619 research outputs found

    PICKING THE BEST NOVEL ORAL ANTICOAGULANT FOR ATRIAL FIBRILLATION: EVIDENCE FROM A WARFARIN-CONTROLLED NETWORK META-ANALYSIS

    Get PDF
    Warfarin is a mainstay atrial ibrillation (AF) treatment, yet it has a narrow therapeutic window. Novel agents have been successfully tested against warfarin, yet no direct comparison among them is available. We thus performed a pair-wise and warfarin-adjusted network metaanalyses of novel oral anticoagulants for AF

    Mismatch between morphological and functional assessment of the length of coronary artery disease

    Get PDF
    Background: Morphological evaluation of coronary lesion length is a paramount step during invasive assessment of coronary artery disease. Likewise, the extent of epicardial pressure losses can be measured using longitudinal vessel interrogation with fractional flow reserve (FFR) pullbacks. We aimed to quantify the mismatch in lesion length between morphological (based on quantitative coronary angiography, QCA, and optical coherence tomography, OCT) and functional evaluations. Methods: This is a prospective and multicenter study of patients evaluated by QCA, OCT and motorized fractional flow reserve pullbacks (mFFR). The difference in lesion length between the functional and anatomical evaluations was referred to as FAM. Results: 117 patients (131 vessels) were included. Median lesion length derived from angiography was 16.05 mm [11.40–22.05], from OCT was 28.00 mm [16.63–38.00] and from mFFR 67.12 mm [25.38–91.37]. There was no correlation between QCA and mFFR lesion length (r = 0.124, 95% CI -0.168-0.396, p = 0.390). OCT lesion length did correlate with mFFR (r = 0.469, 95% CI 0.156–0.696, p = 0.004). FAM was strongly associated with the improvement in vessel conductance with percutaneous coronary intervention (PCI), higher mismatch was associated with lower post-PCI FFR. Conclusions: Lesion length assessment differs between morphological and functional evaluations. The morphological-functional mismatch in lesion length is frequent, and influences the results of PCI in terms of post-PCI FFR. Integration of the extent of pressure losses provides clinically relevant information that may be useful for clinical decision-making concerning revascularization strategy

    Does the inflow velocity profile influence physiologically relevant flow patterns in computational hemodynamic models of left anterior descending coronary artery?

    Get PDF
    Patient-specific computational fluid dynamics is a powerful tool for investigating the hemodynamic risk in coronary arteries. Proper setting of flow boundary conditions in computational hemodynamic models of coronary arteries is one of the sources of uncertainty weakening the findings of in silico experiments, in consequence of the challenging task of obtaining in vivo 3D flow measurements within the clinical framework. Accordingly, in this study we evaluated the influence of assumptions on inflow velocity profile shape on coronary artery hemodynamics. To do that, (1) ten left anterior descending coronary artery (LAD) geometries were reconstructed from clinical angiography, and (2) eleven velocity profiles with realistic 3D features such as eccentricity and differently shaped (single- and double-vortex) secondary flows were generated analytically and imposed as inflow boundary conditions. Wall shear stress and helicity-based descriptors obtained prescribing the commonly used parabolic velocity profile were compared with those obtained with the other velocity profiles. Our findings indicated that the imposition of idealized velocity profiles as inflow boundary condition is acceptable as long the results of the proximal vessel segment are not considered, in LAD coronary arteries. As a pragmatic rule of thumb, a conservative estimation of the length of influence of the shape of the inflow velocity profile on LAD local hemodynamics can be given by the theoretical entrance length for cylindrical conduits in laminar flow conditions

    Design Study of a Novel Positron Emission Tomography System for Plant Imaging

    Get PDF
    Positron Emission Tomography is a non-disruptive and high-sensitive digital imaging technique which allows to measure in-vivo and non invasively the changes of metabolic and transport mechanisms in plants. When it comes to the early assessment of stress-induced alterations of plant functions, plant PET has the potential of a major breakthrough. The development of dedicated plant PET systems faces a series of technological and experimental difficulties, which make conventional clinical and preclinical PET systems not fully suitable to agronomy. First, the functional and metabolic mechanisms of plants depend on environmental conditions, which can be controlled during the experiment if the scanner is transported into the growing chamber. Second, plants need to be imaged vertically, thus requiring a proper Field Of View. Third, the transverse Field of View needs to adapt to the different plant shapes, according to the species and the experimental protocols. In this paper, we perform a simulation study, proposing a novel design of dedicated plant PET scanners specifically conceived to address these agronomic issues. We estimate their expected sensitivity, count rate performance and spatial resolution, and we identify these specific features, which need to be investigated when realizing a plant PET scanner. Finally, we propose a novel approach to the measurement and verification of the performance of plant PET systems, including the design of dedicated plant phantoms, in order to provide a standard evaluation procedure for this emerging digital imaging agronomic technology

    External electrical and pharmacological cardioversion for atrial fibrillation, atrial flutter or atrial tachycardias:a network meta-analysis

