130 research outputs found

    Brachial Approach As an Alternative Technique of Fibrin Sheath Removal for Implanted Venous Access Devices.

    Get PDF
    Implanted venous access device (IVAD) late dysfunction is commonly caused by fibrin sheath formation. The standard method of endovascular fibrin sheath removal is performed via the femoral vein. However, it is not always technically feasible and sometimes contraindicated. Moreover, approximately 4-6 h of bed rest is necessary after the procedure. In this article, we describe an alternative method of fibrin sheath removal using the brachial vein approach in a young woman receiving chemotherapy for breast cancer. The right basilic vein was punctured, and a long 6°F introducer sheath was advanced into the right subclavian vein. Endovascular maneuvers consisted on advancing Atrieve™ Vascular Snare 15-9 mm after catheter insertion in the superior vena cava through a 5.2°F Judkins left catheter. IVAD patency was restored without any complication, and the patient was discharged immediately after the procedure. In conclusion, fibrin sheath removal from an obstructed IVAD could be performed via the right brachial vein. Further research is necessary in order to prove efficacy of this technique

    Pathomorphological and CT-angiographical characteristics of coronary atherosclerotic plaques in cases of sudden cardiac death.

    Get PDF
    The goal of this study was to assess the localization and types of thrombosed plaques in cases of sudden cardiac death attributed to coronary artery disease and to evaluate possible correlations with body mass index (BMI) and increased heart weight. This retrospective study was performed on forensic cases for which the cause of death was attributed to coronary artery disease. A complete autopsy and a multi-phase postmortem computed tomography (CT) angiography (MPMCTA) were performed in all cases. Eighty-five cases were selected (mean age, 55.18 ± 11.04 years; 72 men and 13 women). MPMCTA performed prior to autopsy enabled an evaluation of coronary artery perfusion before dissection of the body and helped therefore to guide sampling for histology. An acute coronary thrombosis was found in 57 cases, which included plaque erosion in 26 cases (mean age, 46.73 ± 8.33 years) and rupture or intra-plaque hemorrhage in 31 cases (mean age, 58.23 ± 10.62 years). Erosions were most frequently found in the left anterior descending artery (61.5%), while only 35.48% of ruptures were observed in this artery. Chronic coronary pathology was considered as the main cause of death in 28 cases (mean age, 59.64 ± 9.47 years). Sixty-two of the cases (72.94%) had a BMI in the overweight category (BMI ≥25), with the highest mean BMI in patients with chronic coronary pathology without acute thrombosis found at autopsy. The heart weight was above the predicted reference values in 52 cases (61.18%). Our results are in accordance with previously published studies on the spatial distribution of vulnerable plaques. We observed a higher percentage of eroded plaques than previously reported. Patients with coronary erosions were significantly younger than those with plaque rupture or those without an acute coronary thrombosis (p values <0.0001). BMI and heart weight were significantly higher for cases without thrombosis in comparison with those with plaque rupture (p values 0.028 and 0.003, respectively). Our results indicating that increased BMI and overweight hearts are associated with chronic ischemic heart disease are compatible with clinical studies. Performing more postmortem studies on forensic autopsies, including modern radiological examinations with MPMCTA, can enhance the detection of vulnerable plaques in living patients and prevent sudden cardiac death

    Development and validation of a postmortem radiological alteration index: the RA-Index

    Get PDF
    This study aimed to derive an index quantifying the state of alteration of cadavers by quantifying the presence of gas in the body using postmortem multidetector computed tomography (MDCT) imaging, and to validate the index by defining its sensitivity and specificity. The RA (radiological alteration)-index was derived from postmortem MDCT data from 118 nontraumatically deceased people. To validate the index, 100 additional scanned bodies (50 % traumatically deceased) were retrospectively examined by two independent observers. Presence of gas at 82 sites was assessed by a radiologist, whereas a forensic pathologist only investigated the seven sites used for the RA-index. The RA-index was highly correlated to the overall presence of gas in all 82 sites (R2 = 0.98 in the derivation set and 0.85 in the validation set). Semiquantitative evaluation of gas presence in each site showed moderate reliability (Cohen's kappa range, 0.41-0.78); nevertheless, the overall RA-index was very reliable (ICC2,1 = 0.95; 95 % CI 0.92-0.96). Examiner using the RA-index detected heart cavities full of gas with a sensitivity of 100 % (95 % CI 51.7-100) and a specificity of 98.8 % (92.6-99.9). We conclude that determining the presence of gas at seven sites is a valid means to measure the distribution of gas due to cadaveric alteration in the entire body. The RA-index is rapid, easy-to-use, and reliable for nonexperienced users, and it is a valid method to suspect the normal presence of gas from cadaveric alteration. MDCT can be used to screen for gas embolism and to give indications for gas composition analysis (gas chromatography

