596 research outputs found
Analysis of testbed airborne multispectral scanner data from Superflux II
A test bed aircraft multispectral scanner (TBAMS) was flown during the James Shelf, Plume Scan, and Chesapeake Bay missions as part of the Superflux 2 experiment. Excellent correlations were obtained between water sample measurements of chlorophyll and sediment and TBAMS radiance data. The three-band algorithms used were insensitive to aircraft altitude and varying atmospheric conditions. This was particularly fortunate due to the hazy conditions during most of the experiments. A contour map of sediment, and also chlorophyll, was derived for the Chesapeake Bay plume along the southern Virginia-Carolina coastline. A sediment maximum occurs about 5 nautical miles off the Virginia Beach coast with a chlorophyll maximum slightly shoreward of this. During the James Shelf mission, a thermal anomaly (or front) was encountered about 50 miles from the coast. There was a minor variation in chlorophyll and sediment across the boundary. During the Chesapeake Bay mission, the Sun elevation increased from 50 degrees to over 70 degrees, interfering with the generation of data products
Gross efficiency and cycling performance: a review.
Efficiency, the ratio of work generated to the total metabolic energy cost, has been suggested to be a key determinant of endurance cycling performance. The purpose of this brief review is to evaluate the influence of gross efficiency on cycling power output and to consider whether or not gross efficiency can be modified. In a re-analysis of data from five separate studies, variation in gross efficiency explained ~30% of the variation in power output during cycling time-trials. Whilst other variables, notably VO2max and lactate threshold, have been shown to explain more of the variance in cycling power output, these results confirm the important influence of gross efficiency. Case study, cross-sectional, longitudinal, and intervention research designs have all been used to demonstrate that exercise training can enhance gross efficiency. Whilst improvements have been seen with a wide range of training types (endurance, strength, altitude), it would appear that high intensity training is the most potent stimulus for changes in gross efficiency. In addition to physiological adaptations, gross efficiency might also be improved through biomechanical adaptations. However, ‘intuitive’ technique and equipment adjustments may not always be effective. For example, whilst ‘pedalling in circles’ allows pedalling to become mechanically more effective, this technique does not result in short term improvements in gross efficiency
Effect of boiling point rankings and feed locations on the applicability of reactive distillation to quaternary systems
Reactive distillation (RD) offers major benefits such as costs reduction and energy saving, but the understanding and design of RD processes usually demand complex tasks that include extensive studies and rigorous simulations. To reduce this complexity and the time required, this study applies a novel mapping method to quickly provide insights into the RD applicability to reversible quaternary systems (A + B ⇌ C + D). Generic cases are used to produce applicability graphs (i.e. plots of reflux ratio vs number of theoretical stages) and multiple RD column configurations. The systems are assumed to have ideal properties and fixed key parameters (i.e. relative volatilities and chemical equilibrium constants). This study focuses on quaternary reactions considering different boiling point rankings and feed locations. Using the mapping method, quick results are achievable regarding the preliminary economic ranking of RD processes, and the optimal feed locations with reduced energy requirement (i.e. lower reflux ratio). Ultimately, this study provides a much better understanding of the effect of boiling point orders and feed locations on the RD applicability and conceptual design, being a valuable tool in early techno-economic evaluations
Gross efficiency and cycling performance: a review
Abstract Efficiency, the ratio of work generated to the total metabolic energy cost, has been suggested to be a key determinant of endurance cycling performance. The purpose of this brief review is to evaluate the influence of gross efficiency on cycling power output and to consider whether or not gross efficiency can be modified. In a re-analysis of data from five separate studies, variation in gross efficiency explained ~30% of the variation in power output during cycling time-trials. Whilst other variables, notably VO2max and lactate threshold, have been shown to explain more of the variance in cycling power output, these results confirm the important influence of gross efficiency. Case study, cross-sectional, longitudinal, and intervention research designs have all been used to demonstrate that exercise training can enhance gross efficiency. Whilst improvements have been seen with a wide range of training types (endurance, strength, altitude), it would appear that high intensity training is the most potent stimulus for changes in gross efficiency. In addition to physiological adaptations, gross efficiency might also be improved through biomechanical adaptations. However, 'intuitive' technique and equipment adjustments may not always be effective. For example, whilst 'pedalling in circles' allows pedalling to become mechanically more effective, this technique does not result in short term improvements in gross efficiency
