20,922 research outputs found
Setting up an acupuncture knee clinic under Practice Based Commissioning
Original article can be found at: http://www.acupunctureinmedicine.org.uk/index.shtmlThis paper outlines the setting up of a new service in primary care offering acupuncture to patients with severe osteoarthritis of the knee. The high volume clinic is funded under the Practice Based Commissioning initiative and is the first of its type in the UK. It would appear to offer a model for similar services elsewhere.Peer reviewe
Seeding considerations for an LV system in a large transonic wind tunnel
When it was decided to use a laser velocimeter to measure the properties of propellers, seeding was a great concern since large particles fail to flow and small ones are too small to be seen. Many methods were tried and weeded out by using a Malvern particle sizer. The most promising ones were tested in the tunnel and the laser velocimeter (LV) measurements compared to theoretical values of veocity as the particle approached a blunt nose body along a stagnation streamline. Data obtained from the LV system were compared with the one dimensional particle lag calculation. This figure showed the theoretical velocity over the blunt nose and a velocity profile for 5 um particles. This indicated the particles were approximately 5 um. The seeding method is shown. The seed was atomized by 2 seeders run with all 12 available atomizer jets on. The atomizer seed traveled from these two seeders through four 1 inch tubes 20 feet long to the plenum chamber where this cluster of tubes injected the seed into the air stream. The tubes were located 60 feet from the model and could be moved only by shutting the tunnel down. Future seeding plans are shown
Development and utilization of a laser velocimeter system for a large transonic wind tunnel
The need for measurements of the velocity flow field about spinner propeller nacelle configurations at Mach numbers to 0.8 was met by a specially developed laser velocimeter system. This system, which uses an argon ion laser and 4 beam 2 color optics, was required to operate in the hostile environment associated with the operation of a large transonic wind tunnel. To overcome the conditions present in locating the sensitive optics in close proximity to the wind tunnel, an isolation system was developed. The system protects the velocimeter from the high vibrations, elevated temperatures, destructive acoustic pressures and low atmospheric pressures attendant with the operation of the wind tunnel. The system was utilized to map the flow field in front of, behind and in between the rotating blades of an advanced swept blade propeller model at a Mach number of 0.8. The data collected by the system will be used to correlate and verify computer analyses of propeller nacelle flow fields and propeller performance
Homological Product Codes
Quantum codes with low-weight stabilizers known as LDPC codes have been
actively studied recently due to their simple syndrome readout circuits and
potential applications in fault-tolerant quantum computing. However, all
families of quantum LDPC codes known to this date suffer from a poor distance
scaling limited by the square-root of the code length. This is in a sharp
contrast with the classical case where good families of LDPC codes are known
that combine constant encoding rate and linear distance. Here we propose the
first family of good quantum codes with low-weight stabilizers. The new codes
have a constant encoding rate, linear distance, and stabilizers acting on at
most qubits, where is the code length. For comparison, all
previously known families of good quantum codes have stabilizers of linear
weight. Our proof combines two techniques: randomized constructions of good
quantum codes and the homological product operation from algebraic topology. We
conjecture that similar methods can produce good stabilizer codes with
stabilizer weight for any . Finally, we apply the homological
product to construct new small codes with low-weight stabilizers.Comment: 49 page
Histone H1 is essential for mitotic chromosome architecture and segregation in Xenopus laevis egg extracts.
During cell division, condensation and resolution of chromosome arms and the assembly of a functional kinetochore at the centromere of each sister chromatid are essential steps for accurate segregation of the genome by the mitotic spindle, yet the contribution of individual chromatin proteins to these processes is poorly understood. We have investigated the role of embryonic linker histone H1 during mitosis in Xenopus laevis egg extracts. Immunodepletion of histone H1 caused the assembly of aberrant elongated chromosomes that extended off the metaphase plate and outside the perimeter of the spindle. Although functional kinetochores assembled, aligned, and exhibited poleward movement, long and tangled chromosome arms could not be segregated in anaphase. Histone H1 depletion did not significantly affect the recruitment of known structural or functional chromosomal components such as condensins or chromokinesins, suggesting that the loss of H1 affects chromosome architecture directly. Thus, our results indicate that linker histone H1 plays an important role in the structure and function of vertebrate chromosomes in mitosis
Measurement-Only Topological Quantum Computation
We remove the need to physically transport computational anyons around each
other from the implementation of computational gates in topological quantum
computing. By using an anyonic analog of quantum state teleportation, we show
how the braiding transformations used to generate computational gates may be
produced through a series of topological charge measurements.Comment: 5 pages, 2 figures; v2: clarifying changes made to conform to the
version published in PR
- …