152 research outputs found

    Modeling and analysis of loaded multilayered magnetoelectroelastic structures composite materials: Applications

    Get PDF
    This paper presents the detailed analysis of fiber- reinforced magnetoelectroelastic composite plates. The work is divided into two major sections. The first one deals with the homogenization of the properties of each layer based on the Mori-Tanaka mean field approach where all the needed effective coefficients of each layer are determined. Then, in order to perform analysis of the considered, the Stroh formalism is used to provide solutions for multifunctional multilayered magnetoelectroelastic composites, to predict exactly the mechanical and electrical behaviors near or across the interface of material layers

    Épidémiologie des accidents domestiques graves de l’enfant admis en réanimation pédiatrique polyvalente à l’hôpital d’enfants de Rabat-Maroc

    Get PDF
    Introduction: les accidents domestiques de l'enfant représentent un vrai problème de santé publique dans les pays industrialisés. Au Maroc, lapriorité en santé publique est toujours donnée aux pathologies   infectieuses, et bien qu'elle soit très peu décrite, la pathologie accidentelle de l'enfant devient de plus en plus fréquente dans notre pays avec une mortalité importante. L'objectif est de mettre le point sur la prévalence, lagravité, les aspects étiologiques, les facteurs de risque et les circonstances de survenue de ces accidents, ainsi que les moyens de préventionactive et passive. Méthodes: enquête rétrospective descriptive sur une période de douze mois portant sur tous les enfants pris en charge pour accident domestique grave au service de réanimation pédiatrique polyvalente de l'hôpital universitaire d'enfants de Rabat. Résultats: parmi 698 admissions, 108 cas d'accidents domestiques graves ont étaient colligés (soit 15,5%), L'âge moyen des enfants était de 04ans tout accident confondu, avec un sex-ratio de 1,08 en faveur des garçons. L'évolution générale était marquée par le décès de 16 enfants (soit 14,8%) parmi 164 décès toute pathologie confondue au cours de la même période d'étude (soit 9,75% des décès) avec une durée moyenne   d'hospitalisation de 04jours. les brûlures constituaient le premier accident dans notre série par 37cas, et elles étaient la première cause de mortalité par huit cas; par ailleurs, la population la plus à risque de brûlure était les nourrissons (67,6%). L'inhalation intrabronchique d'épingle à foulard  (accident particulier dans notre contexte islamique) à été retrouvée chez six cas. Conclusion: les accidents domestiques de l'enfant constituent rarement une préoccupation de premier plan dans la population alors qu'ils sont parfois très graves et source d'une mortalité importante. Le meilleur  traitement reste la prévention active et passive

    Modeling and analysis of loaded multilayered magnetoelectroelastic structures composite materials: Applications

    Get PDF
    This paper presents the detailed analysis of fiber- reinforced magnetoelectroelastic composite plates. The work is divided into two major sections. The first one deals with the homogenization of the properties of each layer based on the Mori-Tanaka mean field approach where all the needed effective coefficients of each layer are determined. Then, in order to perform analysis of the considered, the Stroh formalism is used to provide solutions for multifunctional multilayered magnetoelectroelastic composites, to predict exactly the mechanical and electrical behaviors near or across the interface of material layers

    Corrosion Inhibition Influence of the Synthetized Chromen-6-One Derivatives on Mild Steel in 1.0 M HCl Electrolyte: Electrochemical, Spectroscopic and Theoretical Investigations

    Get PDF
    In this work, two new chromen-6-one derivatives (BCC), namely 7-phenyl-6H,7H-benzo[f]chromeno[4,3-b] chromen-6-one (BCC-Ph) and 7-(furan-2-yl)-6H, 7H-benzo[f] chromeno [4,3-b] chromen-6-one (BCC-Fur), were prepared and identified by spectroscopic technique (NMR). Their performances inhibitions were assessed by electrochemical measurements, and they confirmed and explained using scanning electron microscope combined with energy dispersive X-ray spectroscopy (SEM/EDX) and theoretical studies (DFT calculation and MD simulation). Both electrochemical techniques revealed that the obtained performance value rises with the content of inhibitors to reach 94.94% and 83.57% at 10-3 M BCC-Ph and BCC-Fur, correspondingly. Moreover, according to the PDP method, these compounds behave as mixed-type inhibitors in 1.0 M HCl medium. In addition, the influence of temperature indicated that the performance of the chromen-6-one derivatives slightly decreases with the temperature, and they are characterized by the physico-chemical adsorptions process with chemical dominance, and they act according to the Langmuir approach. The SEM/EDX analysis revealed a significant reduction of the heterogeneity of the metal surface by the establishment of anti-corrosive layer. Finally, the DFT calculations and MD simulation explain the mode of the chromen-6-one derivatives molecules adsorption, and confirm the obtained experimental results

