19 research outputs found
Doble role of bathocuproine disulfonic acid as multi-walled carbon nanotubes dispersing agent and copper preconcentration ligand: Analytical applications for the development of hydrogen peroxide and glucose electrochemical sensors
We are reporting a new strategy for preparing carbon nanotubes (CNTs)-based hydrogen peroxide and glucose amperometric sensors by taking advantage of the dual role of bathocuproine disulfonic acid (BCS) as dispersing agent of multi-walled carbon nanotubes (MWCNTs) and as ligand for the preconcentration of Cu(II). The platform was obtained by casting glassy carbon electrodes (GCE) with the dispersion of MWCNTs in BCS (MWCNTs-BCS) followed by the preconcentration of Cu(II) by surface complex formation at open circuit potential (GCE/MWCNTs-BCS/Cu). The resulting electrode was used for the sensitive amperometric quantification of hydrogen peroxide at 0.400 V catalyzed by the preconcentrated copper, with a linear range between 5.0 × 10−7 and 7.4 × 10-6 M, a sensitivity of 24.3 mA.M-1, and a detection limit of 0.2 μM. The adsorption of GOx at GCE/MWCNTs-BCS/Cu followed by the immobilization of Nafion (Naf), allowed the construction of a sensitive and selective amperometric glucose biosensor with a linear range between 5.0 × 10-6 M and 4.9 × 10-4 M, a sensitivity of (477 ± 3) μA.M-1 and a detection limit of 2 μM. The proposed (bio)sensors were successfully used for the quantification of hydrogen peroxide in enriched milk samples and glucose in milk and commercial beverages without any pretreatment.Fil: Gallay, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Rodriguez, Marcela Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Eguílaz Rubio, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentin
Nanoarchitectures based on multi-walled carbon nanotubes non-covalently functionalized with Concanavalin A: A new building-block with supramolecular recognition properties for the development of electrochemical biosensors
We propose an innovative nanoarchitecture for the development of electrochemical biosensors based on the non-covalent functionalization of multi-walled carbon nanotubes (MWCNTs) with the lectin Concanavalin A (ConA) and the site-specific supramolecular binding of glycobiomolecules. As proof-of-concept, we propose the use of two glycoenzymes, glucose oxidase (GOx) and horseradish peroxidase (HRP), for building mono and bienzymatic glucose biosensors. The selected conditions for the preparation of the dispersion were 1.5 mg MWCNTs in 1.0 mL of 2.0 mg mL −1 ConA sonicated for 5.0 min with sonicator probe. The monoenzymatic glucose biosensor was prepared by casting GCE with the MWCNTs-ConA dispersion (GCE/MWCNTs-ConA) followed by the interaction with GOx (GCE/MWCNTs-ConA/GOx), while the bienzymatic one was obtained by interaction of GCE/MWCNTs-ConA with GOx + HRP (GCE/MWCNTs-ConA/GOx-HRP). The best analytical performance was obtained with the bienzymatic biosensor from the amperometric response at -0.050 V in the presence of 1.0 × 10 -4 M hydroquinone. The sensitivity was (2.22 ± 0.03) μA mM −1 (which was 5.2 times higher than the one obtained with the monoenzymatic biosensor) and a detection limit of 0.31 μM. The reproducibility was 5.4% and the biosensor was challenged with human blood serum showing an excellent correlation with the values reported by the laboratory.Fil: Ortiz, Elvis. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina. Universidad Autónoma Metropolitana Iztapalapa; MéxicoFil: Gallay, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Galicia, Laura. Universidad Autónoma Metropolitana Iztapalapa; MéxicoFil: Eguílaz Rubio, Marcos. Universidad Autónoma Metropolitana Iztapalapa; MéxicoFil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentin
Co2TiO4/reduced graphene oxide nanohybrids for electrochemical sensing applications
For the first time, the synthesis, characterization, and analytical application for hydrogen peroxide quantification of the hybrid materials of Co2TiO4 (CTO) and reduced graphene oxide (RGO) is reported, using in situ (CTO/RGO) and ex situ (CTO+RGO) preparations. This synthesis for obtaining nanostructured CTO is based on a one-step hydrothermal synthesis, with new precursors and low temperatures. The morphology, structure, and composition of the synthesized materials were examined using scanning electron microscopy, X-ray diffraction (XRD), neutron powder diffraction (NPD), and X-ray photoelectron spectroscopy (XPS). Rietveld refinements using neutron diffraction data were conducted to determine the cation distributions in CTO. Hybrid materials were also characterized by Brunauer-Emmett-Teller adsorption isotherms, Scanning Electron microscopy, and scanning electrochemical microscopy. From an analytical point of view, we evaluated the electrochemical reduction of hydrogen peroxide on glassy carbon electrodes modified with hybrid materials. The analytical detection of hydrogen peroxide using CTO/RGO showed 11 and 5 times greater sensitivity in the detection of hydrogen peroxide compared with that of pristine CTO and RGO, respectively, and a two-fold increase compared with that of the RGO+CTO modified electrode. These results demonstrate that there is a synergistic effect between CTO and RGO that is more significant when the hybrid is synthetized through in situ methodology.Fil: Venegas, Constanza J.. Universidad de Chile; Chile. Universidad de Santiago de Chile; ChileFil: Gutierrez, Fabiana Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Eguílaz Rubio, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Marco, José F.. Consejo Superior de Investigaciones Científicas; EspañaFil: Reeves-McLaren, Nik. University Of Sheffield; Reino UnidoFil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Ruiz-León, Domingo. Universidad de Santiago de Chile; ChileFil: Bollo, Soledad. Universidad de Chile; Chil