X-ray structures of checkpoint kinase 2 in complex with inhibitors that target its gatekeeper-dependent hydrophobic pocket
AbstractThe serine/threonine checkpoint kinase 2 (Chk2) is an attractive molecular target for the development of small molecule inhibitors to treat cancer. Here, we report the rational design of Chk2 inhibitors that target the gatekeeper-dependent hydrophobic pocket located behind the adenine-binding region of the ATP-binding site. These compounds exhibit IC50 values in the low nanomolar range and are highly selective for Chk2 over Chk1. X-ray crystallography was used to determine the structures of the inhibitors in complex with the catalytic kinase domain of Chk2 to verify their modes of binding
The taxonomic status of Hypsela sessiliflora E.Wimm. (Campanulaceae)
The taxonomic status of Hypsela sessiliflora, a threatened NSW endemic, was examined using morphological and molecular data. Although the Type specimen appears to be missing and the protologue is of limited value, available evidence suggests that it is best included within a slightly broadened circumscription of the highly variable Isotoma fluviatilis subsp. fluviatilis
Comparison of aromatic hydrocarbon measurements made by PTR-MS, DOAS and GC-FID during the MCMA 2003 Field Experiment
A comparison of aromatic hydrocarbon measurements is reported for the CENICA supersite in the district of Iztapalapa during the Mexico City Metropolitan Area field experiment in April 2003 (MCMA 2003). Data from three different measurement methods were compared: a Proton Transfer Reaction Mass Spectrometer (PTR-MS), long path measurements using a UV Differential Optical Absorption Spectrometer (DOAS), and Gas Chromatography-Flame Ionization analysis (GC-FID) of canister samples. The principle focus was on the comparison between PTR-MS and DOAS data. Lab tests established that the PTR-MS and DOAS calibrations were consistent for a suite of aromatic compounds including benzene, toluene, p-xylene, ethylbenzene, 1,2,4-trimethylbenzene, phenol and styrene. The point sampling measurements by the PTR-MS and GC-FID showed good correlations (r=0.6), and were in reasonable agreement for toluene, C2-alkylbenzenes and C3-alkylbenzenes. The PTR-MS benzene data were consistently high, indicating interference from ethylbenzene fragmentation for the 145 Td drift field intensity used in the experiment. Correlations between the open-path data measured at 16-m height over a 860-m path length (retroreflector in 430 m distance), and the point measurements collected at 37-m sampling height were best for benzene (r=0.61), and reasonably good for toluene, C2-alkylbenzenes, naphthalene, styrene, cresols and phenol (r>0.5). There was good agreement between DOAS and PTR-MS measurements of benzene after correction for the PTR-MS ethylbenzene interference. Mixing ratios measured by DOAS were on average a factor of 1.7 times greater than the PTR-MS data for toluene, C2-alkylbenzenes, naphthalene and styrene. The level of agreement for the toluene data displayed a modest dependence on wind direction, establishing that spatial gradients – horizontal, vertical, or both – in toluene mixing ratios were significant, and up to a factor of 2 despite the fact that all measurements were conducted above roof level. Our analysis highlights a potential problem in defining a VOC sampling strategy that is meaningful for the comparison with photochemical transport models: meaningful measurements require a spatial fetch that is comparable to the grid cell size of models, which is typically a few 10 km2. Long-path DOAS measurements inherently average over a larger spatial scale than point measurements. The spatial representativeness can be further increased if observations are conducted outside the surface roughness sublayer, which might require measurements at altitudes as high as 10 s of metres above roof level.Alexander von Humboldt-Stiftung (Feodor Lynen fellowship)Henry & Camille Dreyfus Foundation (Postdoctral Fellowship in Environmental Chemistry
Lobelia claviflora (Campanulaceae:Lobelioideae), a new species from northern New South Wales, Australia
Lobelia claviflora Albr. & R.W.Jobson sp. nov. is described and illustrated, with notes on distribution, habitat, conservation status and features distinguishing it from closely related species of Lobelia and Isotoma
Knowledge is Power: Issues of Measuring Training and Performance in Cycling.
Mobile power meters provide a valid means of measuring cyclists’ power output in the field. These field measurements can be performed with very good accuracy and reliability making the power meter a useful tool for monitoring and evaluating training and race demands. This study examines power meter data from a Grand Tour cyclist’s training and racing and explores the inherent complications created by its stochastic nature. Simple summary methods cannot reflect a session’s variable distribution of power output or indicate its likely metabolic stress. Binning power output data, into training zones for example, provides information on the detail but not the length of efforts within a session. An alternative approach is to track changes in cyclists’ modelled training and racing performances. Both Critical Power and Record Power Profiles have been used for monitoring training-induced changes in this manner. Ultimately, new methods for quantifying the effects of training loads and modelling their implications for future performance are required. Although first proposed 40 years ago, our ability to model the effects of training on performance remain limited and merits further research
- …