    Get PDF
    BackgroundAtrial fibrillation (AF) is the most frequent sustained arrhythmia. Cardioversion is a rhythm control strategy torestore normal/sinus rhythm, and can be achieved through drugs (pharmacological) or a synchronized electricshock (electrical cardioversion).ObjectivesTo assess the efficacy and safety of pharmacological and electrical cardioversion for AF.Search methodsWe searched CENTRAL, MEDLINE, Embase, Conference Proceedings Citation Index-Science (CPCI-S) andthree trials registers (ClinicalTrials.gov, WHO ICTRP and ISRCTN) on 14 February 2023.Selection criteriaWe included randomised controlled trials (RCTs) at individual patient level. Patient populations were aged ≥18years with AF of any type and duration, atrial flutter or other sustained related atrial arrhythmias, not occurring asa result of reversible causes.Data collection and analysisWe used standard Cochrane methodology to collect data and performed a network meta-analysis using thestandard frequentist graph-theoretical approach using the netmeta package in R. We used GRADE to assess thequality of the evidence which we presented in in our summary of findings with a judgement on certainty. Wecalculated differences using risk ratios (RR) and 95% confidence intervals (CI) as well as ranking treatmentsusing a P-score. We assessed clinical and statistical heterogeneity and split the networks for the primaryoutcome and acute procedural success due to concerns about violating the transitivity assumption.Main resultsWe included 112 RCTs (139 records), from which we pooled data from 15,968 patients. Average age was 47 to72 years and proportion of male patients was 38%-92%.79 trials were considered high risk of bias for at least one domain, 32 had no high risk of bias domains, but hadat least one domain classified as uncertain risk, and one study was considered low risk for all domains.For paroxysmal AF (35 trials), when compared to Placebo, AA/AP BTE incremental cardioversion (RR: 2.42;95%CI 1.65 to 3.56), quinidine (RR: 2.23; 95%CI 1.49 to 3.34), ibutilide (RR: 2.00; 95%CI 1.28 to 3.12),propafenone (RR: 1.98; 95%CI 1.67 to 2.34), amiodarone (RR: 1.69; 95%CI 1.42 to 2.02), sotalol (RR: 1.58;95%CI 1.08 to 2.31) and procainamide (RR: 1.49; 95%CI 1.13 to 1.97) likely result in a large increase inmaintenance of sinus rhythm until hospital discharge or end of study follow-up (certainty of evidence: moderate).The effect size was larger for AA/AP incremental and was progressively smaller for the subsequent interventions.Despite low certainty of evidence Antazoline may result in a large increase (RR: 28.60; 95%CI 1.77 to 461.30) inthis outcome. Similarly, low certainty evidence suggests a large increase on this outcome for flecainide (RR: 2.17;95%CI 1.68 to 2.79), vernakalant (RR: 2.13; 95%CI 1.52 to 2.99), and magnesium (RR: 1.73; 95%CI 0.79 to 3.79)on this outcome.For persistent AF (26 trials), one network was created for electrical cardioversion and showed that whencompared to AP BTE incremental energy with patches, AP BTE maximum energy with patches (RR 1.35, 95%CI1.17 to 1.55) likely results in large increase and Active compression AP BTE incremental energy with patches(RR: 1.14, 95%CI 1.00 to 1.131) likely results in an increase in maintenance of sinus rhythm at hospital dischargeor end of study follow-up (certainty of evidence: high). Use of AP BTE incremental with paddles (RR: 1.03, 95%CI0.98 to 1.09; certainty of evidence: low) may lead to a little increase, and AP MDS Incremental paddles (RR: 0.95,95%CI 0.86 to 1.05; certainty of evidence: low) may lead to a little decrease in efficacy. On the other hand, APMDS incremental energy using patches (RR: 0.78, 95%CI 0.70 to 0.87), AA RBW incremental energy withpatches (RR: 0.76, 95%CI 0.66 to 0.88), AP RBW incremental energy with patches (RR: 0.76, 95%CI 0.68 to0.86), AA MDS incremental energy with patches (RR: 0.76, 95%CI 0.67 to 0.86) and AA MDS incremental energywith paddles (RR: 0.68, 95%CI 0.53 to 0.83) probably result in a decrease on this outcome when compared to APBTE incremental energy with patches (certainty of evidence: moderate). The network for pharmacologicalcardioversion showed that Bepridil (RR: 2.29, 95%CI 1.26 to 4.17) and Quindine (RR: 1.53, (95%CI 1.01 to 2.32)probably result in large increase in maintenance of sinus rhythm at hospital discharge or end of study follow-upwhen compared to amiodarone (certainty of evidence: moderate). Dofetilide (RR: 0.79, 95%CI 0.56 to 1.44),Sotalol (RR: 0.89, 95%CI 0.67 to 1.18), Propafenone (RR: 0.79, 95%CI 0.50 to 1.25) and Pilsicainide (RR: 0.39,95%CI 0.02 to 7.01) may result in a reduction of this outcome when compared to amiodarone, but certainty ofevidence is lowFor atrial flutter (14 trials) a network could be created only for antiarrhythmic drugs. Using Placebo as thecommon comparator, ibutilide (RR: 21.45, 95%CI 4.41 to 104.37), propafenone (RR: 7.15, 95%CI 1.27 to 40.10),dofetilide (RR: 6.43, 95%CI 1.38 to 29.91), and sotalol (RR: 6.39, 95%CI 1.03 to 39.78) probably result in a largeincrease in maintenance of sinus rhythm at hospital discharge or end of study follow-up (certainty of evidence:moderate), and procainamide (RR: 4.29, 95%CI 0.63 to 29.03), flecainide (RR 3.57, 95%CI 0.24 to 52.30) andvernakalant (RR: 1.18, 95%CI 0.05 to 27.37) may result in a large increase of maintenance of sinus rhythm athospital discharge or end of study follow-up at (certainty of evidence: low) All tested electrical cardioversionstrategies for atrial flutter had very high efficacy (97.9% to 100%).Mortality (14 deaths) and Stroke or systemic embolism (3 events) at 30 days was extremely low.Data on quality of life were scarce and of uncertain clinical significance. No information was available regardingheart failure readmissions. Data on duration of hospitalization was scarce, low quality, & could not be pooled.Authors' conclusionsDespite the low quality of evidence, this systematic review provides important information on electrical andpharmacological strategies to help patients and physicians deal with AF and atrial flutter.Assessing the patient comorbidity profile, antiarrhythmic drug onset of action & side effect profile vs. need for aphysician with experience in sedation, or anaesthetics support, for electrical cardioversion are key aspects whenchoosing the cardioversion method