Recent advances in the development of electrochemical hydrogen peroxide carbon nanotube–based (bio)sensors
The relevance of H2O2 as biomarker for different neurodegenerative diseases and cancer has been one of the most significant incentives for the development of new (bio)sensors that allow a more sensitive, selective, fast, and stable quantification of H2O2. In this regard, the association of carbon nanotubes with hemoproteins, nanoparticles, and other nanostructures and different electrochemical transducers has offered new avenues for the construction of innovative H2O2 bioanalytical platforms. This short review highlights the most relevant contributions in the field of electrochemical (bio)sensors for H2O2 based on carbon nanotubes published in the period 2016–2018.Fil: Eguílaz Rubio, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Dalmasso, Pablo Roberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Rubianes, María Dolores. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Gutierrez, Fabiana Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Rodriguez, Marcela Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Gallay, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: López Mujica, Michael Earvin. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Ramírez, María Laura. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Tettamanti, Cecilia Soledad. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Montemerlo, Antonella Evelin. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentin
Estrategias de modificación de electrodos para la preparación de superficies biosensoras
Tesis inédita de la Universidad Complutense de Madrid, Facultad de Ciencias Químicas, Departamento de Química Analítica, leída el 23/02/2012Depto. de Química AnalíticaFac. de Ciencias QuímicasTRUEunpu
Designing electrochemical interfaces based on nanohybrids of avidin functionalized-carbon nanotubes and ruthenium nanoparticles as peroxidase-like nanozyme with supramolecular recognition properties for site-specific anchoring of biotinylated residues
We are reporting an original supramolecular architecture based on a rationally designed new nanohybrid with enhanced peroxidase-like activity and site-specific biorecognition properties using avidin-functionalized multi-walled carbon nanotubes (MWCNTs-Av) and Ru nanoparticles (RuNPs). The nanohybrid-electrochemical interface was obtained by drop-coating of MWCNTs-Av dispersion at glassy carbon electrodes (GCE) followed by solvent evaporation and further electrodeposition of RuNPs (50 ppm RuCl2 for 15 s at -0.600 V). The simultaneous presence of MWCNTs and RuNPs produces a synergic effect on the non-enzymatic catatalytic reduction of H2O2 and allows the quantification of H2O2 in a wide linear range (from 5.0 × 10−7 M to 1.75 × 10−3 M) with a low limit of detection (65 nM). The avidin residues present in MWCNTs-Av/RuNPs hybrid nanomaterial allowed the anchoring by bioaffinity of biotinylated glucose oxidase (biot-GOx) as proof-of-concept of the analytical application of MWCNTs-Av platform for biosensors development. The resulting nanoarchitecture behaves as a bienzymatic-like glucose biosensor with a competitive analytical performance: linear range between 2.0 × 10−5 M and 1.23 × 10−3 M, sensitivity of (0.343 ± 0.002) μA mM−1 or (2.60 ± 0.02) μA mM−1 cm−2, detection limit of 3.3 μM, and reproducibility of 5.2% obtained with five different GCE/MWCNTs-Av/RuNPs/biot-GOx bioplatforms prepared the same day using the same MWCNTs-Av dispersion, and 9.1% obtained with nine biosensors prepared in different days with nine different MWCNTs-Av dispersions. The average concentrations of glucose in Gatorade®, Red bull® and Pepsi® with the biosensor demonstrated excellent agreement with those reported in the commercial beverages.Fil: Gallay, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Eguílaz Rubio, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentin
Electrochemical biointerfaces based on carbon nanotubes-mesoporous silica hybrid material: Bioelectrocatalysis of hemoglobin and biosensing applications
We are reporting a novel biosensing platform based on a hybrid nanomaterial that combines the advantages of Nafion-coated multiwalled carbon nanotubes (MWCNTs) and mesoporous silica MCM41 nanoparticles functionalized with hemoglobin (Hb). MWCNTs-MCM41-Hb hybrid bioconjugate was characterized by scanning electron microscopy (SEM), UV–vis spectroscopy and electrochemical techniques after deposition at glassy carbon electrodes (GCE). The combination of the high surface area, biocompatibility and protein loading capacity of MCM41 nanoparticles and the high surface area and catalytic properties of MWCNTs allowed the direct electron transfer (DET) between Hb and the electrode surface. The electron transfer rate constant (k) and the surface coverage of electroactive Hb (ΓHb) were 5.2 s−1 and 4.7 × 10−10 mol cm−2, respectively. The GCE modified with the nanostructured architecture (GCE/MWCNTs-MCM41-Hb) was successfully used as a third-generation biosensor for the highly sensitive and selective quantification of nitrite (NO2 -) and trichloroacetic acid (TCA) by taking advantage of the excellent biocatalytic activity of Hb and the efficient direct charge transfer of the heme group.Fil: Eguílaz Rubio, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Villalonga, Reynaldo. Universidad Complutense de Madrid; EspañaFil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentin
Multi-walled carbon nanotubes non-covalently functionalized with Polyarginine: A new alternative for the construction of Reagentless NAD + /Dehydrogenase-based Ethanol Biosensor
This work reports for the first time the development of a reagentless enzymatic amperometric biosensor for ethanol based on the use of a glassy carbon electrode (GCE) modified with multi-walled carbon nanotubes (MWCNTs) non-covalently functionalized with polyarginine (Polyarg) as platform for the robust immobilization of alcohol dehydrogenase (ADH) and NAD + . The new strategy allows to obtain an integrated GCE/MWCNTs-Polyarg/NAD + -ADH ethanol biosensor with important advantages compared to the existing ethanol biosensors: avoids the external addition of the cofactor for each measurement, ensures a fast and sensitive quantification of ethanol due to the intimate interaction of the components, and allows the detection at considerably lower potentials due to the catalytic activity of the carbon nanostructures. These unique properties have made possible a very efficient ethanol quantification with a sensitivity of (1487±6) μA M −1 , detection limit of 0.65 μM, response time of 8 s, and reproducibility of 5.5 % with a very successful application for the quantification of ethanol in different commercial beverages.Fil: Gallay, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Eguílaz Rubio, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentin
Non-covalent functionalization of multi-wall carbon nanotubes with polyarginine: Characterization and analytical applications for uric acid quantification
We report for the first time the non-covalent functionalization of multiwall carbon nanotubes (MWCNTs) with polyarginine (Polyarg), the modification of glassy carbon electrodes (GCE) with the resulting Polyarg-MWCNTs dispersion and the analytical application of Polyarg-MWCNTs-modified GCE for the quantification of uric acid. The optimum MWCNT-Polyarg dispersion was obtained by sonicating for 5.0 min the mixture of 0.75 mg mL−1 MWCNTs and 0.50 mg mL−1 Polyarg. The dispersion was characterized by scanning electron microscopy, electrophoretic mobility, electrochemical impedance spectroscopy, cyclic voltammetry and amperometry. The presence of MWCNT-Polyarg at GCE surface produced a drastic decrease in the overvoltages for the oxidation of hydrogen peroxide (300 mV) ascorbic acid (281 mV) and uric acid (70 mV) and for the reduction of hydrogen peroxide (200 mV), as well as an important decrease in the charge transfer resistances for hydrogen peroxide, hydroquinone/quinone and ferricyanide/ferrocyanide markers. The strong adsorption of uric acid at GCE/MWCNT-Polyarg made possible the highly sensitive detection of this biomarker at nanomolar levels even in the presence of 1.0×10−4 M ascorbic acid by Adsorptive Stripping with medium exchange and linear scan voltammetry transduction. The quantification of uric acid in untreated human urine was very successful, demonstrating an excellent correlation (98 %) with the reference method used in clinical laboratories (Uricostat, Wiener Lab).Fil: Gutierrez, Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Gutierrez, Fabiana Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Eguílaz Rubio, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Parrado, Concepción. Universidad Complutense de Madrid; EspañaFil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentin
Multi-walled carbon nanotubes functionalized with bathocuproinedisulfonic acid: Analytical applications for the quantification of Cu(II)
This work reports the successful non-covalent functionalization of multi-walled carbon nanotubes (MWCNTs) with bathocuproinedisulfonic acid (BCS) and the analytical application of the resulting dispersion (MWCNTs-BCS) to develop an electrochemical sensor for Cu(II) quantification. The sensor was obtained by casting glassy carbon electrodes (GCEs) with MWCNTs-BCS. The sensing mechanism was based on the open circuit preconcentration of Cu(II) at the electrode surface by complexation of Cu(II) through the phenanthroline ring nitrogen of the BCS that supports the MWCNTs, the reduction of the preconcentrated Cu(II), and final differential pulse voltammetry-anodic stripping in 0.020 M acetate buffer, pH 5.00. The sensitivity of the sensor was (2.73 ± 0.08) μA μM−1, with a linear range between 5.0 × 10−7 M and 6.0 × 10−6 M, a detection limit of 0.15 μM (9.5 μg L−1), and reproducibility of 6.2% using the same dispersion and 7.1% using three different MWCNTs-BCS dispersions. The quantification of Cu(II) was highly selective even in the presence of As3+, Cr3+, Cd2+, Ni2+, Pb2+, Co2+, Zn2+, Fe2+, Hg2+, Rh, Ir, and Ru. The proposed sensor was successfully used for quantifying Cu(II) in tap water.Fil: Saldaña, Jorge Ramiro Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Gallay, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Gutierrez, Silvia. Universidad de Guanajuato; MéxicoFil: Eguílaz Rubio, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentin