) = 1.14, 95% CI 1.02-1.27). Neither HDL nor triglycerides independently predicted carotid plaque. Apolipoprotein B (ApoB) was also associated with risk of plaque (OR per SD = 1.29, 95% CI 1.03-1.60). Apolipoprotein A-I (apoA-1) was associated with a decrease in multiple plaques (OR per SD = 0.76, 95% CI 0.60-0.97), while lipoprotein a was associated with an increased risk of multiple plaques (OR per SD = 1.31, 95% CI 1.03-1.66). ApoB:ApoA-I had the strongest relation with carotid plaque (OR per SD = 1.35, 95% CI 1.08-1.69).</p> <p>Conclusions</p> <p>Among the common lipid parameters, LDL has the strongest relation with carotid plaque. Other lipid precursor proteins such as ApoB and ApoA-I may be stronger predictors of subclinical atherosclerosis, however, and better targets for treatment to reduce plaque formation and risk of cerebrovascular disease.</p
    corecore