    Superior Vena Cava (SVC) Endovascular Reconstruction with Implanted Central Venous Catheter Repositioning for Treatment of Malignant SVC Obstruction.

    Get PDF
    Superior vena cava (SVC) syndrome is a group of clinical signs caused by the obstruction or compression of SVC and characterized by edema of the head, neck, and upper extremities, shortness of breath, and headaches. The syndrome may be caused by benign causes but most of the cases are caused by lung or mediastinal malignant tumors. Stenting of SVC has become widely accepted as the palliative treatment for this condition in malignant diseases, as it offers rapid relief of symptoms and improves the quality of life. Preserving previously placed central venous catheters (CVCs) is a major issue in this population. We report the case of a patient with SVC syndrome caused by tumoral obstruction due to central small-cell lung cancer who had right subclavian implanted CVC and a preferential head and neck venous drainage through the left internal jugular and brachiocephalic vein (BCV). We describe a complex procedure of SVC reconstruction with two different objectives: left recanalization and stent placement to ensure head and neck venous drainage and right BCV stenting for CVC repositioning and subsequent replacement. We also review published cases of SVC obstructions stenting with catheter repositioning. The patient experienced quick relief of symptoms after treatment. Chemotherapy was rapidly delivered through the preserved implanted CVC access. A 3-month follow-up computed tomography showed stents patency

    Application of multi-phase postmortem CT-angiography in the investigation of vascular pathology and modified vascular anatomy: a special case of "vascular patchwork".

    Get PDF
    Multi-phase postmortem CT-angiography (MPMCTA) is used routinely for investigating cases of traumatic and natural death at the University Centre of Legal Medicine, Lausanne-Geneva. Here, we report the case of a patient affected by Leriche syndrome, with a history of numerous cardiovascular interventions, including an axillobifemoral bypass. The multiple cardiovascular changes presented by the patient were visualised by this relatively new technique and they were shown not to be related to the cause of death. This case demonstrated the utility of MPMCTA for investigating bodies with suspected vascular pathologies. Moreover, it revealed the advantages of MPMCTA over conventional autopsy to investigate a modified vascular anatomy. This was the first case in which MPMCTA was performed by injecting a contrast-agent mixture into a vascular prosthesis

    Structured team-oriented program to follow patients after vena cava filter placement: a step forward in improving quality for filter retrieval.

    Get PDF
    To reduce inferior vena cava filter (IVCF) related complications, retrieval is recommended whenever possible. Nevertheless, IVCF retrieval rates remain lower than expected, likely due to insufficient follow-up after placement. We evaluated the value of a structured program designed to follow patients by the interventional radiology team up to 5 months after IVCF placement. We prospectively enrolled 366 consecutive patients (mean age 64 ± 17 years; 201 men and 165 women) who benefited from IVCF between March 2015 and February 2020. The program consisted of advising the patient and clinicians to consider IVCF retrieval as soon as possible (standard workflow) and systematically planning an additional follow-up visit at 5-month. Clinical and technical eligibility, as well as technical success for retrieval (TSR) were evaluated. At 5-months, 38 (10.4%) patients were lost to follow-up, and 47 (12.8%) had died. Among survivors, the overall retrieval rate was 58%. The retrieval rates were 83% and 97% for the clinically eligible and technically eligible patients for retrieval, respectively. The 5-month visit enabled 89 additional retrievals (47.8%) compared to the standard workflow. No significant difference was seen in TSR before and after 5 months (p = 0.95). Improved patient tracking with a dedicated IVCF program results in an effective process to identify suitable patients for retrieval and drastically improves retrieval rates in eligible patients. Involving interventionalists in the process improved IVCF patient management

