    Predicting Long-Term Mortality in TAVI Patients Using Machine Learning Techniques

    Get PDF
    Background: Whereas transcatheter aortic valve implantation (TAVI) has become the gold standard for aortic valve stenosis treatment in high-risk patients, it has recently been extended to include intermediate risk patients. However, the mortality rate at 5 years is still elevated. The aim of the present study was to develop a novel machine learning (ML) approach able to identify the best predictors of 5-year mortality after TAVI among several clinical and echocardiographic variables, which may improve the long-term prognosis. Methods: We retrospectively enrolled 471 patients undergoing TAVI. More than 80 pre-TAVI variables were collected and analyzed through different feature selection processes, which allowed for the identification of several variables with the highest predictive value of mortality. Different ML models were compared. Results: Multilayer perceptron resulted in the best performance in predicting mortality at 5 years after TAVI, with an area under the curve, positive predictive value, and sensitivity of 0.79, 0.73, and 0.71, respectively. Conclusions: We presented an ML approach for the assessment of risk factors for long-term mortality after TAVI to improve clinical prognosis. Fourteen potential predictors were identified with the organic mitral regurgitation (myxomatous or calcific degeneration of the leaflets and/or annulus) which showed the highest impact on 5 years mortality

    Biolimus-A9 polymer-free coated stent in high bleeding risk patients with acute coronary syndrome: a Leaders Free ACS sub-study.

    Get PDF
    Aims: Although a true clinical challenge, high bleeding risk patients with an acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI) have never been specifically studied. Leaders Free ACS, a pre-specified Leaders Free sub-study, determined efficacy, and safety of a combination of 1-month dual anti-platelet therapy (DAPT) with implantation of either a polymer-free Biolimus-A9-coated stent (BA9-DCS) or a bare-metal stent (BMS) in these patients. Methods and results: Leaders Free included 2466 patients undergoing PCI who had at least 1 of 13 pre-defined factors for an increased bleeding risk. Of these, 659 ACS patients were included in this analysis (BA9-DCS 330, BMS 329). At 12-month follow-up, treatment with the BA9-DCS was more effective (clinically driven target-lesion revascularization 3.9 vs. 9.0%, P = 0.009) and safer (cumulative incidence of cardiac death, myocardial infarction, or definite or probable stent thrombosis 9.3 vs. 18.5%, P = 0.001), driven by significantly lower rates of cardiac mortality (3.4 vs. 6.9%, P = 0.049) and myocardial infarction (6.9 vs. 13.8%, P = 0.005). Conclusion: We believe that the results of this sub-analysis from the Leaders Free trial are likely to significantly impact clinical practice for high bleeding risk patients presenting with an ACS: the use of a BMS can, in our view, no longer be recommended, and, given the paucity of available data for second-generation DES with shortened DAPT in these patients, the BA9-DCS should currently be considered as the device with the strongest evidence to support its use for this indication

    Transcathether aortic valve implantation with the new repositionable self-expandable Evolut R versus CoreValve system: A case-matched comparison

    Get PDF
    Background: Despite promising results following transcatheter aortic valve implantation (TAVI), several relevant challenges still remain. To overcome these issues, new generation devices have been developed. The purpose of the present study was to determine whether TAVI with the new self-expanding repositionable Evolut R offers potential benefits compared to the preceding CoreValve, using propensity matching. Methods: Between June 2007 and November 2015, 2148 consecutive patients undergoing TAVI either CoreValve (n = 1846) or Evolut R (n = 302) were prospectively included in the Italian TAVI ClinicalService® project. For the purpose of our analysis 211 patients treated with the Evolut R were matched to 211 patients treated with the CoreValve. An independent core laboratory reviewed all angiographic procedural data and an independent clinical events committee adjudicated all events. Results: Patients treated with Evolut R experienced higher 1-year overall survival (log rank test p = 0.045) and a significantly lower incidence of major vascular access complications, bleeding events and acute kidney injury compared to patients treated with the CoreValve. Recapture manoeuvres to optimize valve deployment were performed 44 times, allowing a less implantation depth for the Evolut R. As a consequence, the rate of more than mild paravalvular leak and new permanent pacemaker was lower in patients receiving the Evolut R. Conclusion: In this matched comparison of high surgical risk patients undergoing TAVI, the use of Evolut R was associated with a significant survival benefit at 1. year compared with the CoreValve. This was driven by lower incidence of periprocedural complications and higher rates of correct anatomic positioning

    Relationship between coronary plaque morphology of the left anterior descending artery and 12 months clinical outcome: the CLIMA study

    Get PDF
    Abstract Aims The CLIMA study, on the relationship between coronary plaque morphology of the left anterior descending artery and twelve months clinical outcome, was designed to explore the predictive value of multiple high-risk plaque features in the same coronary lesion [minimum lumen area (MLA), fibrous cap thickness (FCT), lipid arc circumferential extension, and presence of optical coherence tomography (OCT)-defined macrophages] as detected by OCT. Composite of cardiac death and target segment myocardial infarction was the primary clinical endpoint. Methods and results From January 2013 to December 2016, 1003 patients undergoing OCT evaluation of the untreated proximal left anterior descending coronary artery in the context of clinically indicated coronary angiogram were prospectively enrolled at 11 independent centres (clinicaltrial.gov identifier NCT02883088). At 1-year, the primary clinical endpoint was observed in 37 patients (3.7%). In a total of 1776 lipid plaques, presence of MLA 180° (HR 2.4, 95% CI 1.2–4.8), and OCT-defined macrophages (HR 2.7, 95% CI 1.2–6.1) were all associated with increased risk of the primary endpoint. The pre-specified combination of plaque features (simultaneous presence of the four OCT criteria in the same plaque) was observed in 18.9% of patients experiencing the primary endpoint and was an independent predictor of events (HR 7.54, 95% CI 3.1–18.6). Conclusion The simultaneous presence of four high-risk OCT plaque features was found to be associated with a higher risk of major coronary events

    Polymer-based or polymer-free stents in patients at high bleeding risk

    Get PDF
    Background: polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited. Methods: in an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority. Results: a total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority). Conclusions: among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.)
    corecore