95 research outputs found
Paper-based devices as new smart analytical tools for sustainable detection of environmental pollutants
The use of paper as a multifunctional material in electrochemical sensing has been intensively explored over the
last decade. The combination among different kinds of paper as well as their coupling with different electro chemical cell configurations have been demonstrated, disclosing innovative sensing performances and features
that are still to be fully investigated. This ongoing research has found applications in a variety of fields, including
the biomedical, agri-food, security, and environmental ones, thanks to the high versatility and adaptability of the
paper material. In this review, we report a critical and comparative analysis of electrochemical devices based on
paper published within 2010–2021 and applied for the detection of pollutants of environmental interest in fresh
water, seawater, and other real environmental matrices. Several paper types, from common office paper to
Whatman filter paper with different filtering grades, were proved to be useful in this field. In detail, the
multifarious roles played by the paper are discussed, highlighting how the paper can be a suitable material for
electrochemical sensing while being capable of simplifying the measurement of complex real matrices or real izing programmable origami-like structures. Among the most important pollutants, a special focus is dedicated to
the emerging pollutants. Furthermore, the unique advantages achieved by the paper have been analyzed and
highlighted, reporting the future perspectives regarding the use of this surprising material
Fast, sensitive and cost-effective detection of nerve agents in the gas phase using a portable instrument and an electrochemical biosensor
Abstract The nerve agents are chemical warfare agents known to be used during terrorist attacks. An inexpensive and portable system to be used by first responders and military personnel is of interest owing to the continuing threat of possible terrorist attacks. Amperometric biosensors based on cholinesterase inhibition show such potentialities. In this work butyrylcholinesterase was immobilized onto screen-printed electrodes modified with Prussian blue and the nerve agent detection was performed by measuring the residual activity of enzyme. The optimized biosensor was tested with sarin and VX standard solutions, showing detection limits of 12 and 14 ppb (10% of inhibition), respectively. The enzymatic inhibition was also obtained by exposing the biosensors to sarin in gas phase. Two different concentrations of sarin gas (0.1 and 0.5 mg m −3 ) at different incubation times (from 30 s up to 10 min) were tested. It is possible to detect sarin at a concentration of 0.1 mg m −3 with 30-s incubation time, with a degree of inhibition of 34%, which match the legal limits (immediate danger to life and health)
Experimental comparison in sensing breast cancer mutations by signal on and signal off paper-based electroanalytical strips
Altres ajuts: the ICN2 is funded by the CERCA Programme/Generalitat de Catalunya.The development of paper-based electroanalytical strips as powerful diagnostic tools has gained a lot of attention within the sensor community. In particular, the detection of nucleic acids in complex matrices represents a trending topic, especially when focused toward the development of emerging technologies, such as liquid biopsy. DNA-based biosensors have been largely applied in this direction, and currently, there are two main approaches based on target/probe hybridization reported in the literature, namely Signal ON and Signal OFF. In this technical note, the two approaches are evaluated in combination with paper-based electrodes, using a single strand DNA relative to H1047R (A3140G) missense mutation in exon 20 in breast cancer as the model target. A detailed comparison among the analytical performances, detection protocol, and cost associated with the two systems is provided, highlighting the advantages and drawbacks depending on the application. The present work is aimed to a wide audience, particularly for those in the field of point-of-care, and it is intended to provide the know-how to manage with the design and development stages, and to optimize the platform for the sensing of nucleic acids using a paper-based detection method
Amperometric separation-free immunosensor for real-time environmental monitoring
Immunoanalytical techniques have found widespread use due to the characteristics of specificity and wide applicability for many analytes, from large polymer antigens, to simple haptens, and even single atoms. Electrochemical sensors offer benefits of technical simplicity, speed and convenience via direct transduction to electronic equipment. Together, these two systems
offer the possibility of a convenient, ubiquitous assay technique with high selectivity. However, they are still not widely used, mainly due to the complexity of the associated immunoassay methodologies. A separation-free immunoanalytical technique is described here, which has allowed for the analysis of atrazine in real time and in both quasi-equilibrium and stirred batch configurations. It illustrated that determinations as low as 0.13mM (28 ppb) could be made using equilibrium incubation with an analytical range of 0.1–10mM. Measurements could be made between 1 and 10 mM within several minutes using a real-time, stirred batch method. This system offers the potential for fast, simple, cost-effective biosensors for the analysis of
many substances of environmental, biomedical and pharmaceutical concern
Organophosphorous Pesticide Detection in Olive Oil by Using a Miniaturized, Easy-to-Use, and Cost-Effective Biosensor Combined with QuEChERS for Sample Clean-Up
En el laboratorio de curtición de pieles de la Facultad de Ciencias Pecuarias de la ESPOCH, se evaluó la obtención de napa de cordero para vestimenta con la aplicación de tres porcentajes de anilina, modelados bajo un Diseño Completamente al Azar en arreglo bifactorial empleando 45 unidades experimentales. En la evaluación de las resistencias físicas se reportaron diferencias altamente significativas (P < 0.05); registrándose los mejores resultados para adherencia (83,27%), desgarro (71,87 N/cm2) y porcentaje de elongación (86,73%), con la aplicación de 5% de anilina (T3). Respuestas similares se identificaron al evaluar las calificaciones sensoriales ya que se establecieron las mejores respuestas con la aplicación del 5% de anilina (T3), para blandura (4,53 puntos), redondez y efecto resorte (4,40 puntos). Finalmente en el análisis del beneficio costo se determinaron los mejores resultados con la adición de 5% de anilina por cuanto el beneficio costo fue de 1.23 que quiere decir que por cada dólar invertido se espera una rentabilidad del 23%. Por lo que se recomienda aplicar a la fórmula del teñido el 5% de anilina (T3), ya que se elevan significativamente las resistencias físicas y calificaciones sensoriales obteniéndose por lo tanto mayor rentabilidad de la napa de cordero
Aflatoxin M1 determination in raw milk using a flow-injection immunoassay system
A flow-injection immunoassay (FI-IA) method with amperometric detection for aflatoxin M1 (AFM1) determination in milk has been developed. The first step consists in an incubation of the sample containing AFM1 (Ag) with fixed amounts of anti-AFM1 antibody (Ab) and of the tracer (Ag*, AFM1 covalently coupled to HRP) until equilibrium is reached. In this mixture a competition occurs between Ag and Ag* for the Ab. The mixture is then injected into a flow system where the separation of the free tracer (Ag*) and the antibody-bound tracer (AbAg*) is performed in a column with immobilized Protein G. The antigen-antibody complexes are retained in the column due to the high affinity of the Protein G for the antibody. The activity of the eluted enzyme label is then amperometrically detected. The immunoassay was optimised relative to conditions for antibody-antigen incubation (pH, incubation time, ionic strength, temperature) and enzymatic label detection. This method showed a dynamic concentration range between 20 and 500 ppt AFM1, a low detection limit (11 ppt), good reproducibility (RSD < 8%) and a high throughput (six samples per hour in triplicate). Different milk samples were analysed and the results were in good agreement with those obtained by HPLC using the AOAC 2000.08 method. © 2004 Elsevier B.V. All rights reserved
A fully-printed electrochemical platform for assisted colorimetric detection of phosphate in saliva: Greenness and whiteness quantification by the AGREE and RGB tools
Herein, we report the environmental impact quantification of a newly developed fully printed electrochemical
device to assist a colorimetric detection of phosphate in saliva. The evaluation of the analytical procedure was per formed according to the principles of Green Analytical Chemistry and White Analytical Chemistry. The standard
method for phosphate detection relies on a reaction between phosphate and molybdate in presence of antimony
potassium tartrate and ascorbic acid, using strong acid conditions and high volumes of reagents (100–500 mL).
To deliver an eco-friendly method, we have combined a screen-printed electrode with a liquid electrolyte battery
and inkjet-printed conductive paths to develop a fully printed device on a flexible polymer substrate avoiding the
use of ascorbic acid and using a small amount of reagents. The printed sensor was first developed and optimized
for phosphate detection in saliva, allowing for a detection limit equal to 26 μM and satisfactory repeatability
(relative standard deviation value of 7.5%). Finally, the AGREE and the RGB assessment tools were applied for a
quantitative evaluation of the proposed sensor and reference method, in agreement with the Green Analytical and
White Analytical principles. The results demonstrated the lower environmental impact of the proposed sensor,
as well as the suitability of this novel approach for phosphate detection in saliv
- …