    Assessment of occlusive arterial disease of abdominal aorta and lower extremities arteries: value of multidetector CT angiography using an adaptive acquisition method

    Get PDF
    We evaluated 16-detector-row CT in the assessment of occlusive peripheral arterial disease (PAD) of the abdominal aorta and lower extremities using an adaptive method of acquisition to optimise arterial enhancement especially for the distal foot arteries. Thirty-four patients underwent transcatheter angiography (TCA) and CT angiography within 15days. For each patient, table speed and rotation were selected according to the calculated optimal transit time of contrast material obtained after a single bolus test and two dynamic acquisitions at aorta and popliteal arteries. Analysis included image quality and detection of stenosis equal or greater than 50% on a patient basis and on an arterial segment basis. Sensitivity and specificity of CT were calculated with the TCA considered as the standard of reference. CT was conclusive in all segments with no technical failures even in difficult cases with occluded bypasses and aneurysms. On patient-basis analysis, the overall sensitivity and specificity to detect significant stenosis greater than 50% were both 100%. Segmental analysis shows high values of sensitivity and specificity ranging from 91 to 100% and from 81 to 100%, respectively, including distal pedal arteries. Sixteen-detector-row CT angiography using an adaptive acquisition improves the image quality and provides a reliable non-invasive technique to assess occlusive peripheral arterial disease, including distal foot arterie

    Multi-phase postmortem CT angiography: recognizing technique-related artefacts and pitfalls

    Get PDF
    Background and purpose: Multi-phase postmortem CT angiography (MPMCTA) is increasingly being recognized as a valuable adjunct medicolegal tool to explore the vascular system. Adequate interpretation, however, requires knowledge about the most common technique-related artefacts. The purpose of this study was to identify and index the possible artefacts related to MPMCTA. Material and methods: An experienced radiologist blinded to all clinical and forensic data retrospectively reviewed 49 MPMCTAs. Each angiographic phase, i.e. arterial, venous and dynamic, was analysed separately to identify phase-specific artefacts based on location and aspect. Results: Incomplete contrast filling of the cerebral venous system was the most commonly encountered artefact, followed by contrast agent layering in the lumen of the thoracic aorta. Enhancement or so-called oedematization of the digestive system mucosa was also frequently observed. Conclusion: All MPMCTA artefacts observed and described here are reproducible and easily identifiable. Knowledge about these artefacts is important to avoid misinterpreting them as pathological finding

    Development and validation of a postmortem radiological alteration index: the RA-Index.

    Get PDF
    This study aimed to derive an index quantifying the state of alteration of cadavers by quantifying the presence of gas in the body using postmortem multidetector computed tomography (MDCT) imaging, and to validate the index by defining its sensitivity and specificity. The RA (radiological alteration)-index was derived from postmortem MDCT data from 118 nontraumatically deceased people. To validate the index, 100 additional scanned bodies (50 % traumatically deceased) were retrospectively examined by two independent observers. Presence of gas at 82 sites was assessed by a radiologist, whereas a forensic pathologist only investigated the seven sites used for the RA-index. The RA-index was highly correlated to the overall presence of gas in all 82 sites (R(2) = 0.98 in the derivation set and 0.85 in the validation set). Semiquantitative evaluation of gas presence in each site showed moderate reliability (Cohen's kappa range, 0.41-0.78); nevertheless, the overall RA-index was very reliable (ICC(2,1) = 0.95; 95 % CI 0.92-0.96). Examiner using the RA-index detected heart cavities full of gas with a sensitivity of 100 % (95 % CI 51.7-100) and a specificity of 98.8 % (92.6-99.9). We conclude that determining the presence of gas at seven sites is a valid means to measure the distribution of gas due to cadaveric alteration in the entire body. The RA-index is rapid, easy-to-use, and reliable for nonexperienced users, and it is a valid method to suspect the normal presence of gas from cadaveric alteration. MDCT can be used to screen for gas embolism and to give indications for gas composition analysis (gas chromatography)
    corecore