    Anaerobic co-digestion of pear residues and sewage sludge using a CSTR digester. Influence of the feed procedure

    Get PDF
    Anaerobic co-digestion of pear residues with sewage sludge is feasible. Important differences are obtained from the two feed regimes tested, with better results for the so-called continuous feed. The organic loading rate (OLR) is the important parameter for the methane productionUniversidad de Málaga. Campus de Excelencia Internacional Andalucía Tech

    Green approach to corrosion inhibition of mild steel in 1 M HCl solutions by Monosaccharides derivatives

    Get PDF
    Effect of new synthesized monosaccharide derivatives, namely: D-mannose (M1), D-gluconic acid-γ-lactone (M2), D-galactono-γ-lactone (M3), monoacetoneglucose (M4), diacetoneglucose (M5), on mild steel corrosion inhibition in an aerated acidic solution of 1 M HCl was investigated using weight loss, potentiodynamic polarization curves, and electrochemical impedance spectroscopy measurements. The results indicate that the type of inhibition depends on the type of compounds. Impedance measurements showed that the charge transfer resistance increased and double layer capacitance values decreased with inhibitor’s concentration. It is seen that the M2 performed excellently as a corrosion inhibitor which its efficiency reaches 91 % at 10-3 M. Adsorption of M2 molecules on mild steel surface was also studied to examine basic information on the interaction between the inhibitors and the metal surface. It is found that the inhibitor adsorb on the metal surface following the Langmuir isotherm model. The temperature effect on the performance of mild steel in 1 M HCl in the absence and presence of the best compound was studied in the temperature range from 293 to 323 K. Also, some thermodynamic data for the adsorption and dissolution processes are calculated and discussed

    Effect of NaHCO3 addition on the anaerobic co-digestion of fruit and vegetable waste and sewage sludge performance

    Get PDF
    Digestion of FVW residues with sewage sludge is feasible as long as the FVW to sludge ratio fed to the batch digester is not too large. The pH is the main variable determining the reactor performance and can be controlled by NaHCO3 addition.Universidad de Málaga. Campus de Excelencia Internacional Andalucía Tech

    Etude épidémiologique de la rhinopneumonie chez les équidés au Maroc

    Get PDF
    Lors d'une enquête sérologique sur la rhinopneumonie équine au Maroc, 4 775 prélèvements (59,6 % de chevaux, 18 % de mulets et 22,4 % d'ânes) ont été réalisés durant cinq ans (de 1990 à 1994) dans les différentes régions du pays. La séroprévalence globale de l'infection était de 39 %. Les ânes (46 %) étaient plus affectés que les mulets (42 %) et les chevaux (35 %). En outre, chez les trois espèces, la séroprévalence a augmenté avec l'âge jusqu'à trois ans pour atteindre la valeur de 42 % et elle s'est stabilisée pour les animaux plus âgés. Il n'est pas certain que le sexe et la région géographique où vivaient les animaux les prédisposaient à la maladie. Par contre, leurs conditions d'entretien ont constitué un facteur prédisposant à l'infection. Après une stabilisation pendant les quatre premières années, l'incidence de l'infection s'est subitement accrue en 1994 à cause de la sécheresse qui a sévi cette année-là

    Effect of the feed procedure on production of biogas from anaerobic digestion of pear residues using a CSTR Digester

    Get PDF
    The anaerobic digestion for the production of biogas is one of the best alternative management procedures of the fruits and vegetables wastes (FWV) since it simultaneously allows energy recovery and material recycling if the digestate can be used for soil amendment. Nevertheless, the generation of this kind of residues is frequently concentrated in only few weeks per year, imposing a serious economic limitation. Thus, introduction of the FVW into the anaerobic digester of the municipal wastewaster treatment plant (MWTP) is a very interesting approach. The aim of this work was to investigate the digestion of pear residues using the anaerobic sludge obtained from a MWTP digester under mesophilic conditions and to explore the influence of the feed operating conditions using a continuously stirred tank reactor (CSTR) digester. The results indicate that the continuous feed allows the treatment of almost twice as much residue (10.5 vs 6.0 g L–1 d-1). System instabilities are observed at larger OLRs.Universidad de Málaga. Campus de Excelencia Internacional Andalucía Tech
    • …
    corecore