    Intrafollicular expression of matrix metalloproteinases and their inhibitors in normally ovulating women compared with patients undergoing in vitro fertilization treatment

    Get PDF
    OBJECTIVE: To assess possible differences in the activity of matrix metalloproteinases (MMPs), MMP-2 and MMP-9, and their inhibitors, the tissue inhibitors of MMPs, TIMP-1 and TIMP-2, in follicular fluid (FF) of women undergoing in vitro fertilization (IVF) treatment and of normally ovulating women. DESIGN: Prospective study. METHODS: MMP-2 and MMP-9 activity was analyzed by gelatin zymography and MMP-2, MMP-9, TIMP-2, TIMP-1 and 17beta-estradiol levels were measured in FF by ELISA. RESULTS: We found significantly reduced MMP levels in FF of women undergoing IVF treatment when compared with those of normally ovulating women. In contrast, the TIMP-1 levels were found significantly increased in FF from IVF patients vs normally ovulating women. No significant differences were found for TIMP-2 between the two groups. CONCLUSIONS: These findings underline a marked difference in MMPs and their inhibitors in the IVF women and the control group. Therefore we assume MMPs depend on hormonal steroidogenesis modulation induced by the gonadotropin protocol for IVF treatment

    Dopaminergic-GABAergic interplay and alcohol binge drinking

    Full text link
    © 2019 Elsevier Ltd The dopamine D 3 receptor (D 3 R), in the nucleus accumbens (NAc), plays an important role in alcohol reward mechanisms. The major neuronal type within the NAc is the GABAergic medium spiny neuron (MSN), whose activity is regulated by dopaminergic inputs. We previously reported that genetic deletion or pharmacological blockade of D 3 R increases GABA A α6 subunit in the ventral striatum. Here we tested the hypothesis that D 3 R-dependent changes in GABA A α6 subunit in the NAc affect voluntary alcohol intake, by influencing the inhibitory transmission of MSNs. We performed in vivo and ex vivo experiments in D 3 R knockout (D 3 R −/− ) mice and wild type littermates (D 3 R +/+ ). Ro 15-4513, a high affinity α6-GABA A ligand was used to study α6 activity. At baseline, NAc α6 expression was negligible in D 3 R +/+ , whereas it was robust in D 3 R −/− ; other relevant GABA A subunits were not changed. In situ hybridization and qPCR confirmed α6 subunit mRNA expression especially in the NAc. In the drinking-in-the-dark paradigm, systemic administration of Ro 15-4513 inhibited alcohol intake in D 3 R +/+ , but increased it in D 3 R −/− ; this was confirmed by intra-NAc administration of Ro 15-4513 and furosemide, a selective α6-GABA A antagonist. Whole-cell patch-clamp showed peak amplitudes of miniature inhibitory postsynaptic currents in NAc medium spiny neurons higher in D 3 R −/− compared to D 3 R +/+ ; Ro 15-4513 reduced the peak amplitude in the NAc of D 3 R −/− , but not in D 3 R +/+ . We conclude that D 3 R-dependent enhanced expression of α6 GABA A subunit inhibits voluntary alcohol intake by increasing GABA inhibition in the NAc
    • …
    corecore